INTENDED USE / PART NAMES

SAFETY PRECAUTIONS

.................................3

....................................4-11

..........................................12

INSTALLATION

MATTRESS (OPTIONAL)

ASSEMBLING THE BED

1. Board

OPERATION PROCEDURES

3. Casters

4. Bed side-rails

5. Accessory holders

..........................................16

......................................17-19

.....................................20

....................................23

1

2

3

4

5

1

8. Angle indicator

....................................22

Page

7. Restraint belt mounting holes

.............................21

10. Corner bumpers

.....................................21

CONTENTS

1. Operation overview

...................................14

2. Adjusting the base angle or the bed height

......................15

..............................22

9. Option attachment holes

6

6. Detaching the mattress base

.............................20

...........................................13

ACCESSORIES

2. IV pole

............................................25

3. Oxygen cylinder holder

..................................26

4. Foot spacer

.........................................27

Overbed table

........................................30

1. Recommended accessories table

..........................24

7

5. Foot spacer storage

...................................27

6. Orthopedic frame attachment

..............................28

7. Monitor table

.........................................29

PERIPHERAL EQUIPMENT

8

Содержание A5 Series

Страница 1: ...anual due to product improvements Values in the specification such as working range dimensions angles and mass are subject to normal manufacturing tolerances Besides some exemptions display purpose wo...

Страница 2: ...e 7 Restraint belt mounting holes 21 10 Corner bumpers 21 CONTENTS 1 Operation overview 14 2 Adjusting the base angle or the bed height 15 22 9 Option attachment holes 6 6 Detaching the mattress base...

Страница 3: ...GULAR INSPECTION AND DAILY MAINTENANCE TROUBLESHOOTING LONG TERM STORAGE AFTER SALES SERVICE 31 32 33 34 35 36 37 12 2 10 11 13 14 Page NOTE After pages 4 some part names described in the text are abb...

Страница 4: ...base Hip section base Accessory holder Base frame Footboard Knee section base Caster Leg section base Main frame Angle indicator p 13 p 13 p 17 19 p 21 p 20 p 16 Handle p 15 p 20 p 20 This bed is desi...

Страница 5: ...autions that must be strictly observed Indicates actions that may result in death or serious injury broken bones pressure or paralysis if the indication is ignored Indicates actions that may result in...

Страница 6: ...not to allow any part of the body to enter the gap in the side rail and the board If the bed is operated with a body part placed in the gap the part may get caught resulting in injury When the head o...

Страница 7: ...ulting in injury Be especially careful to check patients who might act in unexpected ways or cannot maintain their posture independently When leaving the bed area or temporarily taking your eyes off t...

Страница 8: ...njuly or the bed may get damaged or deformed Do not use the bed for infants or small children This product is not designed for infants or small children There is a risk of injuly caused by the infant...

Страница 9: ...lting in injury Do not repair or modify the product or its components This may create unintended gaps or may cause abnormal operation resulting in injury Inspect the bed regularly The product exhibits...

Страница 10: ...user s weight and incidental items including the mattress and options Do not place the bed on the inclination which angle is 6 degree or more The bed may tip over resulting in an injury Do not spray a...

Страница 11: ...causing damage or deformation Check around the bed before operating the bed The bed operations may damage objects located around the bed or may cause the bed to be damaged or deformed Secure at least...

Страница 12: ...be adjusted by at least two persons from both sides of the bed If only one person attempts to adjust the angle the person may get caught between the leg section base and main frame resulting in injury...

Страница 13: ...hPa to 1060hPa Locaitons with large amount of dust smoke salt sulfur or corrosive substances Locations with poor ventilation Locations exposed to vibrations or shocks including during transportaion Lo...

Страница 14: ...a risk of deformation of the board insertion parts Attaching Loosen the board stoppers on the bed Hold the grip of the board to lift it and properly insert the board insertion part into the board atta...

Страница 15: ...y parts have not entered the gap of the side rails or the space between the back section base and the frame There is a risk of getting caught resulting in injury When performing the height adjustment...

Страница 16: ...n used When stored When the handle is turned to its maximum limit it slips to prevent from going over the limit Pull the handle out fully before use Using the handle when it is not properly extended m...

