4. Monitoring the Unit
8786-A2-GB20-20
February 2001
4-13
Status: Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
— Y: Remote alarm indication signal received at the G.703 interface
— L: Loss of signal detected at the G.703 interface
— E: Excessive error rate threshold exceeded
— F: Frame synchronization bit error detected
— V: Line code violation detected
— None: No significant events have occurred
Fields on this screen include:
This Field . . .
Contains . . .
Current Interval Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds
(15 minutes). This counter resets every 15 minutes.
Error Events Counter
A running total of CRC errors. Range 0–65535. This counter
resets when the near-end data is cleared.
Current Int
Performance data for the current 15-minute interval.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours).
Worst Interval
The number of the interval with the worst (highest) performance
data for both the near- and far-end statistics. If two or more
intervals are equal, the oldest interval is displayed.
Tot
A running total of the performance statistics.
Содержание Hotwire 8786
Страница 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8786 A2 GB20 20...
Страница 52: ...4 Monitoring the Unit 4 16 February 2001 8786 A2 GB20 20...
Страница 62: ...5 Testing 5 10 February 2001 8786 A2 GB20 20...
Страница 68: ...6 Messages and Troubleshooting 6 6 February 2001 8786 A2 GB20 20...
Страница 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8786 A2 GB20 20...
Страница 100: ...C Connector Pin Assignments C 2 February 2001 8786 A2 GB20 20...
Страница 102: ...D Technical Specifications D 2 February 2001 8786 A2 GB20 20...
Страница 112: ...Index IN 6 February 2001 8786 A2 GB20 20...