Parasound HCA-806A Specifications

Continuous Power Output

> 80 watts RMS x 6,  20 Hz - 20 kHz,  8 

Ω 

, all channels driven

> 120 watts RMS x 6,  20 Hz - 20 kHz,  4 

Ω 

, all channels driven

Continuous Power Output - Bridged

> 180 watts RMS,   20 Hz - 20 kHz,  8 , each bridged channel, 3+4, 5+6

Current Capacity

30 amperes peak, per channel

Slew Rate

> 130 V/µsecond

Frequency Response

20 Hz - 120 kHz, +0/-3 dB

Total Harmonic Distortion

<  0.05% at full power
<  0.02% typical levels

IM Distortion

<  0.03%

TIM

Unmeasureable

Dynamic Headroom

> 2 dB

Interchannel Crosstalk

> 76 dB at 1 kHz
> 55 dB at 20 kHz

Input Impedances

50 k

Ω 

 per channel, without looping inputs 1/2 to Ch. 3/4 or Ch. 5/6

25 k

Ω 

 per channel, if looping inputs 1/2 to either Ch. 3/4 or Ch. 5/6

17 k

Ω 

 per channel, if looping inputs 1/2 to both Ch. 3/4 and Ch. 5/6

Input Sensitivity

1.0 V

S/N Ratio

> 110 dB, input shorted, IHF A-weighted

Damping Factor

> 800 at 20 Hz

Dimensions

19" wide x 5 1/4" high x 19" deep (6 1/8" high with feet)

Weight

50 lbs. net

Содержание HCA 806A

Страница 1: ...g h C u r r e n t M u l t i A m p l i f i e r H C A 8 0 6 A H i g h C u r r e n t M u l t i A m p l i f i e r Current Overload 1 2 3 4 5 6 AC Line Standby Normal O W N E R S M A N U A L HCA 806A Six Channel High Current Power Amplifier ...

Страница 2: ...rements for Your Amplifier 5 Input Connections and Switch Settings for the HCA 806A 6 Multi Zone Stereo Operation 7 Speaker Connections 7 Mono Bridging 8 AC Power Connections and AC Grounding 8 DC Trigger Connection 8 Operating Your HCA 806A 9 Maintaining Your Parasound Amplifier 9 Fuse 9 In Case of Trouble 10 Special Features 10 Specifications 11 Parasound Limited Warranty USA only 13 ...

Страница 3: ...g This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them 12 Lightning Unplug the un...

Страница 4: ...Mono Bridging Independant Loop 1 2 3 4 On CH 3 Ch 4 Mono Bridging Independant Non Bridgeable Mono Bridging 8 Ω Min Mono Bridging 8 Ω Min Levels Off Loop 1 2 3 4 On Off CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 Main Fuse AC Cord Connector Carry Handle Bridge Switches Input Looping Level Controls Input Connectors DC Trigger GND 12 V 12 Vdc Trigger Connector Power Power Switch Status Indicators EIA Rack Mount Ho...

Страница 5: ...nt rack Be sure to use heavy duty mounting bolts to and nylon shoulder washers on both sides of the faceplate to avoid scratching the amplifier s front panel and to help prevent ground loops Contact Middle Atlantic Products at 201 839 1011 to obtain any rack mounting hardware you may need When rack mounting equipment have someone help support the unit while you bolt the component to the rack rails...

Страница 6: ...gurations depending upon your needs Below are examples of four and five channel operation Input Connections for Four Channel Operation Use INPUTS 1 and 2 for your front left and right channels Use INPUTS 3 and 4 bridged mono for your center channel Connect the center output of your processor to INPUT 4 only Use INPUTS 5 and 6 bridged mono for your subwoofer Connect the subwoofer output of your pro...

Страница 7: ... the speaker wire will have some sort of mark either printing a raised ridge on the insulation or a different color of conductor This permits you to know which wire you had connected to the and which to the speaker terminals so you can do exactly the same at the power amplifier terminals Polarity is marked separately for both stereo and bridged connections Banana Plugs Banana plugs offer the most ...

Страница 8: ...nimum 8 Ω nominal impedance for each speaker connected to bridged channels 3 4 or 5 6 Use of lower impedance at high listening levels may cause overheating or trigger one of the amplifier s protection circuits These restrictions result from the mathematics of the bridging circuitry In the bridge mode each channel of the amplifier functions for only the or half of the musical waveform Thus each cha...

Страница 9: ... continues to glow contact your Dealer Installer or Parasound Technical Service for further advice Current Overload LEDs The current overload LEDs for channels 1 through 6 will only illuminate if the unit is driven continuously at or past its maximum current capacity These LEDs will indicate overload of the power supply just before the onset of audible distortion In virtually all imaginable listen...

Страница 10: ...out a suitable shipping carton or evidence of improper internal packing will be refused We cannot accept collect shipments After repair under warranty the unit will be returned to you prepaid If we found no problem with the unit we will return the unit with collect charges for return shipping charges Special Features l Massive 1 2 kVA Power Transformer l 90 000 uF Computer grade Capacitors in the ...

Страница 11: ...Total Harmonic Distortion 0 05 at full power 0 02 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 2 dB Interchannel Crosstalk 76 dB at 1 kHz 55 dB at 20 kHz Input Impedances 50 kΩ per channel without looping inputs 1 2 to Ch 3 4 or Ch 5 6 25 kΩ per channel if looping inputs 1 2 to either Ch 3 4 or Ch 5 6 17 kΩ per channel if looping inputs 1 2 to both Ch 3 4 and Ch 5 6 Input S...

Страница 12: ...warranty This warranty becomes void if the product has been damaged by alteration misuse accident or neglect Alteration includes any removal obscuration or defacement of its serial number This warranty becomes void if unit has been connected or operated contrary to printed instructions The warrantor assumes no liability for property damage or any other incidental or consequential damage whatsoever...

Отзывы: