2004
SIM2-A2-GZ40-00
Unpacking the SIM2000-24
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.
Unpack and inspect the SIM2000-24. If there is visible damage, do not attempt to
connect the device; contact your sales or service representative.
Installation in a 4000 or 12000 BAC
There must be a Multiplexer Uplink Module (MUM) installed in the Broadband
Access Concentrator (BAC) in order for interface modules to operate.
The 12000 and 12000E BACs are fourteen slot chassis. Slots 1–12 are
reserved for interface modules (such as the AIM24000), and the remaining
slots (13 and 14 in the 12000 and U1 and U2 in the 12000E) are reserved for
management modules.
The 4000 BAC is a five slot chassis; slots 1–4 are reserved for interface
modules and slot 5 is reserved for a MUM.
Interface modules are hot swappable. Installing or removing an interface module
while the chassis is powered up does not affect the operational status of other
interface modules within the chassis.
Procedure
1. Align the SIM2000-24 with the slot module guides of the chosen slot for
installation (slot 1–12 in the 12000 and 12000E or slot 1–4 in the 4000 and
4000E).
2. Slide the SIM2000-24 into the chassis. Do not use excessive force.
3. Secure the SIM2000-24 by tightening the fastening screws on the module
faceplate.
4. Verify that the PWR (Power) LED on the SIM2000-24 faceplate is illuminated.
!