5. Carefully remove new lamp assembly from box. Insert
lamp(s) into lamp holder. lamp(s) must be aligned
and seated securely in the lamp holder. Roll the black
o-ring(s) up onto the ceramic end of lamp from position
A to B, Fig. 8. Gently insert lamps into the lower lamp
retainer Fig. 9 and lower lamp assembly into unit.
6. Re-install the spring clip and re-attach the lamp
connector(s) to the ballast. Note: The lamp
connector(s) can only be installed one way.
7. Discard lamp(s) appropriately. Visit www.
lamprecycle.org for instructions on disposal.
Complete steps 1-4. Remove lamp(s) Fig. 5 and
discard aluminum disc and yellow centering discs
Fig. 6. Dispose lamp(s) accordingly. Continue on to
step 5.
(Older Ultra UV with yellow centering discs)
(Older Ultra UV, discard aluminum disc)
Remove aluminum
disc from quartz tube
Fig. 5
Fig. 6
To remove the aluminum disc in older Ultra UV units do
one of the following.
1. Refer to the quartz tube cleaning instructions in your
manual, also available at www.1paramount.com and
remove the disc in the cleaning process.
2. Using a rod long enough to reach the bottom of
the quartz tube use a sticky substance (duct tape,
silicone, shop vac etc) at one end of the rod to stick
to the aluminum disc and lift the disc out of the
quartz tube.
RETROFITTING OLDER
ULTRA UV UNITS WITH NEW
LAMP ASSEMBLY
NOTICE
Fig. 8
Fig. 9
B
A
Fig. 7