background image

 

 

 

8.

 

Connection and Setup 

 

8.1

 

  Inspection Checks 

 

Please inspect the unit to ensure that there is no damage to the external casing which could cause a 
malfunction of the device or cause a safety critical fault.  Any damaged units should be returned to Parallax 
Digital Technologies for inspection and testing. 

Please ensure that the DC Cables are securely fastened in the terminal block, and that the terminal block is 
correctly inserted into the switch power connector housing. 

 

8.2

 

  RJ45 Connections 

 

Ensure all required RJ45 Ports are connected correctly using CAT5e cable or better to the client devices.  
The Uplink port should be connected to the host device or network, and the access ports TP1-4 are 
available for other devices or connections. All cables should be solid copper and not CCA. 

 

8.3

 

  Power Up  

 

The Unit will automatically power up as soon as DC power is applied to the device. The Power Light will be 
illuminated and after approximately 1 second, all of the other LEDs will flash on and off to complete the 
initialization sequence.  Following this, the Port Status LEDs will display the current state of each of the 
ports. 

 

9.

 

Physical Dimensions 

 

 

All Dimensions are in mm 

 

Содержание PDT-NSU-0005-I

Страница 1: ...Operations Manual PDT NSU 0005 I Revision 1 0 August 2022...

Страница 2: ...t 4 5 Product Overview 5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 6 6 3 Power Supply Connector 7 7 Installation Procedures 8 7 1 DIN Rail Installation 8 7 2 Wall Mount Install...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 20 08 2022 01 JF Initial Release SC 20 08 2022...

Страница 4: ...ation Description AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device...

Страница 5: ...and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings and cautionary statements could lead t...

Страница 6: ...ting voltage range 12 48VDC making it suitable for a wide range of applications including solar and battery powered The device is designed for use in harsh industrial environments and incorporating a...

Страница 7: ...Status PWR Power Green OFF Unit Power Off ON Unit Power On L A Link Activity Yellow OFF No Connection ON Steady Connection ON Flashing Data Tx Rx SPD Link Speed Green OFF No Link ON Steady 100 Mbps 6...

Страница 8: ...tor Model No V V Power Input PDT NSU 0005 I GND 12 48VDC Note All Power Supplies should provide over current and short circuit protection and should have a capacity rating to meet the required output...

Страница 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Страница 10: ...ections Ensure all required RJ45 Ports are connected correctly using CAT5e cable or better to the client devices The Uplink port should be connected to the host device or network and the access ports...

Страница 11: ...ltage 12 48VDC Terminal Block Connector Power Consumption 6w Short Circuit Protection Auto Reset Reverse Polarity Protected MECHANICAL Dimensions 95mm x 70mm x 29mm Weight 250g Casing Aluminium Mounti...

Страница 12: ...For all technical enquiries regarding this product please contact our technical support team using the following email address support parallaxdigital co uk...

Отзывы: