background image

Fig. 3

UP Arrow

Solid Gasket

Fiberglass Shell

Fig. 2

SUMP INSTALLATION TO SHELL

1.

   Apply sealing compound to top surface of MDX-R3 

sump flange.

2.

   From outside of pool shell, align sump with screw 

holes in mounting ring and sweep ninety pointing to  
side of pool shell.

3. 

 Install (12) 12 x 1” flat head screws every hole. 

(Fig. 1)

4.

   Secure 2nd Suction Outlet fitting through sidewall in 

desired locations.

FIBERGLASS SHELL

Fig. 1

SDX2 Fiberglass Installation

1.

   Select the installation location for the SDX2 drain. 

(Additional SDX2 drain may be used.)

2.

    

For Fiberglass Wall:

 Cut one 4.5” (11.43 cm) hole 

using a 4.5” (11.43 cm) hole saw.

3.

   Install the SDX2 Bulkhead Fitting with the “UP” arrow 

located at the top. 

(Fig. 3)

  For Fiberglass Shells: (Fig. 2)

 

  a.  

Place the solid Gasket with the smooth side 
against the Bulkhead Fitting flange.  (Silicone 
adhesive may be substituted for the Gasket if 
preferred.)

   b.

  Mount the SDX2 Bulkhead Fitting in the hole with 

the UP arrow at the top of each fitting.

   c.

 Secure with the SDX2 Nut.

4.

   Make plumbing connection between 2nd Suction 

Outlet and MDX-R3 Sump by connecting to side outlet 
of tee as shown in install methods 1on page 2.  Pipe 
must be equal diameter  to circulation line.

Содержание MDX-R3

Страница 1: ...R USE ON FLOOR Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ANSI APSP 16 2011 Compliant with ANSI APSP 7 2006 WARNING MDX R3 and SDX2 must be installed in accordance...

Страница 2: ...perly secured or missing because these conditions increase the chance of death or serious injury from entrapment If a drain cover is discovered damaged cracked broken loose clogged not properly secure...

Страница 3: ...ety begins with a professional design that includes a quality suction system installed by a certified contractor Certified builders will address the following issues when designing and installing a pr...

Страница 4: ...tion outlet being completely blocked the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump s for the specific suction system MDX R3 and SDX2 m...

Страница 5: ...S FOR SUCTION PLUMBING PER LOCAL CODE ENLARGED SUCTION ELEMENT METHOD 1 WITH DECK CANISTER AND MV FUSE IF NOT USING HYDROSTAT PLUG 50mm PORT 50mm SDX 2ND SUCTION OUTLET TO PUMP SKIMMER BYPASS 50mm TRU...

Страница 6: ...wn Note Canister requires 40mm equalizer line through pool wall Not Shown ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 2 PORT SDX 2ND SUCTION OUTLET 2 1 2 2 1 2 TO PUMP TRUNK LINE MUST BE SIZE...

Страница 7: ...DX2 drain Additional SDX2 drain may be used 2 For Fiberglass Wall Cut one 4 5 11 43 cm hole using a 4 5 11 43 cm hole saw 3 Install the SDX2 Bulkhead Fitting with the UP arrow located at the top Fig 3...

Страница 8: ...ithout over tightening 5 Align the SDX2 Cover with the SDX2 Support holes 6 Install three 3 security screws through the SDX2 cover Secure the screws without over tightening Fig 5 Fig 6 Fiberglass Shel...

Страница 9: ...is where the gasket will seal Fig 7 2 Glue gaskets to the face of the sump with RTV Silicon glue Be sure to line up all gasket holes with the corresponding hole in the sump Fig 8 TO POOL WALL SCREW H...

Страница 10: ...that need to be placed on the pool equipment if the pool is to be winterized and has a vent tube on any of the drains plumbed on the pool Attach the smaller label to the vent pipe where it terminates...

Страница 11: ...Coupler Reducer 4 X 2 3 005 282 0842 00 Screw Pack Fiber 19 pc 17 004 182 2212 XX SDX2 High Flow Safety Drain Fiberglass 2 pk XX Color Code 18 005 252 0821 00 Screw 10 X 1 1 4 TORX W PIN SS B 12 pcs...