background image

WARNING

FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL
INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users
having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to
the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the
products and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its
subsidiaries at any time without notice.

How to Order Options

High Temperature Seals – Add the suffix –HT to the end of the part number.  For service up to 250 

°

F (121 

°

C).  Add the

suffix –HT4 to the end of the part number for service up to 400 

°

F (204 

°

C).  NOTE:  The –HT4 option is only available on

series 62 and 63 90

°

 models.  Example:  2F-HB4LK-BN-SS-61AD-HT.

Low Temperature Seals – Add the suffix –LT to the end of the part number.  Example:  4A-MB4LPFA-SS-61SAC-LT.
Accessories –
 Add one of the following suffixes to the end of the part number.  Example:  16F-SB16L-PF-T-SS-63AC-3-2D.

Dual Mount Actuator – Add –DVM as a suffix to the end of the part number.  Example:  6F-B6LPKC-SS-61AC-2-DVM.  With
DVM dual mount valve options, the following are standard arrangements:  Two-way valves are provided in their failed position
(in their closed position with AD actuators).  Three-way valves are provided as shown below.  Contact the factory for details on
other available options.

How to Order Mounting Bracket Kits

Add the valve series and actuator model designation as a suffix to MK-.  Example:  MK-MB4L-61S.  Describes a mounting kit
for a MB Series ball valve with a 61S Series actuator.

Suffix

                              Accessory

Single Option

-1A

Breather Block

-1B

Solenoid Valve, (NEMA 4, 120 VAC)

-1C

Solenoid Valve, (NEMA 7, 120 VAC)

-1D

Solenoid Valve, (NEMA 4, 24 VDC)

-1E

Solenoid Valve, (NEMA 7, 24 VDC)

-1F

Solenoid Valve, (NEMA 4, 240 VAC)

-1G

Solenoid Valve, (NEMA 7, 240 VAC)

-1H

Limit Switch – Two SPDT switches with mounting kit

Double Option

-2A

Breather Block, Solenoid Valve, (NEMA 4, 120 VAC)

-2B

Breather Block, Solenoid Valve, (NEMA 7, 120 VAC)

-2C

Breather Block, Solenoid Valve, (NEMA 4, 24 VDC)

-2D

Breather Block, Solenoid Valve, (NEMA 7, 24 VDC)

-2E

Breather Block, Solenoid Valve, (NEMA 4, 240 VAC)

-2F

Breather Block, Solenoid Valve, (NEMA 7, 240 VAC)

-2G

Limit Switch, Solenoid Valve, (NEMA 4, 120 VAC)

-2H

Limit Switch, Solenoid Valve, (NEMA 7, 120 VAC)

-2J

Limit Switch, Solenoid Valve, (NEMA 4, 24 VDC)

-2K

Limit Switch, Solenoid Valve, (NEMA 7, 24 VDC)

-2L

Limit Switch, Solenoid Valve, (NEMA 4, 240 VAC)

-2M

Limit Switch, Solenoid Valve, (NEMA 7, 240 VAC)

Triple Option

-3A

Breather Block, Limit Switch, Solenoid Valve, (NEMA 4, 120 VAC)

-3B

Breather Block, Limit Switch, Solenoid Valve, (NEMA 7, 120 VAC)

-3C

Breather Block, Limit Switch, Solenoid Valve, (NEMA 4, 24 VDC)

-3D

Breather Block, Limit Switch, Solenoid Valve, (NEMA 7, 24 VDC)

-3E

Breather Block, Limit Switch, Solenoid Valve, (NEMA 4, 240 VAC)

-3F

Breather Block, Limit Switch, Solenoid Valve, (NEMA 7, 240 VAC)

© Copyright 2000, Parker Hannifin Corporation.  All Rights Reserved.

Offer of Sale

The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by
the provisions stated in the “Offer of Sale” located in Catalog 4110-U Needle Valves (U Series).

11

Pneumatic Actuators

Parker Hannifin Corporation
Instrumentation Valve Division
Jacksonville, Alabama

Содержание 4123-PA

Страница 1: ...Pneumatic Actuators Catalog 4123 PA Revised March 2000 ...

Страница 2: ...sive gas or light hydraulic oil Aluminum alloy body construction with two component polyurethane coating Manual override Specifications Operating Pressure 90 Models 40 to 120 psig 2 8 to 8 3 bar maximum AC Normally Closed Spring Return AD Double Acting AO Normally Open Spring Return 180 Models 80 psig 5 5 bar maximum ACX Spring Return ADX Double Acting Temperature Range 4 F to 175 F 20 C to 79 C O...

Страница 3: ...59 40 4 4 25 108 0 4 65 118 1 68ADX 7 28 184 9 6 33 160 8 5 31 134 9 2 09 53 1 5 61 142 5 5 31 134 9 68ACX 8 5 215 9 6 33 160 8 5 31 134 9 2 09 53 1 5 61 142 5 5 31 134 9 69AD 11 14 283 0 6 65 168 9 5 63 143 0 1 99 50 5 5 04 128 0 5 63 143 0 69AC O 14 17 359 9 6 65 168 9 5 63 143 0 1 99 50 5 5 04 128 0 5 63 143 0 C1 Single Mount C2 Dual Mount 61SAD 61SAC O 61SADX 61SACX Dim Inch mm Inch mm Inch mm...

Страница 4: ...or 61SAO 61AC 2 or 61SAC B6LSPKR 61AD or 61SAD 61AO 2 or 61SAO 61AC 2 or 61SAC B6XJ 61ADX or 61SADX 61ACX 2 or 61SACX 61ACX 2 or 61SACX B6XJ2 61ADX or 61SADX 61ACX 2 or 61SACX 61ACX 2 or 61SACX B6XS2 61ADX or 61SADX 61ACX 2 or 61SACX 61ACX 2 or 61SACX B6XPKR 61ADX or 61SADX 61ACX 2 or 61SACX 61ACX 2 or 61SACX B6XSPKR 61ADX or 61SADX 61ACX 2 or 61SACX 61ACX 2 or 61SACX B8LJ 61AD 61AO 2 61AC 2 B8LJ2...

Страница 5: ...62AD 61AD 63AC 3 63AC 3 SB16 61ADX 61ADX 68ACX 8 68ACX 8 SB20 63AD 63AD 69AC 3 66AC 4 SB24 63AD 63AD 69AC 3 66AC 4 SB24 68ADX 68ADX SB32 66AD 65AD 69AC 3 69AC 3 SB32 68ADX PF Seats PF Seats PF Seats SB8 61AD 61AD 62AC 3 61AC 2 SB8 61ADX 61ADX 64ACX 8 61ACX 2 SB8 61ADX 61ADX 68ACX 8 64ACX 12 SB12 61AD 61AD 62AC 3 62AC 3 SB12 61ADX 61ADX 64ACX 8 64ACX 8 SB12 64ADX 61ADX 68ACX 8 68ACX 8 SB16 62AD 61A...

Страница 6: ... following procedure 1 Find the valve torque from the appropriate curve by using the differential pressure Locate the differential pressure on the horizontal axis of the chart and move up until you arrive at the appropriate valve size Transfer the intersecting point across to the vertical axis of the graph and read the required torque 2 Multiply this torque by the service and media application fac...

Страница 7: ... Pressure psig Torque In lb Torque Nm SB16 SB20 600 500 400 300 200 0 100 SB32 SB24 68 57 45 34 23 11 0 SB12 SB8 0 14 28 41 55 0 200 400 600 800 Differential Pressure bar Differential Pressure psig Torque In lb Torque Nm 250 200 150 100 50 0 28 17 11 0 6 22 SB32 SB24 SB16 SB8 SB12 0 17 34 51 68 86 103 0 250 500 750 1000 1250 1500 Differential Pressure bar Differential Pressure psig Torque In lb To...

Страница 8: ...22 70 3 117 13 2 3 10 1 1 178 20 1 347 39 2 515 58 2 175 19 8 65 4 72 8 1 240 27 1 408 46 1 234 26 4 5 133 15 0 301 34 0 292 33 0 6 26 2 9 195 22 0 351 39 7 2 192 21 7 441 49 8 690 78 0 939 106 1 161 18 2 3 43 4 9 293 33 1 542 61 2 790 89 3 242 27 3 66 4 143 16 2 392 44 3 641 72 4 323 36 5 5 244 27 6 492 55 6 403 45 5 6 95 10 7 344 38 9 484 54 7 2 406 45 9 952 107 6 1498 169 2 2043 230 8 361 40 8 ...

Страница 9: ...25 6 262 29 6 Weight Operating Air Consumption Air Consumption Bore Stroke AD AC Time in3 cc Series Inch mm Inch mm lb kg lb kg sec Port A Port B Port A Port B 61 1 8 45 7 1 0 25 4 1 9 0 9 2 4 1 1 0 8 4 5 5 7 73 8 93 4 61S 1 8 45 7 1 0 25 4 1 4 0 7 1 7 0 8 0 8 6 1 3 1 100 0 50 0 64 3 2 81 3 0 7 17 8 5 5 2 5 6 4 2 9 1 5 16 0 23 0 262 3 377 0 68 4 3 109 2 1 0 25 4 11 6 5 3 13 6 6 2 2 8 37 0 49 0 606...

Страница 10: ... Assembled Add the actuator model designation as a suffix to the ball valve part number Example 4Z B6LJ2 SSP 61AC 2 Describes a B6 ball valve with a normally closed actuator For Field Assembly Simply specify the actuator Example 65AC 3 Mounting bracket kits are required when mounting actuators to valves Options High Temperature Seals Extends the high temperature from 175 F 79 C to 250 F 121 C and ...

Страница 11: ...on with AD actuators Three way valves are provided as shown below Contact the factory for details on other available options How to Order Mounting Bracket Kits Add the valve series and actuator model designation as a suffix to MK Example MK MB4L 61S Describes a mounting kit for a MB Series ball valve with a 61S Series actuator Suffix Accessory Single Option 1A Breather Block 1B Solenoid Valve NEMA...

Страница 12: ...ama Highway 21 North Jacksonville AL 36265 9681 Phone 256 435 2130 Fax 256 435 7718 www parker com IVD Catalog 4123 PA 20M 03 00 INSTRUMENTATION VALVE DIVISION AN ISO 9001 FACILITY Accredited by the Dutch Council for Certification Quality Systems Registrars Inc QSR 202 ...