Introduction

Congratulations on your purchase of this precision audio component and thank you for your selection of
Parasound. Please take a few moments to read these instructions so that you may fully understand the
capabilities of your new Parasound power amplifier.

Unpacking Your Amplifier

Carefully unpack your amplifier and remove all the enclosed accessories. Be sure to inspect the unit for
any possible shipping damage. If you see any, contact your Parasound Dealer immediately. Save all the
packing material in case you need to ship the amplifier for repair. Before you proceed, find the serial
number located on the rear panel of your amplifier and record it here for reference:

Serial #____________________

Date of Purchase____________________

Installing and Rack Mounting Your Amplifier

Place your amplifier away from heat sources such as air ducts and radiators. Always mount the amplifier
horizontally and make sure that your cabinet or shelf can support its weight. It is best to provide a
separate shelf for your amplifier rather that stacking it directly above or below your other components.

Both the HCA-806A occupies three rack spaces (5 1/4") in a standard 19 inch equipment rack. Be sure
to use heavy duty mounting bolts to and nylon shoulder washers on both sides of the faceplate to avoid
scratching the amplifier’s front panel and to help prevent ground loops.

Contact Middle Atlantic Products at (201) 839-1011 to obtain any rack mounting hardware you may
need. When rack mounting equipment, have someone help support the unit while you bolt the
component to the rack rails.

Ventilation Requirements for Your Amplifier

To insure safe and reliable operation, it is very important that the amplifier has plenty of ventilation to
prevent overheating and automatic shut down from its thermal protection circuitry. Please observe the
following ventilation guidelines when installing your amplifier in a cabinet or other enclosed area:

1)  If you are not using a fan, allow at least six inches on each side and above the amplifier, and do not
close off the front with a cabinet door or panel.
2)  If you are enclosing the amplifier within an equipment cabinet, use a fan to draw in cool air and
exhaust warm air. Two vent holes are required: one for intake and one for exhaust.
3)  Do not place the amplifier on carpeting that will obstruct the air flow into the bottom of the amplifier
chassis and heatsinks.
4)  Avoid stacking components. If you do stack components, you must use a fan to circulate the warm air
that will quickly become trapped between them when they are powered on.

Содержание HCA 806A

Страница 1: ...g h C u r r e n t M u l t i A m p l i f i e r H C A 8 0 6 A H i g h C u r r e n t M u l t i A m p l i f i e r Current Overload 1 2 3 4 5 6 AC Line Standby Normal O W N E R S M A N U A L HCA 806A Six Channel High Current Power Amplifier ...

Страница 2: ...rements for Your Amplifier 5 Input Connections and Switch Settings for the HCA 806A 6 Multi Zone Stereo Operation 7 Speaker Connections 7 Mono Bridging 8 AC Power Connections and AC Grounding 8 DC Trigger Connection 8 Operating Your HCA 806A 9 Maintaining Your Parasound Amplifier 9 Fuse 9 In Case of Trouble 10 Special Features 10 Specifications 11 Parasound Limited Warranty USA only 13 ...

Страница 3: ...g This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them 12 Lightning Unplug the un...

Страница 4: ...Mono Bridging Independant Loop 1 2 3 4 On CH 3 Ch 4 Mono Bridging Independant Non Bridgeable Mono Bridging 8 Ω Min Mono Bridging 8 Ω Min Levels Off Loop 1 2 3 4 On Off CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 Main Fuse AC Cord Connector Carry Handle Bridge Switches Input Looping Level Controls Input Connectors DC Trigger GND 12 V 12 Vdc Trigger Connector Power Power Switch Status Indicators EIA Rack Mount Ho...

Страница 5: ...nt rack Be sure to use heavy duty mounting bolts to and nylon shoulder washers on both sides of the faceplate to avoid scratching the amplifier s front panel and to help prevent ground loops Contact Middle Atlantic Products at 201 839 1011 to obtain any rack mounting hardware you may need When rack mounting equipment have someone help support the unit while you bolt the component to the rack rails...

Страница 6: ...gurations depending upon your needs Below are examples of four and five channel operation Input Connections for Four Channel Operation Use INPUTS 1 and 2 for your front left and right channels Use INPUTS 3 and 4 bridged mono for your center channel Connect the center output of your processor to INPUT 4 only Use INPUTS 5 and 6 bridged mono for your subwoofer Connect the subwoofer output of your pro...

Страница 7: ... the speaker wire will have some sort of mark either printing a raised ridge on the insulation or a different color of conductor This permits you to know which wire you had connected to the and which to the speaker terminals so you can do exactly the same at the power amplifier terminals Polarity is marked separately for both stereo and bridged connections Banana Plugs Banana plugs offer the most ...

Страница 8: ...nimum 8 Ω nominal impedance for each speaker connected to bridged channels 3 4 or 5 6 Use of lower impedance at high listening levels may cause overheating or trigger one of the amplifier s protection circuits These restrictions result from the mathematics of the bridging circuitry In the bridge mode each channel of the amplifier functions for only the or half of the musical waveform Thus each cha...

Страница 9: ... continues to glow contact your Dealer Installer or Parasound Technical Service for further advice Current Overload LEDs The current overload LEDs for channels 1 through 6 will only illuminate if the unit is driven continuously at or past its maximum current capacity These LEDs will indicate overload of the power supply just before the onset of audible distortion In virtually all imaginable listen...

Страница 10: ...out a suitable shipping carton or evidence of improper internal packing will be refused We cannot accept collect shipments After repair under warranty the unit will be returned to you prepaid If we found no problem with the unit we will return the unit with collect charges for return shipping charges Special Features l Massive 1 2 kVA Power Transformer l 90 000 uF Computer grade Capacitors in the ...

Страница 11: ...Total Harmonic Distortion 0 05 at full power 0 02 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 2 dB Interchannel Crosstalk 76 dB at 1 kHz 55 dB at 20 kHz Input Impedances 50 kΩ per channel without looping inputs 1 2 to Ch 3 4 or Ch 5 6 25 kΩ per channel if looping inputs 1 2 to either Ch 3 4 or Ch 5 6 17 kΩ per channel if looping inputs 1 2 to both Ch 3 4 and Ch 5 6 Input S...

Страница 12: ...warranty This warranty becomes void if the product has been damaged by alteration misuse accident or neglect Alteration includes any removal obscuration or defacement of its serial number This warranty becomes void if unit has been connected or operated contrary to printed instructions The warrantor assumes no liability for property damage or any other incidental or consequential damage whatsoever...