User Manual -
Mistral M6&M8 -
04-2018 from s.n.1882761 edition
.
PARAMINA SA
– Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860
Fax: 0030 210 5575868, email:
- website:
www.paramina-compressors.com
26
General Service Instructions
o
CAUTION: Before any maintenance on the compressor, make sure there is not air inside, under pressure.
Every time you stop the compressor, ALWAYS open the manual drains so as to remove condensate.
o
Maintenance must always be done with the compressor stopped and disconnected from the mains
supply.
Maintenance
Operating hours
Every 20
hrs
Every
100 hrs
Every
200 hrs
Every
500 hrs
Every 1000
hrs
Every 2000
hrs
Every
6 mths
Every
12 mths
Check
V - Belt tension
1
st
X
Check oil level
1
& Condensate drain
system
Daily
Change of oil
2
1
st
X
X
Replace air intake cartridge
3
X
X
Replace the BA filter cartridge
2
X
4
X
Replace coalescing cartridge
3
X
X
Replace the
Sintered Filter Sponge -Oil Vapour
Exhaust
item 70a of page 40-41
X
Check Valves
X
Replace Valves
X
Replace pistons
and piston rings
X
Sintered Filter (Interstage & Final
stage Separator – see drawing at
page 48)
6
X
clean
X
replace
Service Kit 1000hrs
5
(p.n.190960000)
X
Service Kit 2000hrs
5
(p.n.190960100)
X
Replace filling hoses
X
Once per
5 years
ATTENTION
1.
Check every day the oil level and the general condition of the compressor. Check all connections for leakage.
2.
After 6 months, you have to replace the oil & BA filter cartridge, whether they have completed the required operating hours
or not. If the compressor is out of operation, you must also replace the oil before the winter season begins.
The proper quantity of oil, when you replace it, is
400ml for M6 models and 500 ml for M8 models.
Be careful to empty
the total quantity of used oil, otherwise the maximum oil indicator would be exceeded.
Never mix different types of oil.
The compressor unit is delivered filled with
PARAMINA HPS OIL p.n.112001000
(Synthetic oil).
3.
After 12 months, you have to replace coalescing cartridge and the air intake cartridge whether it has completed the required
operating hours or not.
4.
Measured @ 20
o
C ambient temperature.
5.
Service Kits, o-rings & Teflon may need to be replaced at undefined periods according to several factors.
6.
Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 & 208704200.