background image

 

 

 

 

6.

 

Connectors and Indicators 

 

Front Panel 

 

 

 

6.1

 

  LED Indicators 

 

The Front Panel LEDs display the status of the switch and the associated port connections as 
indicated in the table below: 

 

LED 

Name 

Colour 

State 

Status 

PWR 

Power 

Green 

OFF 

Unit Power Off 

ON 

Unit Power On 

L/A 

Link Activity 

Yellow 

OFF 

No Connection 

ON 

 Steady 

Connection 

ON 

 Flashing 

Data Tx/Rx 

SPD 

Link Speed 

Green 

OFF 

No Link 

ON 

 Steady 

100 Mbps 

 

6.2

 

  RJ45 Ports 

 

The Front Panel has 5 RJ45 Ports and the Uplink Port is to be used to connect to the host network or 
device and is not PoE compatible.  The remaining 4 ports should be used as the access ports. 

 

 

Содержание PDT-NSU-0005-I

Страница 1: ...Operations Manual PDT NSU 0005 I Revision 1 0 August 2022...

Страница 2: ...t 4 5 Product Overview 5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 6 6 3 Power Supply Connector 7 7 Installation Procedures 8 7 1 DIN Rail Installation 8 7 2 Wall Mount Install...

Страница 3: ...1 Revision History Date Rev By Comments Checked Date 20 08 2022 01 JF Initial Release SC 20 08 2022...

Страница 4: ...ation Description AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device...

Страница 5: ...and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings and cautionary statements could lead t...

Страница 6: ...ting voltage range 12 48VDC making it suitable for a wide range of applications including solar and battery powered The device is designed for use in harsh industrial environments and incorporating a...

Страница 7: ...Status PWR Power Green OFF Unit Power Off ON Unit Power On L A Link Activity Yellow OFF No Connection ON Steady Connection ON Flashing Data Tx Rx SPD Link Speed Green OFF No Link ON Steady 100 Mbps 6...

Страница 8: ...tor Model No V V Power Input PDT NSU 0005 I GND 12 48VDC Note All Power Supplies should provide over current and short circuit protection and should have a capacity rating to meet the required output...

Страница 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Страница 10: ...ections Ensure all required RJ45 Ports are connected correctly using CAT5e cable or better to the client devices The Uplink port should be connected to the host device or network and the access ports...

Страница 11: ...ltage 12 48VDC Terminal Block Connector Power Consumption 6w Short Circuit Protection Auto Reset Reverse Polarity Protected MECHANICAL Dimensions 95mm x 70mm x 29mm Weight 250g Casing Aluminium Mounti...

Страница 12: ...For all technical enquiries regarding this product please contact our technical support team using the following email address support parallaxdigital co uk...

Отзывы: