3. Configuration
8335-A2-GB20-A0
March 2005
3-35
4. Save the changes as prompted.
For . . .
Enter . . .
Seg Endpt (Models
8355 and 8375 only)
Enable or Disable to determine if the card will function as an
endpoint for ATM Operations, Adminstration and
Maintenance (OAM) loopbacks on the connection.
Enable
– To define the card as a segment loopback on this
connection. The line card will then check the location ID in a
loopback cell and loop the cell if the location ID is valid. If it
is not valid (the location ID does not match the
preconfigured ID or an all-ones ID), the cell will be dropped
(Default = Enable).
Disable
– To loop a cell only if the location ID matches the
preconfigured location ID. All other loopback cells are
passed to the next segment.
CSN
The Connection Serial Number (CSN) is an automatically
generated identifier for this connection that associates it
with a connection on the SCM card. It consists of the
following:
Slot Number (
01–18
for the 8820 BLC,
01–03
for the
8620 BLC)
Connection Type (
S
for Standard or
C
for Custom)
Port Number (
01–16
on the Model 8335,
01–12
on the
Model 8365, or
01–24
on the Model 8355, 8375,
or 8385)
A system-assigned 3-digit sequence number.
You must enter this value on the Cross Connect screen for
the SCM card (where it is labeled VID) to make a
connection through the system.
Содержание Hotwire 8335
Страница 6: ...Contents iv March 2005 8335 A2 GB20 A0...
Страница 14: ...1 About the ATM Line Cards 1 6 March 2005 8335 A2 GB20 A0...
Страница 70: ...3 Configuration 3 48 March 2005 8335 A2 GB20 A0...
Страница 108: ...5 Diagnostics 5 18 March 2005 8335 A2 GB20 A0...
Страница 132: ...Index IN 6 March 2005 8335 A2 GB20 A0...