EN
| User Manual
Maintenance and repair of the dryer
BSP-MT 10-95/D3
35
Upstream and down-
stream fi lter
Please see the enclosed operating instructions for the attached fi lters.
Maintenance work has to be carried out as specifi ed in this document.
When carrying out any maintenance work, comply with the following safety instructions:
Danger!
There is a very considerable risk of personal injury, when carrying out work on
the activated and pressurised dryer.
Danger!
Before commencing any maintenance tasks always shut down the dryer as
described on page
30
!
Warning against electrical voltage!
Only qualifi ed specialist personnel may carry out work on the electrical system!
Instructions for use of the dongle
If the message
SEr
, is displayed on the display of the Multitronic controller, the dryer is due
for servicing. The message appears, fl ashing every 60 seconds, once the preset number of
operating hours (e. g. 8000 oh) has been reached. After maintenance has been carried out,
you can use the dongle to reset the counter to 0 and delete the message from the display. A
dongle is enclosed with every service kit. Each dongle can only be used once.
Switch off the controller. Caution! The electric line is still live. Do not touch live parts!
Open the lid to the Multitronic controller. The circuit board in housed underneath it.
Slot the dongle into the dongle interface X9 PC.
Press and hold the reset key S3.
Switch on the controller. The following appears in the display:
for a short time
0.SET
then fl ashing
OFF
The service counter is then reset to 0.
If the following appears in the display
for a short time
FAIL
then fl ashing
OFF
this means that the dongle has already been used once and cannot be used again.
Switch off the controller again and remove the dongle.
Dispose of the unusable dongle and use a new one.
Содержание BSP-MT 10-95/D3
Страница 2: ......
Страница 53: ...EN User Manual Annex with technical documentation BSP MT 10 95 D3 51 Regeneration in B1 and adsorption in B2 ...
Страница 54: ...EN User Manual Annex with technical documentation 52 BSP MT 10 95 D3 Flow diagram ...
Страница 55: ...EN User Manual Annex with technical documentation BSP MT 10 95 D3 53 Dimensional drawing ...
Страница 56: ...EN User Manual 54 BSP MT 10 95 D3 ...
Страница 57: ...EN User Manual BSP MT 10 95 D3 55 ...
Страница 58: ...EN User Manual 56 BSP MT 10 95 D3 ...
Страница 59: ......