2-2
An Overview of the Converter
512C Series Converter
Control Features
Speed
Control
Control Action
Closed Loop with Proportional Integral Control
and Adjustable Stability
Speed Feedback
Armature Voltage Tachogenerator
100% Load Regulation
2 % Typical
0.1 % Typical
Maximum Torque/Speed
Range
20:1 100:1
Overload
150% for 60 seconds.
Torque
Control Action
Closed Loop with Proportional Integral Control
Control
Accuracy 2
%
Overspeed Inherent
Overload
None 100% Continuous (consideration must be
given to motor when operating at low speed)
Inputs/
Outputs
Analogue Inputs
Setpoint Ramp
0 to +10V
100Kohm
Auxiliary
Speed
Setpoint
0 to +10V
100Kohm
Current Limit
0 to +7.5V 50Kohm
Tachogenerator
Input
0 to
+350Vdc
110Kohm
Analogue Outputs
Speed
0 to +10V
5mA
Current
(SW8 Off)
0 to +5V
(0 to Idc)
5mA
Current
(SW8 On)
0 to +5V
(0 to Ical)
5mA
Setpoint Ramp
0 to +10V
5mA
Total Setpoint
0 to +10V
5mA
+10V
Reference
+10V
5mA
-10V Reference
- 10V
5mA
Digital Inputs
Run
+10 to
+24V
100Kohm
Stall
Override
+10
100Kohm
Digital Outputs
Health
+24V
50mA Source
Zero Speed or
Setpoint
+24V 50mA
Source
www.comoso.com