SIM2-A2-GZ40-00

Unpacking the SIM2000-24

HANDLING PRECAUTIONS FOR 
STATIC-SENSITIVE DEVICES

This product is designed to protect sensitive components from damage 
due to electrostatic discharge (ESD) during normal operation. When 
performing installation procedures, however, take proper static control 
precautions to prevent damage to equipment. If you are not sure of the 
proper static control precautions, contact your nearest sales or service 
representative.

Unpack and inspect the SIM2000-24. If there is visible damage, do not attempt to 
connect the device; contact your sales or service representative.

Installation in a 4000 or 12000 BAC

There must be a Multiplexer Uplink Module (MUM) installed in the Broadband 
Access Concentrator (BAC) in order for interface modules to operate.

„

The 12000 and 12000E BACs are fourteen slot chassis. Slots 1–12 are 
reserved for interface modules (such as the AIM24000), and the remaining 
slots (13 and 14 in the 12000 and U1 and U2 in the 12000E) are reserved for 
management modules.

„

 The 4000 BAC is a five slot chassis; slots 1–4 are reserved for interface 
modules and slot 5 is reserved for a MUM.

Interface modules are hot swappable. Installing or removing an interface module 
while the chassis is powered up does not affect the operational status of other 
interface modules within the chassis. 

Procedure

1. Align the SIM2000-24 with the slot module guides of the chosen slot for 

installation (slot 1–12 in the 12000 and 12000E or slot 1–4 in the 4000 and 
4000E).

2. Slide the SIM2000-24 into the chassis. Do not use excessive force.

3. Secure the SIM2000-24 by tightening the fastening screws on the module 

faceplate.

4. Verify that the PWR (Power) LED on the SIM2000-24 faceplate is illuminated.

!

Содержание SIM2000

Страница 1: ... SIM2000 24 4 Installation in a 4000 or 12000 BAC 4 Connecting the SDSL Line 5 Default Settings 6 SIM2000 24 Management 6 Management Via the NMS 7 Management Via the CLI 7 Management Via SNMP 8 SIM2000 24 Parameters 9 RAM and NVRAM 10 Configuration Backup and Restore 10 LED Indicators 11 Regulatory Compliance for Class A Equipment 12 Important Safety Instructions 12 Warranty Sales Service and Trai...

Страница 2: ...censee shall not copy the Software except for a single archival copy 5 Except for the Product warranty contained in the manual the Software is provided AS IS and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED OR ORAL OR WRITTEN INCLUDING...

Страница 3: ...Agreement and the license granted under this Agreement shall be terminated in the event of breach by the Licensee of any provisions of this Agreement 9 Upon such termination the Licensee shall refrain from any further use of the Software and destroy the original and all copies of the Software in the possession of Licensee together with all documentation and related materials 10 This Agreement shal...

Страница 4: ...interface modules to operate The 12000 and 12000E BACs are fourteen slot chassis Slots 1 12 are reserved for interface modules such as the AIM24000 and the remaining slots 13 and 14 in the 12000 and U1 and U2 in the 12000E are reserved for management modules The 4000 BAC is a five slot chassis slots 1 4 are reserved for interface modules and slot 5 is reserved for a MUM Interface modules are hot s...

Страница 5: ...d a backup for the first and vice versa should either line become disabled Any two SIM2000 24 ports consecutive or not may be connected to an SNE2020 S or SNE2020G S subscriber unit to establish a loop bonded connection NOTE Any ports on the SIM2000 24 intended for a loop bonded connection with an SNE2020 S or SNE2020G S should be identically configured prior to connection Bonding ports with diffe...

Страница 6: ...ttings SIM2000 24 Management Once the SIM2000 24 has been installed line code bandwidth and all other configurations are software selectable Dependent upon the MUM model installed in your DSLAM the SIM2000 24 can be configured via the Command Line Interface CLI Simple Network Management Protocol SNMP or the web based Network Management System NMS For further information regarding SIM2000 24 manage...

Страница 7: ...Internet Explorer version 4 0 or higher or Netscape Navigator version 4 0 or higher 3 Enter the DSLAM s IP address into the address field at the top of your browser window Press the Enter key 4 Log in with your assigned username and password Note that General users have read only access for SIM2000 24 configuration you must log in as a Superuser Once you have logged in as a Superuser you may make ...

Страница 8: ... you will be able to utilize SNMP See the SNMP User s Guide for initial configuration instructions Procedure 1 Establish a connection with the MUM either directly through the Ethernet RJ45 MGMT port on the MUM faceplate or if the system has been so configured from a PC on your local network For direct connections verify that the MGMT LNK LED on the MUM faceplate is illuminated indicating the conne...

Страница 9: ...half of the bit rate thereby doubling transmission efficiency Speed There are nine bandwidth options for SIM2000 24 SDSL connections The default is 272 kbps Distance capabilities vary depending upon the type of line code being utilized Distances listed below assume the use of 26 American Wire Gauge AWG cable Connections made with cable of a greater gauge will link up at greater distances The units...

Страница 10: ...act even if the unit loses power unless deliberately cleared or reconfigured Configuration Backup and Restore Individual port configurations can be saved locally on your PC as a backup and or for use as a template for future configurations Once the SIM2000 24 has been configured as desired the settings can be uploaded through a Trivial File Transfer Protocol TFTP tool with a GET command and the fo...

Страница 11: ...a problem with the SDSL line No illumination No SDSL connection SDSL RX Receiving Flashing amber SDSL activity The port is receiving either data from the remote SDSL subscriber unit or statistical packets from the IP DSLAM management Solid amber Heavy Rx traffic The port is receiving large amounts of data from the remote SDSL subscriber unit No illumination No activity A link may exist but the por...

Страница 12: ...ique de la Classe A est conforme à la norme NMB 003 du Canada Europe This Class A product complies with European Norm EN55022 Caution In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation Important Safety Instructions UNITED STATES EMI NOTICE This equipment has been tested and found to comply wi...

Страница 13: ...sure to register your warranty at www paradyne com warranty Telephone Call our automated system to receive current information by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 1...

Страница 14: ...14 September 2004 SIM2 A2 GZ40 00 SIM2 A2 GZ40 00 ...

Отзывы: