SafeAir™ M-600 Installation Guide
19
www.parazero.com
SafeAir M-600 V2 model
7
System Activation
SafeAir M-600 V2 model
7.1
System LED indications
Color
Description
Possible actions
Yellow
Solid light - System initialization
Normal indication, no action
required
Light blinks once
Check RC channels are in their
safe position
Check RC connector is inserted
properly
Light blinks twice
Make sure that the drone is level
Light blinks 3 times
SD card problem, contact
support
Red
System not armed: Parachute
connection test failed
Make sure that the safety pin is
removed before take off
Verify that the parachute
connector is connected
correctly. See SmartAir’s back
side socket c on SmartAir
Connectors Overview chapter
Otherwise contact Parazero for
further instructions
Power down the system
After arming: System deployed
Power down the system
Blue
System is in idle state
Buzzer – short beep
Arm the system
Power down the system
Green
System is armed.
Buzzer – long beep
Do not approach or power down
the system when it’s in this state!
Disarm the system
Trigger the system
Purple
System is disarmed
Buzzer – double-beep
Return to idle
Power down the system
Cyan
Light blinks
Internal test
Normal indication, no action
required
Orange
Light blinks
Internal test
Normal indication, no action
required