Страница 17: ...toppers are on four casters on each corners of the bed When locking be sure to lock all casters Depressing the stopper locks the swiveling and rotation of the caster Prior to locking be sure that the...

Страница 18: ...of the side rail and push it Use the other hand to pull the operation lever toward you with pushing the side rail to opposite direction and while supporting the side rail lower the side rail until it...

Страница 19: ...he side rail until it clicks into place Push down the side rail to make sure that the side rail is locked Lowering the side rails Use one hand to hold the top of side rail and use the other hand to pu...

Страница 20: ...ry When raising side rails make sure that the side rails are locked If the side rails are not completely locked they may move unexpectedly resulting in injury Take care to prevent the intravenous tube...

Страница 21: ...ttachment method or dimensions depending on the manufactures use only those bags that are authorized for use with the bed When attaching a urine bag take care to prevent the bag or tube from getting c...

Страница 22: ...ueezed resulting in injury or the bed may get damaged or deformed When bedmaking or getting into out the bed be careful not to insert fingers or any body parts in the mounting brackets It may result i...

Страница 23: ...ent pay attention the board and option attachment holes will become tilted at an angle Option attachment hole 10 Corner bumpers Corner bumpers are at the four corners of the bed If the bed bumps the w...

Страница 24: ...Paramount Bed described below If an unsuitable mattress is used patients could get caught between the mattress and side rail and get injured Unsuitable mattresses exert a burden on the bed and may in...

Страница 25: ...l and on the carton box Do not use accessories other than those specified in this instruction manual This may create unintended gaps or may damage or deform the product resulting in injury Make sure t...

Страница 26: ...n injury Length adjustment of the sliding pipe should be kept within 70cm If the sliding pipe is pulled out too much it may come off resulting in an injury or damage Insert the IV pole into one of the...

Страница 27: ...ty is 15kg Do not insert the oxygen cylinder exceeding the load capacity because it may damage the oxygen cylinder holder resulting in injury The oxygen cylinder holder can be used by hanged on the he...

Страница 28: ...nd the side rail When using the extension frame function the foot spacer cannot be used For any queries please feel free to contact Paramount Bed or your distributor Insert the foot spacer into the op...

Страница 29: ...aching the orthopedic frame KA 86 Insert the orthopedic frame attachment into the option attachment hole on the foot side of the bed Insert a screwdriver into the orthopedic frame and tighten the scre...

Страница 30: ...als spills on the monitor table This may result in damage to the monitor table When lowering the table take care to prevent the fingers from becoming caught in the gap between the table and the frame...

Страница 31: ...e that can support patient to have a meal and work on light duty on the bed For any queries please feel free to contact Paramount Bed or your distributor Overbed table Note The overbed table can be us...

Страница 32: ...ay Authorised representative in the european community Do not stand on the side rail Manufacturer for CE mark Take care to prevent the patient s head from getting caught in the gap between the side ra...

Страница 33: ...s There must not be any peeling of labels and the text must be legible Operation details Inspection items Bed Unit Back raise operation p 14 to p 15 Proper operation can be achieved There must not be...

Страница 34: ...f there is abnormal noise Please feel free to contact Paramount Bed or your distributor to be lubricated The water adhesion to the bed or the mattress or moisture may cause corrosion abnormal noise or...

Страница 35: ...ther incidents must be inspected and repaired by Paramount Bed or your distributor Otherwise there is a risk of injury due to malfunctioning caused by deformation of the bed TROUBLESHOOTING 11 Product...

Страница 36: ...be exposed to high temperatures high humidity low temperatures dry or dusty conditions Store at a temperature between 10 and 50 humidity between 20 RH and 90 RH at 30 and atmospheric pressure between...

Страница 37: ...Side rail Headboard Footboard 85kg 100kg Operation Procedure Dimensions 350 20 10 to 700 20 10 mm Mattress base height Mattress base width Back raise Knee raise Manual Hi lo adjustment Manual Total le...

Страница 38: ...p 34 Date of purchase Details of fault or problem please provide as much detail as possible Your name organization address and phone number Consumable parts Mattress casters the rubber parts are cons...

Страница 39: ...38 NOTES...

Страница 40: ...2021 02...