3 / 14

   ATT060-090  

4 Commissioning

4.1 Preliminary checks

Before starting the dryer, make sure: 

•  installation was carried out according that given in the section 9.2;
•  the air inlet valves are closed and that there is no air fl ow through 
the dryer;
•  the power supply is correct.

4.2 Starting

Before starting the dryer follow the following instruction:

•  Switch the power on by turning the MAIN SWITCH (IG)  

&

  to 

“ ON”.
•  Shows the “MAIN SCREEN VIEW on display. 

Start the air compressor.
Start-up procedure dryer:

Press 
to enter on “Main Menu”

- - -Main Menu - - -

START/STOP

USER SETTINGS

SERVICE

INFORMATION

Select

 START/STOP

and confi rm with 

Enter

- - -Main Menu - - -

START/STOP

USER SETTINGS

SERVICE

INFORMATION

Select:

NORMAL START/STOP 

and confi rm with  

Enter

- On/Off Menu -

NORMAL START/STOP

STOP DIRECTLY

Confi rm 

START

, for the start-up

ENABLE UNIT RUNNING

STOP

Compressed 

Inlet Air” pressure 

insuffi

  cient, dryer blocked.

INSUFFICIENT AIR PRESSURE

!Y

 Attention: Th

  e  air compressor must be started before the dryer. 

Otherwise you may damage the electric resistance.

Th

 e fi rst start-up is in “Forced Regeneration” on default. 

Th

  e unit works for a complete cycle (2 columns), aft er switches to nor-

mal working.

It is recommended to complete this type of starting with the air 

outlet valve closed, to preserve the correct operation of the desiccant 
bed.

4.3 Operation

Leave the dryer in working during the period of working of the air com-
pressor.

• Th

  e dryer works automatically, calibrations are not required on the 

fi eld;
•  if there are excessive and unexpected air fl ows, by-pass to avoid 
overloading the dryer.

4.4  Operation with Dew point control

In the case of work loads below the nominal or if you want diff erent dew 
point of -40 ° C, it is possible to work in 

Dew Point Control

. Th

 e system 

automatically controls the time of the cycles of operation to obtain and 
maintain the predetermined dew point, with the result of energy saving 
in case of work with partial loads.
Procedure to set “dew point control”.

Press Prg  to enter on main menu 
Using 

Up

 and 

Down

 select

USER SETTINGS”

Press 

Enter

 to confi rm.

- - -Main Menu - - -

START/STOP

USER SETTINGS

SERVICE

INFORMATION

Shows the “User settings menu

- User Settings Menu - 

DRYER SETTINGS

DATE/TIME

BMS

MOISTURE DRAIN

OTHER

LANGUAGE

Using 

Up

 and 

Down

 select

“DRYER SETTINGS”

Press 

Enter

 to confi rm.

- User Settings Menu - 

DRYER SETTINGS

DATE/TIME

BMS

MOISTURE DRAIN

OTHER

LANGUAGE

Using 

Up

 and 

Down

 select

the parameter.
Press 

Enter

 to confi rm..

U1 - DEWP.SET (°C):                       -40

U2 - PRESSURE (barg):                   07 

U3 - MODE: Forced Rig.
U4 - ALARM RELAY MODE:
by: ALARMS & WARNINGS

U6 -  DPM:                NO FITTED

Select the parameter 

U1- DEWP.SET

 (°C) and set the value you need. 

Press

 Enter 

to confi rm. see Table 1 for identifying the correct value 

to be set

Select the parameter 

U6- DPM

: set the mode 

FITTED.

 Press

 Enter 

to confi rm.

 

Table 1

Dew
Point

Application

-70°C

Request for a very low dew point.

-40°C

Request for a very low dew point.
(depend on the type of the process.).

-20°C

Request for a low dew point. 
When the pipes air compressed are in external environ-
ment and the minimum winter ambient temperatures are 
above -10 to -15 ° C.

-10°C

Request for a low dew point.
When the pipes air compressed are in external environ-
ment and the minimum winter ambient temperatures are 
above  -5°C.

0°C

Request for a dew point standard.
When the pipes air compressed are in external environ-
ment and the minimum winter ambient temperatures are 
above  10°C.

Important: for correct readings, the Dew point sensor must work at a 
precise air fl ow, which is adjusted by a fl ow meter (no. 33).
CORRECT CALIBRATION: LEVEL    2 ÷ 5     liters/minutes
To ensure optimal Dew point  sensor operation, comply with the 
maintenance instructions given in para. 6.4. 
In this regard, the sensor connection is fi tted with a shut-off  valve to 
facilitate maintenance

Содержание Antares ATT Series

Страница 1: ...ATT060 ATT090 50Hz DATE 30 03 2017 Rev 20 CODE 398H272985 IT Manuale d uso EN User Manual ES Manual de uso DE Benutzer Handbuch ATT Antares Tandem Dryer Antares Tandem Dryer...

