background image

1.  Turn off all power to the ULTRA UV2 unit and all 

other pool equipment. Unplug the unit from its power 
receptacle or turn OFF the circuit breaker that is the 
ULTRA UV2’s power source. Before proceeding to 
step 2 allow at least 15 minutes for the lamp(s) in the 
unit to cool.

Never remove the 
electrical enclosure 
cover without first 

disconnecting the power (power source) for the Ultra 
UV2 unit. Never remove the Ultra UV2 unit’s cover 
without turning off the pump.

 

DANGER

2.  Remove the three screws that secure the plastic cover 

then remove Fig. 1. 

Before removing 
lamps you must wear 
protective rubber 

gloves and safety eye wear. Do not handle a hot lamp 
or serious burns will occur. 

 

WARNING

Do not touch the 
glass part of the 
lamp as body oils will 

create hot spots & greatly shorten lamp life.

NOTICE

3.  Disconnect all lamps by pressing the release tabs on 

connectors and gently pulling apart. Fig. 2

4.  Remove the spring clip Fig. 3. Carefully lift the old lamp 

assembly, including lamp holder, from the quartz tube 
Fig. 4. Do not pull excessively on the lamp wires. 

Fig. 2

Fig. 3

Fig. 4

Fig. 1

LAMP ASSEMBLY REPLACEMENT

Отзывы: