7 - Anchoring on flat ground with base box
Strada Evolution 2 - Transfer and Rapide - Installation manual
22 / 42
7.
Anchoring on flat ground with base box
7.1
Recommendation
For anchoring on flat ground, Parkeon recommends the following:
•
concrete base (B25),
•
minimum concrete thickness 500 mm (minimum drilling depth 250 mm),
•
the use of chemical anchors of the Spit C Mix Plus make.
IMPORTANT:
The chemical anchoring kit is not supplied with the kit for fastening on
flat ground with base box.
7.2
Composition of fasteners
The parts required are:
Quantity
Description
Illustration
1
Base box
16
(or 12 nuts
with 4 couplings)
M16 nut
Coupling
4
Washer
4
M16 threaded rod
(450 mm)
1
Anchoring protection
plate
IMPORTANT:
The removal protection nut is not supplied with the kit for fastening on
flat ground with base box, but with the machine.