![Paradyne Hotwire 8786 Скачать руководство пользователя страница 57](http://html2.mh-extra.com/html/paradyne/hotwire-8786/hotwire-8786_user-manual_3645823057.webp)
5. Testing
8786-A2-GB20-20
February 2001
5-5
G.703 DTE Loopback
A G.703 DTE Loopback loops the G.703 signal back to itself before the signal is
sent to the Framer.
Procedure
To run a G.703 DTE Loopback:
1. Position the cursor at the Start command next to G.703 DTE Loopback on the
Network & G.703 Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command.
4. Press Enter.
The G.703 DTE Loopback cannot be started when any other loopback test is
in progress.
CAP
DSL
Port
G.703
Port
CAP
E1
LIU
Framer
Framer
Transceiver
98-16000
All Ones
Содержание Hotwire 8786