Paragon ERC-2 Скачать руководство пользователя страница 5

5

PROGRAMiNG

The ERC-2 control initially powers up displaying 12:00 AM otherwise  

it will show the last configured selection (time or temperature).  

If a power outage occurs during normal operation, the control will 

maintain the correct time-of-day using a capacitor (batteries are not 

required). The time will be maintained for up to 100 hours when the 

capacitor is fully charged.
To initiate a 

Manual Defrost

, press and hold the MAN DEF key for  

3 seconds.
There are two levels of programming in the ERC-2. The first level of 

security will enable the user to set two parameters: Time-of-day (

CloC

and Setpoint temperature (

SEt

). The other level allows access to the 

other parameters.

Three buttons are used for the programming: SET, UP and DOwN

Figure. 13 – Display layout

To change Time-Of-Day and Setpoint temperature (First level) follow these steps:

Step 1

Press and hold set for 5 seconds. The display will show 

CloC.

Step 2

Press SET again to change the time-of-day.

Step 3

  

or

  

Press UP or DOwN until the correct time-of-day is displayed.

Step 4

Press SET to accept the new time.

Step 5

Press DOwN to go to the next parameter – Setpoint Temperature - 

SEt

 (cut out).

Step 6

Press SET to change the setpoint temperature.

Step 7

  

or

  

Press UP or DOwN to go to the desired setpoint. The range is – 40° to 60°F or –40° to 16°C.

Step 8

Press SET to accept the change.

Step 9

Press DOwN to exit the first level of programming.

Note 1:

  During programming, if no button is pushed during 30 seconds, the control will go back to the normal operating mode.  

This is valid for both programming levels.

Note 2:

 when changing the time, press and hold the MAN DEF button for 3 seconds to change the AM/PM mode.

To change the other parameters (Second level) follow these steps:

Step 1

 

or

  

Press and hold SET and DOwN for 10 seconds. The display will show 

dSPl.

Step 2

Press SET to change the parameter.

Step 3

  

or

  

Press UP or DOwN to change the options, time or temperature for the current parameter.

Step 4

Press SET to accept the new value.

Step 5

Press DOwN to go to the next parameter, then go back to Step 2. After the last parameter 

is displayed (

Alhi

), the display will go back to the normal operating condition.

Note:

 To scroll down the parameters without changing them, press the DOwN button.

Содержание ERC-2

Страница 1: ... the Clock It maintains the correct time of day for up to 100 hours Microprocessor Based Electronics High reliability and repeatability FCC Compliance This device complies with CFR 47 Part 15 Class A FCC requirements Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference th...

Страница 2: ...ation time amount of time for the defrost duration It also functions as a back up for temperature termination Defrost termination temperature temperature that will cause the defrost to terminate if reached before defrost duration time Fan start temperature temperature that will cause the fan to re start after defrost Setpoint Setpoint temperature cut out a setpoint temperature can be programmed to...

Страница 3: ...re in compliance with all federal state and local requirements including without limitation all requirements imposed under the National Electric Code and any applicable building codes CAUTION To prevent possible electric shock or equipment damage disconnect electrical power to the unit before and during installation DO NOT restore electrical power to the unit until the control is properly installe...

Страница 4: ...rsion 2 Connect the defrost device heater or hot gas solenoid to the terminal in the control Figs 10 and 11 3 Connect the wire from L1 120V AC or 208 240V AC line to the terminal marked as COM 4 Connect also the fan wires to the terminals marked as FAN 5 Use the alarm connections to connect an alarm to the control as shown in Figures 10 and 11 Figure 10 Load AC Input Connectors Quick Connects Figu...

Страница 5: ...displayed Step 4 Press SET to accept the new time Step 5 Press DOWN to go to the next parameter Setpoint Temperature SEt cut out Step 6 Press SET to change the setpoint temperature Step 7 or Press UP or DOWN to go to the desired setpoint The range is 40 to 60 F or 40 to 16 C Step 8 Press SET to accept the change Step 9 Press DOWN to exit the first level of programming Note 1 During programming if ...

Страница 6: ...from 0 to 59 minutes Compressor Run Time CPrn Time the compressor will run between defrosts Number of Defrosts nodF Number of defrosts per day from 0 to 8 0 means 1 defrost every 48 hours Defrost Start Time dEF1 8 Start time of each defrost Defrost Duration dEFd Defrost duration time back up for defrost termination temperature Range from 0 minutes to 4 hours Fan Delay FAnd Delay time for the fan a...

Страница 7: ...rature Alarm indicates that the temperature has gone above the high alarm setpoint For Error Codes 1 and 2 cut the power to the unit and correct the problem to reset the display For Codes 3 and 4 press the UP or DOWN button on the display to reset the error message If the display still shows the message the sensor must be replaced The Error Codes 6 and 7 will be automatically reset once the temper...

Страница 8: ... Ranco Paragon and Uni Line are trademarks of Robertshaw its subsidiaries and or affiliated companies All other brands mentioned may be the trademarks of their respective owners For Technical Service Telephone 1 800 445 8299 TechnicalService robertshaw com www uni line com www robertshaw com 2015 Robertshaw 10 15 7515010 Rev E 8 ...