EN
| User Manual
Annex with technical documentation
BSP-MT 10-95/D3
45
Technical data
Operating Range
Site Selection
frost-free indoor installation in a
non-hazardous environment
Ambient temperature
1,5 to 50 °C (24,7 to 122 °F)
Compressed air inlet temperature
25 to 50 °C (68 to 122 °F)
Max. operating pressure
16 bar
e
Min. operating pressure
5 bar
e
Medium
Compressed air
Fluid group
2
Electrical connection
Mains voltage, standard
230 V, 50-60 Hz
Alternative voltage
115 V, 50-60 Hz and 24 V DC
Protection class
IP65
Please note type plate and attached electrical circuit diagram!
Performance details
Type
Volumetric
fl ow¹ in
m3/h
Nominal
pipe
2
1. Upstream
fi lter
2. Upstream
fi lter
Downstream
fi lter
Nominal
Pressure
in bare
Nominal
temperat.
°C
BSP-MT 10
158
1
AOP025EGFI AAP025EGMI
AOP025EGMI
16
50
BSP-MT 15
210
1
AOP025EGFI AAP025EGMI
AOP025EGMI
16
50
BSP-MT 20
274
1
AOP025EGFI AAP025EGMI
AOP025EGMI
16
50
BSP-MT 25
371
1 1/2
AOP030GGFI AAP030GGMI
AOP030GGMI
16
50
BSP-MT 35
484
1 1/2
AOP030GGFI AAP030GGMI
AOP030GGMI
16
50
BSP-MT 45
589
1 1/2
AOP035GGFX AAP035GGMX
AOP035GGMX
16
50
BSP-MT 60
839
2
AOP040HGMX AAP040HGFX
AOP040HGMX
16
50
BSP-MT 75
1129
2
AOP040HGMX AAP040HGFX
AOP040HGMX
16
50
BSP-MT 95
1371
2 ½
AOP045IGFX AAP045IGFX
AOP045IGMX
16
50
1
. m3/h, relating to 1 bara and 20 °C at the compressor suction capacity. Subsequently com-
pressed to 13 bare and 35°C inlet temperature to the dryer at 100 % relative humidity – for
pressure dewpoints of -25 °C and -40 °C.
2
. In accordance with DIN ISO 228 (BSP-P)
Noise emission
Noise level : +3 dB (A)
1
65 – 95 dB(A)
1
.. relative to free fi eld measurement, 1 m surr. fi eld
Dimensions
Please heed to the dimensional drawings and the according table containing dimensions
and weight on page 53.