background image

295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
[email protected] • www.1Paramount.com

004-027-9000-00    REV 01    Publish 07/17/18 

ECN_1584

INSTALLATION & 

OPERATIONS MANUAL

When using this electrical equipment, basic safety precautions 
should always be followed, including the following:
• Follow all applicable electrical codes. 

•  Turn off power at main source before making any electrical connections or servicing the unit.
•  To reduce the risk of electric shock, injury or death disconnect unit from power supply
• Follow the instructions or risk of serious injury or death could occur!
•  To reduce risk of injury, do not permit children to use this product unless they are closely 

supervised at all times.

•  Risk of electric shock. Install at least 5 feet (1.5m) from inside wall of pool, hot tub or spa using 

nonmetallic plumbing.

•  This product shall only be connected to a power supply receptacle protected by a ground fault 

circuit interrupter.

UV EXPOSURE & PROTECTION:

UV-A and UV-B radiation can have adverse short and long term effects on the eyes and skin. Never 
look directly at a UV lamp that is connected to a power source. Avoid UV skin exposure at all times.

 

WARNING

Pool, Spa & Pond 
Water Sanitizer 4BJ1

EPA Registered
#084221-AZ-001

RISK OF INJURY

A) Replace damaged cord immediately.
B) Do not bury cord

C) Connect to a grounded, grounding type receptacle only.

 

DANGER

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Содержание Ultra UV2

Страница 1: ...e risk of injury do not permit children to use this product unless they are closely supervised at all times Risk of electric shock Install at least 5 feet 1 5m from inside wall of pool hot tub or spa...

Страница 2: ...pplications other than those indicated above will void your warranty and could be harmful to your health or the health of others WARNING DANGER CAUTION WARNING NOTICE Indicates a hazardous situation w...

Страница 3: ...desired rate of sanitation Please note that the minimum posted flow rate must be met or exceeded to ensure proper system performance The water flow rate through the UV unit is governed by the piping...

Страница 4: ...rates of 3 lamp units which come with 4 unions and 4 plugs NOTE The use of multiple inlets outlets will require additional unions Use the plugs provided with the Ultra UV2 in the unused inlets and out...

Страница 5: ...uld be glued into the union tail pieces using an appropriate primer and ABS to PVC cement Inlet piping should be supported and should not rest solely upon the unions to avoid stressing or breaking the...

Страница 6: ...provides a path of least resistance for electrical current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The p...

Страница 7: ...nit subject to your local electrical codes Do not cut the plug off the electrical cord and connect it directly to a 120V power source If this is done your warranty is voided and the U L listing is inv...

Страница 8: ...or more then refer to the troubleshooting section of this manual on page 13 The filter gauge DOES NOT indicate the pressure in the UV unit NOTICE Do not look directly at the lamps Serious injury will...

Страница 9: ...e warranty Option 1 Removing the unit for the winter Turn off the power to the unit Disconnect the unions on the plumbing to ensure that the unit is completely drained Now with the power off disconnec...

Страница 10: ...rns will occur WARNING Do not touch the glass part of the lamp as body oils will create hot spots greatly shorten lamp life NOTICE 3 Disconnect all lamps by pressing the release tabs on connectors and...

Страница 11: ...reinstall the quartz tube place a new O ring 2 inches from the top of the outside of the quartz tube Fig 14 Gently lower the quartz tube into the unit until the O ring makes contact with the top of t...

Страница 12: ...tive rubber gloves and safety eye wear Do not handle a hot lamp or serious burns will occur WARNING Do not touch the glass part of the lamp as body oils will create hot spots greatly shorten lamp life...

Страница 13: ...e Ultra UV2 unit is operating at minimum of 2psi which is required to activate the pressure switch Please note that the filter gauge does not indicate the pressure in the UV unit c If the operating pr...

Страница 14: ...t on the same electrical circuit from any fault to ground the same as the electrical breaker protects the total electrical circuit from a short When the GFCI trips it is an indication that there is an...

Страница 15: ...tube seal or b a broken or cracked quartz tube Check the quartz tube seal and quartz tube as instructed in page 4 SPECIFICATION NOTICE Due to Paramount s commitment to continual product improvement al...

Страница 16: ...5 422 2009 06 2 Union Kits 9 005 422 2009 07 63mm Union Kits 10 005 422 3000 00 Replacement Housing 11 005 422 2009 08 2 Blanking Plug 12 005 422 2009 09 Quartz Tube With Seal Kit 13 005 422 2009 04 S...