![Paradyne Hotwire 8300 Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/paradyne/hotwire-8300/hotwire-8300_user-manual_754005106.webp)
3. VT100 Interface
3-4
April 2003
8300-A2-GB20-00
System Screen
The first option on the Main menu screen is the System screen (
Figure 3-3
). This
screen lets you view and set specific information about the unit in service.
Figure 3-3.
System Screen
The System screen displays the fields shown below.
The System screen displays two user-selectable prompts: Maintenance Reset,
and Save and Restart. Both are described in the paragraphs below.
Field
Description
Contact
Read/write field used to store the name of a point-of-contact for
system failure.
Name
Read/write field that holds the unit’s name.
Location
Read/write field that holds the unit's location.
FrameStart ID
Not used for ATM. Read/write field that holds the unit's ID that
uniquely identifies the unit and is used in the FrameStart
applications.
Blank Fields
Read/write fields for user-specific labels and values. Information
resides in non-volatile memory.
Time
Read/write field that holds the unit's internal time setting in
standard 24-hour HH:MM:SS format.
Date
Read/write field that holds the unit’s internal time setting in
standard 24-hour MM:DD:YY format.
New Admin
Password
New Read Only
Password
Lets you modify your Admin or Read-only password by typing in a
new password. Acceptable characters for use in a password are
digits 0–9 and letters A–Z and a–z, for a total of 62 distinct
characters.