2. Web Server Interface
8300-A2-GB20-00
April 2003
2-17
BPVS
Sets the Bipolar Violation Errored Seconds (BPVS) threshold. A BPVS is a
1-second period in which at least one bipolar violation occurred. The default is 0
seconds (Disabled).
OOFS
Sets the Out of Frame Seconds (OOFS) threshold. An OOFS is a 1-second
period in which a frame sync loss occurred. The default value is 5 seconds.
AISS
Sets the Alarm Indication Signal Seconds (AISS) threshold. An AIS is a
1-second period when unframed all ones are received. The default is 0 seconds
(Disabled).
RAS
Sets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by the
terminal equipment when an improper signal is received from the facility (or
upon receipt of unframed all ones). The default is 0 seconds (Disabled).
Reset Timer
Sets the Reset Timer threshold. This field is the contiguous number of seconds
that an alarm parameter must be clear before the alarm is reset. Applicable
values range from 000 through 900. A value of 000 means the alarm will never
be reset.
The CBR screens provide the user-activated buttons described below.
CAUTION:
Performance data will be lost upon power cycle or after
performing a Maintenance Reset/Restart.
Figure 2-14. Performance/Summary Screen
Button
Function
Submit
Sets any values that have been changed.
Clear Alarms
Resets the alarm conditions and counts to zero.
Performance
Displays a Performance/Summary screen that shows a current
count of the number of error events that have occurred over the
past 24 hours and the past 30 days.