Страница 2: ......

Страница 3: ...omunque in modo che non venga generata alcuna situazione di rischio I rischi che non stato possibile eliminare in fase di progettazione sono riportati nella tabella seguente Parte Considerata Rischi R...

Страница 4: ...ento elettrico Usare cavo omologato ai sensi di leggi e normative locali per sezione minima cavo vedere schema elettrico allegato para 9 3 Installare interruttore magnetotermico differenziale a monte...

Страница 5: ...omenu di interesse e Enter per confermare User Settings Menu DRYER SETTINGS DATE TIME BMS MOISTURE DRAIN OTHER LANGUAGE Utilizzare Up e Down per mo dificare il parametro e Enter per confermare la modi...

Страница 6: ...messa in servizio indossando i dovuti disposi tivi di protezione adeguati vedi tabella rischi residui para 1 4 PERICOLO DOVUTO A DEPRESSURIZZAZIONE IMPROVVI SA Non rimuovere componenti dell essiccator...

Страница 7: ...a USER SETTINGS MENU Selezionare BMS User Settings Menu DRYER SETTINGS DATE TIME BMS MOISTURE DRAIN OTHER LANGUAGE Compare la seguente schermata BMS U7 ADRESS 001 U8 BAUDRATE 9600 I parametri U7 e U8...

Страница 8: ...RG USER SETTINGS OTHER alla maschera U12 BACKLIGHT ON NO U13 Enable Money NO U14 Money Euro U15 Money KWh 0 120 U16 Saving Compared to Heatless U2 2 Parametro U12 Enable Money per abilitare la visuali...

Страница 9: ...o direttiva PED 2014 68 EU GWP Global Warming Potential 1774 In caso di fuga di refrigerante aerare il locale 6 3 Agente Essiccante L agente essiccante utilizzato non nocivo durante il rifornimento e...

Страница 10: ...er 3 depressurizzare l impianto utilizzando una valvola in uscita se presente o utilizzare lo scarico del filtro antipolvere 29 4 Assicurarsi che la pressione sia 0 bar verificando il manometro uscita...

Страница 11: ...NU X A 3 s AIN sonda sullo scarico compressore non funzionate S N Attivo A07 WARNING PROBE Thermal MassTemperature NU X A 3 s AIN sonda temperatura massa termica non funionante N N Attivo A08 WARNING...

Страница 12: ...alta pressione pressostato A N N Attivo A22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN bassa pressione pressostato B N N Attivo A23 WARNING ADSORBER High Pressure Column 2 X X X A 120s D...

Страница 13: ...A Errore sonda di pressione colonna 1 N N Attivo A37 WARNING PROBE PRESSU RE COLUMN 2 NU X X A Errore sonda di pressione colonna 2 N N Attivo A38 WARNING Pressure Dischar ge Failure Column 1 NU X X A...

Страница 14: ...ti compressore No Si Mancanza di refrigerante Si Pulire il condensatore Elevata perdita di carico Scambiatore intasato No Filtri intasati No Formazione ghiaccio No Si Pulire lo scambiatore e sosti tui...

Страница 15: ...guasto Si Sostituire P stato PV No ETV liquido chiusa Sostituire ETV Si Basso assorbimento corrente Si No Pressostato ventilatore starato No Mancanza refrigerante ricaricare Si Sostituire pres sostat...

Страница 16: ...Italiano 14 14 ATT060 090...

Страница 17: ...ed in accordance with the information and instructions given in the technical documentation supplied and always in such a way to avoid the creation of a hazardous situation The risks that it has not b...

Страница 18: ...void installations where the surrounding air contains solid and or gaseous pollutants e g sulphur ammonia chlorine and installations in marine environments The ducting of extracted air is not recommen...

Страница 19: ...s the time of the cycles of operation to obtain and maintain the predetermined dew point with the result of energy saving in case of work with partial loads Procedure to set dew point control Press Pr...

Страница 20: ...ct YES and confirm After few second the value return to NO FORCING SYSTEM OFF NO Y IMPORTANT Machine ON the machine should always work under pressure Machine OFF do not allow air to flow into the tank...

