background image

H. SPECIFICATIONS

PARI TREK

® 

S PORTABLE AEROSOL SYSTEM SPECIFICATIONS

Weight: (Compressor only) ...................................................................................................................................................................0.8 lb
With Rechargeable Battery: ................................................................................................................................................................. 1.2 lbs
Dimensions: (Compressor only) ...................................................................................................................................4.5” x 3.5” x 1.75”
Certification:  .............................................................................................................................IEC/EN 60601-1 and IEC/EN 60601-1-2

COMPRESSOR PERFORMANCE:

Maximum Pressure of Compressor: ................................................................................................................................. 35 PSI (2.4 Bar)
Maximum Liter Flow of Compressor: ............................................................................................................................................8.5 LPM
Operating Pressure of Compressor¹: ............................................................................................................................14.5 PSI (1.0 Bar)
Operating Liter Flow of Compressor¹: ..........................................................................................................................................4.0 LPM

¹Measured with PARI LC

®

 Sprint or LC

®

 Plus Reusable Nebulizer attached.

AMBIENT OPERATION:

Temperature Range: ................................................................................................................................................................. 50ºF to 104ºF 

TRANSPORT/STORAGE:

Ambient Temperature: ............................................................................................................................................................. 13ºF to 158ºF
Humidity: ........................................................................................................................................................................................ 10% to 95%
Atmospheric Pressure: .................................................................................................................................................. 500 hPa - 1060 hPa
Compressor Electrical Requirements: ....................................................................................................Input 12 VDC 1.67 A 18 watts

OPTIONAL RECHARGEABLE BATTERY:

Battery Type: .................................................................................................................................................................... Lithium Ion (Li-lon)
Operating time with battery: .......................................................................................................................... Approximately 40 minutes
Number of treatments per charge

2

 ...........................................................................................................Approximately 8 treatments

Normal time to charge: ......................................................................................................................................... Approximately 2 hours

2

Using a PARI Reusable Nebulizer to nebulize 2.5 ml of medication.

ELECTRICAL REQUIREMENTS:

Input: ......................................................................................................................................................................................... 12 VDC  1.67 A
Output: ..................................................................................................................................................................................... 12 VDC  1.67 A

MULTI-VOLTAGE AC ADAPTER:

FUHUA Model # UE24WU-120167SPA or equivalent
Input Voltage: ............................................................................................................................................... 100-240 VAC 50/60Hz 600mA
Output Voltage: ........................................................................................................................................................................12V DC 1.67A

EXPLANATION OF SYMBOLS

Attention : Read all ‘Instructions for Use’ before operation: ......................................................................................................

Insulation enclosed Class II equipment: ...........................................................................................................................................

Type “B” Protection from electrical shock: .....................................................................................................................................

Do not dispose of in unsorted municipal trash.  

Please consult local laws and regulations for proper disposal: ...................................................................................................

Power Switch: .........................................................................................................................................................................................

‘ON’ Position (compressor running): ...............................................................................................................................................

‘OFF’ Position (compressor is not running): ...................................................................................................................................

NOTE:

 When switch is in the ‘off ’ position and the compressor is not running, there will still be electrical potential inside the 

compressor housing. To remove power from the compressor, the power plug or battery must be removed. 

Questions? 1.800.FAST.NEB (327.8632)  |  PARI.com/TrekS

EN-9

Содержание Trek S

Страница 1: ...RUCTIONS BEFORE USE USE THE PRODUCT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THESE INSTRUCTIONS FOR USE IMPROPER USE CAN RESULT IN SERIOUS OR FATAL ILLNESS INJURY IMPROPER TREATMENT OR PROPERTY DAMAG...

Страница 2: ...d physically or mentally impaired Never use when sleeping or drowsy 5 This product contains small parts that may present a choking hazard to small children The tubing also presents a strangulation haz...

Страница 3: ...luids enter the unit return the product to PARI for examination and repair 10 Do not cover up or use the PARI Trek S compressor inside the carry case Covering the device may cause excessive heat build...

Страница 4: ...2 PARI com TrekS EN 3 Nebulizer Holder Power Switch Power Receptacle Air Outlet Wing Tip Tubing Wing Tip Tubing PARI LC Sprint Reusable Nebulizer 2 included InspiratoryValve Cap Nebulizer Outlet Mouth...

Страница 5: ...er or 12V DC adapter are plugged into the power receptacle Fig D 3 Attach the rechargeable battery to the PARI Trek S by placing the battery onto the rear section of the compressor and sliding it into...

