pressure
2
.If the 2
nd
stage safety valve is released,
the 3
rd
stage valves do not close properly
2
.Check – replace valves
3
. 2
nd
or 3
rd
stage piston stuck
3
.Replace
4.
Blocked Sintered Filter of 2
nd
stage
separator (when 1
st
stage safety valve
opens)
*
4.
Clean or Replace
5.
Blocked Sintered Filter of 3
rd
– final
stage separator (when 2
nd
stage safety
valve opens)
*
5.
Clean or Replace
Compressor runs too
hot
1
.Insufficient supply of fresh cooling air
1
. Check location. Max Ambient
temperature under 40 ºC
2
.Intake or outlet valves are not closing
properly
2
.Check and clean valves, Replace if
necessary
3
.Wrong direction of rotation
3
.See arrow on the compressor and
remedy accordingly
4
.Low oil level
4
.Check oil level
Oil residue/Oil smell in
delivered air
1
.Improper maintenance of final filter
1
.Service filter - Renew BA cartridge
2
.Wrong type of oil
2
.Use right type of oil
3
.Activated carbon saturated
3
.Renew BA cartridge
4
.1
st
, 2
nd
, or 3
rd
stage piston rings worn
4
. Check - Replace
5
. Worn Cylinders
5
. Check - Replace
* Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 &
208704200.