Страница 21: ...ass close Bypass open 5 3 2 USER PARAMETER Press the key Prg and enter on MAIN MENU Main Menu START STOP USER SETTINGS SERVICE INFORMATION Select USER SETTINGS press Enter to confirm Shows the user se...

Страница 22: ...est of a password INSERT PASSWORD 000 These configuration parameters must not be editable by the customer 5 3 4 INFORMATIONS On MAIN MENU select INFORMATION and press Enter to confirm Main Menu START...

Страница 23: ...checked to identify leaks at least once a year Circuits containing 30 kg or more of refrigerant fluid are checked to identify leaks at least once every six months EU No 517 2014 art 4 3 a 4 3 b d For...

Страница 24: ...of projection hazard of bodies against persons of things DANGER MACHINE UNDER TENSION Not perform maintenance while the machine is under tension or under pressure Do not remove any covers of the dryer...

Страница 25: ...A 3 s AIN Compressor Discharge Temperature Y N Active A07 WARNING PROBE Thermal MassTemperature Nu X A 3 s AIN Thermal Mass Temperature PROBE Not Connected Or Faulty N N Active A08 WARNING PROBE Capac...

Страница 26: ...22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN Air Pressure Switch B N N Active A23 WARNING ADSORBER High Pressure Column 2 X X X A 120s DIN Air Pressure Switch B N N Active A24 WARNING AD...

Страница 27: ...X A Error pressure PROBE column 1 N N Active A37 WARNING PROBE PRES SURE COLUMN 2 NU X X A Error pressure PROBE column 2 N N Active A38 WARNING Pressure Dis charge Failure Column 1 NU X X A If at the...

Страница 28: ...eteriorated No Yes low level refrigerant Yes Clean the condenser High pressure drop Exchanger dirty No Filters dirty No Formazione ghiaccio No Yes Clean the exchenger and substitute the pre filter Yes...

Страница 29: ...PV not set Yes Replace pressure switch Z ETV liquid closed Substitute ETV Z Yes Low current absorption Yes Fan pressure switch PV not set No refrigerant recharge Z Yes Replace pressure switch Z Excess...

Страница 30: ...English 14 14 ATT060 090...

Страница 31: ...tando la generaci n de situaciones peligrosas En la siguiente tabla se recogen los riesgos que no se hayan podido eli minar en la fase de dise o Pieza afec tada Riesgo residual Forma de exposi ci n Pr...

Страница 32: ...loro e instalaciones en entornos marinos La ventilaci n del aire extra do no es recomendada para las versiones con ventiladores axiales 3 5 Conexi n el ctrica Use un cable aprobado de acuerdo con la n...

Страница 33: ...ener y mantener el punto de roc o prede terminado ahorrando energ a en caso de trabajar con cargas parciales Procedimiento para fijar el control del punto de roc o Pulse Prg para entrar en el men prin...

Страница 34: ...ras unos segundos el valor vol ver a NO FORCING SYSTEM OFF NO YIMPORTANTE Estado m quina ON la m quina debe funcionar siempre a presi n Estado m quina OFF No deje entrar aire en los tanques que contie...

Страница 35: ...ss cerrado Bypass abierto 5 3 2PAR METRO DE USUARIO Pulse Prg para entrar en el MEN PRINCIPAL Main Menu START STOP USER SETTINGS SERVICE INFORMATION Seleccione USER SETTINGS pulse Enter para confirmar...

Страница 36: ...l cliente no tiene que poder editar estos par metros de configuraci n INFORMACIONES En MAIN MENU seleccione INFORMATION y pulse Enter confirmar Main Menu START STOP USER SETTINGS SERVICE INFORMATION E...

Страница 37: ...s que contengan 3 kg de fluido refrigerante o m s son comprobados para localizar fugas al menos una vez al a o Los circuitos que contengan 30 kg de fluido refrigerante o m s son com probados para loca...

Страница 38: ...osas o personas PELIGO APARATO BAJO TENSI N No realice labores de mantenimiento mientras e aparato est bajo ten si n o bajo presi n No quite ninguna tapa del secador ATENCI N TENSI N PELIGROSA ATENCI...

Страница 39: ...eTemperature Nu X A 3 s AIN Temperatura de descarga del compresor S N Activo A07 WARNING PROBE Thermal MassTemperature Nu X A 3 s AIN PROBE de la Temperatura de Masa t rmica No Conectado o Defectuoso...

Страница 40: ...Interruptor de Presi n del Aire A N N Activo A22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN Interruptor de Presi n del Aire B N N Activo A23 WARNING ADSORBER High Pressure Column 2 X X X...

