FIBERGLASS INSTALLATION
Fiberglass Cover Assembly (Fig. 4)
1.
Prior to installing the Support, apply adhesive to the
non-ribbed side of the two notched gaskets.
2.
Align the gaskets with the alignment tabs and
screw holes, then press the gaskets onto the
Bulkhead Fitting and the Bulkhead Support.
3.
Align the SDX2 Vinyl/Fiberglass Support with
the alignment tab located at the top of the SDX2
Bulkhead Fitting.
(Fig. 3)
4.
Install five(5) self-tapping screws
(Fig. 5)
through
the SDX2 Bulkhead Support with the
T25 Security Screw Driver
(Fig. 6)
. Secure the
screws without over tightening.
5.
Align the SDX2 Cover with the SDX2 Support
holes.
6.
Install three (3) security screws through the SDX2
cover. Secure the screws without over tightening.
Fig. 5
Fig. 6
Fiberglass
Shell
Solid Gasket
Fig. 4
HYDROSTATIC FITTING:
The hydrostatic port inside the MDX-R3 Sump is
equivalent to a 2” Threaded Female Adapter and a 63mm Slip Fitting Outside the
MDX-R3 Sump. This port is for the purpose of a hydrostat only. Paramount recommends
the use of the 2” thread plug provided. Do not use check valves here that are prone to sticking open causing the
need to open the drain cover exposing a suction risk. If a hydrostat is not used, plug this port from bottom with pipe
and cap. Do not install any suction equipment (pump) to this port!
NOTICE
Содержание MDX-R3
Страница 12: ......