21
TROUBLE SHOOTING
PRESSURE INCREASE AT FILTER:
• Clean the filter
• Clean all baskets - skimmer, debris canister, pump
• Check all ancillary valves are adjusted correctly
NOZZLE POPS UP BUT DOES NOT ROTATE:
• Push the nozzle up and down (with water pressure directed to that nozzle) to dislodge any debris
• If necessary remove the nozzle, dismantle and clean it. Clear the pipe by running the system on Pause
on that line before reinstalling the nozzle
VALVE CYCLES BUT NOZZLES REMAIN UP:
• You can determine whether the module is at fault by removing and rinsing it then replacing it in a new
position. If the problem shifts to a different nozzle, then it is probably the module. If the problem stays at
the same nozzle then the problem is probably at the nozzle.
• Check for debris in the nozzle
• Check for (and clean out) glue or debris in the Water Valve base - particularly on the ribs or in the locating
holes
• Check for debris lodged anywhere in the module
• If necessary replace module (defective modules must be returned to Distributor for Warranty Credit)
WATER VALVE DOES NOT CYCLE:
• Check Run/Pause switch is on Run
• Remove and clean module to ensure it is free of debris. Check that the Turbine shaft can spin freely and that
the gears are meshing properly. If necessary, replace module.
NOZZLE WILL NOT POP UP:
• Check for clogged pipe or for debris in nozzle
• Check Water Valve is rotating
Содержание VANTAGE IN-FLOOR CLEANING SYSTEM
Страница 28: ......