Страница 41: ...ivo A37 WARNING PROBE PRES SURE COLUMN 2 NU X X A Error PROBE de presi n columna 2 N N Activo A38 WARNING Pressure Dis charge Failure Column 1 NU X X A Si al final de la fase de drenaje la presi n es...

Страница 42: ...com presor deteriorados No S Nivel bajo refrigerante S Limpie el conden sador Ca da de la alta presi n Intercambiador sucio No Filtros sucios No Formaci n de hielo No S Limpie el inter cambiador y ca...

Страница 43: ...presi n Z ETV l quido cerrado Substituto ETVZ S Baja absorci n de la corriente S Interruptor de pre si n del ventilador PV sin configurar Sin recarga de refri gerante Z S Cambie el interruptor de la...

Страница 44: ...Espa ol 14 14 ATT060 090...

Страница 45: ...ie Anweisungen in den technischen Ger teunterlagen strikt einzuhalten in jedem Fall ist jedes Vorgehen zu vermeiden dass zu einer Gefahrensituation f hrt Die Restrisiken die beim Bau der Ma schine nic...

Страница 46: ...ors sollte von einer Installation in Bereichenabgesehenwerden indenendieLuftfesteund odergasf rmige kontaminierende Stoffe enth lt z B Schwefel Ammoniak Chlor das gilt auch f r Installationen in Meere...

Страница 47: ...itszyklen um den gew nschten Tau punkt zu erreichen oder aufrecht zu erhalten dadurch wird bei Teillast betrieb Energie gespart Zur Einstellung dieser Betriebsart wie folgt vorgehen Mit Prg das Hauptm...

Страница 48: ...CTLY YES JA anw hlen und best ti gen Nach einigen Sekunden kehrt der Wert auf NO Nein zur ck FORCING SYSTEM OFF NO YACHTUNG Maschinenstatus ON Die Maschine muss immer unter Druck arbeiten Maschinensta...

Страница 49: ...einstellungen anw hlen und mit Enter best tigen Das Untermen mit den dem Benutzer zug nglichen Parametern wird einge blendet User Settings Menu DRYER SETTINGS DATE TIME BMS MOISTURE DRAIN OTHER LANGUA...

Страница 50: ...MAIN MENU die Option INFORMATION w hlen und mit Enter best tigen Main Menu START STOP USER SETTINGS SERVICE INFORMATION Aus dieser Seite k nnen die Systeminformationen und die Fehlerent wicklungsdate...

Страница 51: ...Die Kreisl ufe die 3 kg oder mehr K ltemittel enthalten sind mindestens einmal j hrlich auf K ltemittelverluste zu kontrollieren Die Kreisl ufe die 30 kg oder mehr K ltemittel enthalten sind mindesten...

Страница 52: ...s Element w hrend der Druckbeaufschlagung der Anlage ausgesto en werden mit der Folge Verletzungs oder Besch digungsgefahr durch herausge schleuderte Gegenst nde GEFAHR MASCHINE UNTER SPANNUNG Nie War...

Страница 53: ...r DischargeTempera ture Nu X A 3 s AIN F hler am Kompressorauslass defekt J N Aktiv A07 WARNING PROBE Thermal MassTemperature Nu X A 3 s AIN Temperaturf hler thermische Masse defekt N N Aktiv A08 WARN...

Страница 54: ...DIN Hochdruck Druckschalter A N N Aktiv A22 WARNING ADSORBER Low Pressure Column 2 X X X A 120s DIN Niederdruck Druckschalter B N N Aktiv A23 WARNING ADSORBER High Pressure Column 2 X X X A 120s DIN H...

Страница 55: ...6 WARNING PROBE PRES SURE COLUMN 1 NU X X A Fehler Druckf hler S ule 1 N N Aktiv A37 WARNING PROBE PRES SURE COLUMN 2 NU X X A Fehler Druckf hler S ule 2 N N Aktiv A38 WARNING Pressure Di scharge Fail...

Страница 56: ...ch digt Nein Ja K ltemittel unzureichend Ja Den Kondensator reinigen Hohe Druckverluste W rmetauscher verstopft Nein Filter verstopft Nein Eisbildung Nein Ja W rmetauscher reinigen und Vorfilter erset...

Страница 57: ...Fl ssigkeit ge schlossen ETV ersetzen Z Ja Niedriger Stromaufnahme Ja Ventilator dreht nicht Druckw chter PV defekt Fehlen von K ltemittel Nachf llenZ Ja Druckw chter ersetzen Z W rmelast zu hoch Nie...

Страница 58: ...Deutsch 14 14 ATT060 090...