Страница 6: ...ARADOR B B E NOTE Do not leave the multi voltage AC Adapter plugged into the rechargeable battery for more than 7 days Leaving the battery connected to the power adapter for long periods of time may d...

Страница 7: ...nebulizer Fig H 7 StartingTreatment Sit in a relaxed upright position and turn the compressor ON 8 Nebulizer Position Place the mouthpiece on top of tongue and close lips around it Take slow deep brea...

Страница 8: ...ee cloth Reassemble nebulizer when parts are dry and store 7 You can also wash all parts of the reusable nebulizer on the top shelf of a dishwasher DO NOT WASH TUBING Place the reusable nebulizer part...

Страница 9: ...A good rule to follow is to replace your filter every 6 months at the same time as your PARI reusable nebulizer Questions 1 800 FAST NEB 327 8632 PARI com TrekS EN 8 Removing First make sure the Trek...

Страница 10: ...imately 40 minutes Number of treatments per charge2 Approximately 8 treatments Normal time to charge Approximately 2 hours 2 Using a PARI Reusable Nebulizer to nebulize 2 5 ml of medication ELECTRICAL...

Страница 11: ...tient Connection at 1 800 FAST NEB 327 8632 Press 2 THERE ARE NO OTHER EXPRESS WARRANTIES ALL IMPLIED WARRANTIES ON THE PARI TREK S COMPRESSOR AND ITS PARTS INCLUDING IMPLIED WARRANTIES OF MERCHANTABI...

Страница 12: ...ECUADO O DA O A LA PROPIEDAD INSTRUCCIONES DE USO El nebulizador es para uso individual solamente ESTAS INSTRUCCIONES SE APLICAN A LA NEBULIZADOR PARI LC SPRINT IMPORTANTE LEA LAS INSTRUCCIONESY PRECA...

Страница 13: ...ica o mental cerca Nunca lo use mientras duerme o est somnoliento 5 El producto contiene piezas peque as que pueden presentar un riesgo de asfixia para ni os peque os La entubaci n adem s presenta un...

Страница 14: ...sor El l quido puede causar da os en las piezas el ctricas y del compresor y un funcionamiento incorrecto En caso de que entre l quido a la unidad devuelva el producto a PARI para que lo revisen y rep...

Страница 15: ...rico Enchufe el ctrico Salida de aire Entubaci n Wing Tip Entubaci n Wing Tip Nebulizadores reutilizables PARI LC Sprint ctd se incluyen dos Tapa de la v lvula de inspiraci n Salida del nebulizador Bo...

Страница 16: ...lo Compresor S lo Bater a con Compresor 2 La bater a recargable no se puede conectar directamente al PARI Trek S si el adaptador CA o el adaptador de 12VCC est n conectados al enchufe el ctrico Fig D...

Страница 17: ...B B E NOTA No deje enchufado el adaptador CA de voltaje m ltiple a la bater a recargable por m s de 7 d as Si deja la bater a conectada al adaptador el ctrico por per odos prolongados puede reducir l...

Страница 18: ...n Wing Tip a la parte inferior del nebulizador reutilizable PARI Fig H 7 Inicie el tratamiento Si ntese en una posici n relajada y recta y coloque el compresor en ON 8 Posicione el nebulizador Coloque...

Страница 19: ...la lavadora de platos Extraiga y seque las piezas despu s de que finalice el ciclo de la lavadora de platos NOTA SOBRE ELTIEMPO DETRATAMIENTO Tenga en cuenta que son muchos lo factores que afectan el...

Страница 20: ...mplazar inmediatamente el filtro si se moja o se obstruye Una buena norma es reemplazar el filtro cada 6 meses al mismo tiempo que su nebulizador reutilizable PARI Extracci n En primer lugar aseg rese...

Страница 21: ...roximadamente 40 minutos N mero de tratamientos por carga2 Aproximadamente 8 tratamientos Tiempo normal de carga Aproximadamente 2 horas 2 Usando un nebulizador reutilizable PARI para nebulizar 2 5 ml...

Страница 22: ...STEN OTRAS GARANT AS EXPRESAS TODAS LAS GARANT AS IMPL CITAS DEL COMPRESOR PARITREK SY SUS PIEZAS INCLUIDAS LAS GARANT AS IMPL CITAS DE COMERCIABILIDADYADECUACI N PARA UN PROP SITO PARTICULAR SE LIMIT...

Отзывы: