10
4A. Prepare a Wall Jack for the SuperLine IAD – 2-Wire
Preparation for the SuperLine IAD depends on whether the customer premises is wired
with two wires or four.
Use the following procedure to prepare a wall jack for the SuperLine IAD in a 2-wire
configuration.
"
Procedure
1. Determine where the customer wants the SuperLine IAD installed.
2. Run new wiring from the NID or other entry point to the point where the SuperLine
IAD will be located.
3. Install a standard wall jack and connect the new wiring to the Pin 3 and Pin 4
positions.
4. Use the phone cord supplied with the SuperLine IAD to connect the LINE jack of
the SuperLine IAD to the new wall jack. No 2-line splitter is required for this type of
installation.
5. At the NID, reconnect the line to the local loop.
NID
3, 4
SuperLine 6040
Wall Jack Filter
Filtered
99-16551
3, 4
Standard Jack
Added for
SuperLine IAD
New Wiring
Added for
SuperLine IAD
LINE Jack
TST
LINE
ALM
PWR
ETHERNET
SuperLine IAD Installation In a 2-Wire Configuration