4
September
2004
MUM2-A2-GZ40-00
Installing an Uplink Interface Module On the MUM2000-2
A Uplink Interface Module (UIM) provides the upstream network connection for the
BAC. Neither a BAC nor a MUM2000-2 can function without a UIM. Any of the
available Paradyne UIM models may be installed on a MUM2000-2.
Procedure
To install a UIM in the MUM2000-2:
1. Select a port on the MUM2000-2 for UIM installation. Either Port 1 or 2 may be
used. Although not required for operational purposes, two UIMs may be
installed on a MUM2000-2 to provide redundancy.
2. Remove the cover plate from the selected port.
CAUTION: Cover plates should be stored for possible future use. If a UIM is
removed from a MUM2000-2, it must be replaced with either another UIM or a
cover plate.
Do not operate a MUM2000-2 with an open UIM port.
3. Carefully slide the faceplate of the UIM under the lip of the MUM2000-2
faceplate at the selected port opening such that the UIM circuit board is face
down and the label shows through the port opening, with the UIM model name
along the right edge.
Uplink Interface Modules