Fig. 4

Bonding Lug

WIRING INSTRUCTIONS ON THE ULTRA UV2
The Ultra UV2 must be wired to a GFI. The ballast is voltage sensing. 
The terminal block inside the unit will either be wired with 2 hot leads 
or one hot and one neutral lead. The green will always be wired to the 
grounding post (Step 1).
1.  Run the 3 wires through the flex-tite conduit and the flex-tite female 

nut. Run the 3 wires through the remaining part of the flex-tied 
connector and into the unit (Step 2).

2.  Make sure there is extra wire inside the unit to easily reach the 

connector bar and grounding post in the unit.

3.  Then apply silicon to the wires to the inside of the connector to 

form a plug (Step 2) before pushing or screwing the flex-tite to the 
barbed/threaded end of the connector that is filled with silicone. 
Then attach the flex-tite female connector nut to the male part of the 
flex-tite that is connected to the tank (Step 3).

Step 1

Step 3

Step 2

The electrical power rating for your Ultra UV2 unit is shown on the silver label located on the outside of the unit. 
(Fig. 3 on page 4)  Make sure the supplied power meets the units electrical requirements.  Connecting any 
power than that listed on the rating label will damage the unit and will VOID  your limited warranty.
120V 50/60Hz Ultra UV2 units
If your supply power is 120V 50/60Hz the label on your unit should match. At 120 volts, the power draw 
is 2.6 amps maximum for a 3 lamp system. This low power consumption makes operating this unit very 
economical. Your Ultra UV2 120V unit is supplied with a weatherproof power cord terminating with a 
3-prong grounded NEMA plug. An outdoor rated ground fault circuit interrupter must be installed in the 
electrical outlet serving the Ultra UV2 unit (subject to your local electrical codes).  

Do not cut the plug off the electrical cord and connect it directly to 
a 120V power source.  If this is done your warranty is voided and 
the U.L. listing is invalidated.

 

WARNING

Note: Some jurisdictions do not allow corded connections for these types of appliances. Check your local 
and national electrical codes. If hard wiring is required it must be done by a licensed electrical service 
person. The Ultra UV2 unit uses voltage sensitive ballast 120/230 volts. When wiring the unit 230 volts 
the black and white wires are wired hot and the green wire is ground. Amp draw on a 1 or 2 lamp unit is 
120V/230V 1.3A/.56A, 3 lamp unit is 120V/230V 2.6A/1.12A. Should the electrical cord become frayed or 
damaged in the future, unplug it from the power receptacle and replace it immediately. 
230V 50/60Hz Ultra UV2 Units
If you supplied power is 230V 50/60Hz the label on your unit should match. A junction box with 6” of lead 
wire is supplied for 230V Ultra UV2 Units.
Remember you CANNOT operate your Ultra UV2 on any power supply other than that indicated on the 
units silver label.

Have this work done by a licensed electrical technician.

NOTICE

 ELECTRICAL  BONDING
 Locate the bonding lug next to the power cable (Fig. 4). To reduce the risk 
of electric shock, this terminal must be connected to the bonding lug means 
provided in the electrical supply service panel with a continuous copper wire 
equivalent in size to the circuit conductors supplying this equipment. To reduce 
the risk of electric shock, connect the local common bond grid in the area of 
the pool or spa to this terminal with an insulated or bare copper conductor per 
national and local codes. The electrical installation is now complete.

Failure to silicone the 
wires in the connector 
could result in water from 

a leak in the unit leaking down the conduit and causing non-
warranted damage to other components.

 

WARNING

7

Содержание Ultra UV2

Страница 1: ...e risk of injury do not permit children to use this product unless they are closely supervised at all times Risk of electric shock Install at least 5 feet 1 5m from inside wall of pool hot tub or spa...

Страница 2: ...pplications other than those indicated above will void your warranty and could be harmful to your health or the health of others WARNING DANGER CAUTION WARNING NOTICE Indicates a hazardous situation w...

Страница 3: ...desired rate of sanitation Please note that the minimum posted flow rate must be met or exceeded to ensure proper system performance The water flow rate through the UV unit is governed by the piping...

Страница 4: ...rates of 3 lamp units which come with 4 unions and 4 plugs NOTE The use of multiple inlets outlets will require additional unions Use the plugs provided with the Ultra UV2 in the unused inlets and out...

Страница 5: ...uld be glued into the union tail pieces using an appropriate primer and ABS to PVC cement Inlet piping should be supported and should not rest solely upon the unions to avoid stressing or breaking the...

Страница 6: ...provides a path of least resistance for electrical current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The p...

Страница 7: ...nit subject to your local electrical codes Do not cut the plug off the electrical cord and connect it directly to a 120V power source If this is done your warranty is voided and the U L listing is inv...

Страница 8: ...or more then refer to the troubleshooting section of this manual on page 13 The filter gauge DOES NOT indicate the pressure in the UV unit NOTICE Do not look directly at the lamps Serious injury will...

Страница 9: ...e warranty Option 1 Removing the unit for the winter Turn off the power to the unit Disconnect the unions on the plumbing to ensure that the unit is completely drained Now with the power off disconnec...

Страница 10: ...rns will occur WARNING Do not touch the glass part of the lamp as body oils will create hot spots greatly shorten lamp life NOTICE 3 Disconnect all lamps by pressing the release tabs on connectors and...

Страница 11: ...reinstall the quartz tube place a new O ring 2 inches from the top of the outside of the quartz tube Fig 14 Gently lower the quartz tube into the unit until the O ring makes contact with the top of t...

Страница 12: ...tive rubber gloves and safety eye wear Do not handle a hot lamp or serious burns will occur WARNING Do not touch the glass part of the lamp as body oils will create hot spots greatly shorten lamp life...

Страница 13: ...e Ultra UV2 unit is operating at minimum of 2psi which is required to activate the pressure switch Please note that the filter gauge does not indicate the pressure in the UV unit c If the operating pr...

Страница 14: ...t on the same electrical circuit from any fault to ground the same as the electrical breaker protects the total electrical circuit from a short When the GFCI trips it is an indication that there is an...

Страница 15: ...tube seal or b a broken or cracked quartz tube Check the quartz tube seal and quartz tube as instructed in page 4 SPECIFICATION NOTICE Due to Paramount s commitment to continual product improvement al...

Страница 16: ...5 422 2009 06 2 Union Kits 9 005 422 2009 07 63mm Union Kits 10 005 422 3000 00 Replacement Housing 11 005 422 2009 08 2 Blanking Plug 12 005 422 2009 09 Quartz Tube With Seal Kit 13 005 422 2009 04 S...

Отзывы: