1. Turn off all power to the ULTRA UV2 unit and all
other pool equipment. Unplug the unit from its power
receptacle or turn OFF the circuit breaker that is the
ULTRA UV2’s power source. Before proceeding to
step 2 allow at least 15 minutes for the lamp(s) in the
unit to cool.
Never remove the
electrical enclosure
cover without first
disconnecting the power (power source) for the Ultra
UV2 unit. Never remove the Ultra UV2 unit’s cover
without turning off the pump.
DANGER
2. Remove the three screws that secure the plastic cover
then remove Fig. 1.
Before removing
lamps you must wear
protective rubber
gloves and safety eye wear. Do not handle a hot lamp
or serious burns will occur.
WARNING
Do not touch the
glass part of the
lamp as body oils will
create hot spots & greatly shorten lamp life.
NOTICE
3. Disconnect all lamps by pressing the release tabs on
connectors and gently pulling apart. Fig. 2
4. Remove the spring clip Fig. 3. Carefully lift the old lamp
assembly, including lamp holder, from the quartz tube
Fig. 4. Do not pull excessively on the lamp wires.
Fig. 2
Fig. 3
Fig. 4
Fig. 1
LAMP ASSEMBLY REPLACEMENT