NORMAL OPERATION 
Configuration for Ultra UV2 units installed with bypass.
During normal operation the inlet valve #2 and 
outlet valve #3 should be completely open and the 
bypass valve #1 should be completely closed. 
Any 
partial opening of the bypass valve can drop the flow rate 
below the required minimum and cause damage to the 
Ultra UV2 unit. This instruction applies to all systems with 
a single speed or with a variable speed pump. This type 
of damage is not covered under the factory warranty.

WINTERIZE / SERVICE OPERATION 
Configuration for Ultra UV2 units installed with bypass.
Bypass operation is used for winterization or servicing/
replacing the Ultra UV2 unit. The bypass valve #1 
should be full open and the inlet valve #2 and the 
outlet valve #3 should be completely closed.  

WINTERIZATION OF YOUR ULTRA UV2 UNIT 
 If you are in a sub freezing climate you must 
winterize the Ultra UV2 using either option #1 or 
#2. Failure to do so will cause damage to the unit, 
which is not covered under the warranty. 

 Option  #1  - Removing the unit for the winter: Turn off 
the power to the unit. Disconnect the unions on the 
plumbing to ensure that the unit is completely drained. 
Now, with the power off, disconnect the unit from its 
power source and place the drained unit in a safe 
place that has a sustained temperature above freezing. 
Reinstall after the temperatures are considerably above 
freezing. 

 Option  #2  - Leaving the unit in place for the winter: Turn 
off the power to the unit. Disconnect the unions on the 
plumbing to ensure that the unit is completely drained. 
There is a cup in the bottom of your unit that the quartz 
tube nests in. This cup does not drain completely (Fig. 
30). To remove the water from this cup you must 
first remove the lamp array and quartz tube 
Fig. 
22 (See page 4). Turn the unit on its side with the 
unions facing down until all of the water has drained. 
Reconnect the unit, the quartz tube, lamps, and cover. 
You may store the lamps and quartz tube in a safe place.

Fig. 22

Unions

Cup

Filter

To Heater

or Pool

Pump

 

Bypass
Valve #1
Closed

Inlet Valve #2 Open

Outlet Valve #3 Open

Filter

To Heater

or Pool

Pump

 

Bypass
Valve #1
Open

Inlet Valve #2 Closed

Outlet Valve #3 Closed

Fig. 20

Fig. 21

Содержание Ultra UV2

Страница 1: ...e risk of injury do not permit children to use this product unless they are closely supervised at all times Risk of electric shock Install at least 5 feet 1 5m from inside wall of pool hot tub or spa...

Страница 2: ...pplications other than those indicated above will void your warranty and could be harmful to your health or the health of others WARNING DANGER CAUTION WARNING NOTICE Indicates a hazardous situation w...

Страница 3: ...desired rate of sanitation Please note that the minimum posted flow rate must be met or exceeded to ensure proper system performance The water flow rate through the UV unit is governed by the piping...

Страница 4: ...rates of 3 lamp units which come with 4 unions and 4 plugs NOTE The use of multiple inlets outlets will require additional unions Use the plugs provided with the Ultra UV2 in the unused inlets and out...

Страница 5: ...uld be glued into the union tail pieces using an appropriate primer and ABS to PVC cement Inlet piping should be supported and should not rest solely upon the unions to avoid stressing or breaking the...

Страница 6: ...provides a path of least resistance for electrical current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The p...

Страница 7: ...nit subject to your local electrical codes Do not cut the plug off the electrical cord and connect it directly to a 120V power source If this is done your warranty is voided and the U L listing is inv...

Страница 8: ...or more then refer to the troubleshooting section of this manual on page 13 The filter gauge DOES NOT indicate the pressure in the UV unit NOTICE Do not look directly at the lamps Serious injury will...

Страница 9: ...e warranty Option 1 Removing the unit for the winter Turn off the power to the unit Disconnect the unions on the plumbing to ensure that the unit is completely drained Now with the power off disconnec...

Страница 10: ...rns will occur WARNING Do not touch the glass part of the lamp as body oils will create hot spots greatly shorten lamp life NOTICE 3 Disconnect all lamps by pressing the release tabs on connectors and...

Страница 11: ...reinstall the quartz tube place a new O ring 2 inches from the top of the outside of the quartz tube Fig 14 Gently lower the quartz tube into the unit until the O ring makes contact with the top of t...

Страница 12: ...tive rubber gloves and safety eye wear Do not handle a hot lamp or serious burns will occur WARNING Do not touch the glass part of the lamp as body oils will create hot spots greatly shorten lamp life...

Страница 13: ...e Ultra UV2 unit is operating at minimum of 2psi which is required to activate the pressure switch Please note that the filter gauge does not indicate the pressure in the UV unit c If the operating pr...

Страница 14: ...t on the same electrical circuit from any fault to ground the same as the electrical breaker protects the total electrical circuit from a short When the GFCI trips it is an indication that there is an...

Страница 15: ...tube seal or b a broken or cracked quartz tube Check the quartz tube seal and quartz tube as instructed in page 4 SPECIFICATION NOTICE Due to Paramount s commitment to continual product improvement al...

Страница 16: ...5 422 2009 06 2 Union Kits 9 005 422 2009 07 63mm Union Kits 10 005 422 3000 00 Replacement Housing 11 005 422 2009 08 2 Blanking Plug 12 005 422 2009 09 Quartz Tube With Seal Kit 13 005 422 2009 04 S...

Отзывы: