4-Wire Star

The SuperLine 6040 Wall Jack Filter replaces all wall jacks in a 4-wire star configuration
(where each wall jack is wired individually to the NID).

3, 4

2, 5

All Jacks
Replaced
with Filters

NID

99-16546

3, 4

2, 5

3, 4

2, 5

Filter Installation In a 4-Wire Star Configuration

Содержание Hotwire 6040

Страница 1: ...SuperLine Integrated Access Device IAD require a filter to isolate the voice frequency range from the SuperLine signal Basic Configurations 4 Wire Series The SuperLine 6040 Wall Jack Filter replaces t...

Страница 2: ...ack Filter replaces all wall jacks in a 4 wire star configuration where each wall jack is wired individually to the NID 3 4 2 5 All Jacks Replaced with Filters NID 99 16546 3 4 2 5 3 4 2 5 Filter Inst...

Страница 3: ...to the location of the SuperLine IAD in a 2 wire configuration NID 3 4 SuperLine 6040 Wall Jack Filter Filtered Unfiltered 99 16547 3 4 Standard Jack Added for SuperLine IAD New Wiring Added for Super...

Страница 4: ...line splitter if not adding a new wall jack for the SuperLine IAD Tools Required H Tone generator and probe or power source and continuity tester H Phillips screwdriver H Flat blade screwdriver H Wir...

Страница 5: ...ID or other entry point You must replace that wall jack with a Wall Jack Filter H If some or all wall jacks are wired in a star configuration that is more than one wall jack is wired directly to the N...

Страница 6: ...ack 2 If the wire ends are damaged clip off the damaged portion Strip the wires to expose 1 4I of bare copper 3 Remove the four screws from the faceplate of the filter and set aside the faceplate 4 Co...

Страница 7: ...ssembly to the wall box using the screws that held the old wall jack An engraving on the filter assembly UP shows the proper orientation 6 Fasten the faceplate to the filter assembly If any other wall...

Страница 8: ...r and install the SuperLine IAD there If the SuperLine IAD must be installed elsewhere run new wiring to a standard wall jack from the FILTER IN TIP and RING connections of the filter to the new wall...

Страница 9: ...UT RING 1 4 Black or White Orange to next jack FILTER IN TIP 2 2 Yellow or Orange White to next jack FILTER IN RING 2 5 White or White Green both from NID and to next jack TIP 3 3 1 Blue or Green Whit...

Страница 10: ...point where the SuperLine IAD will be located 3 Install a standard wall jack and connect the new wiring to the Pin 3 and Pin 4 positions 4 Use the phone cord supplied with the SuperLine IAD to connec...

Страница 11: ...the customer wants the SuperLine IAD installed 2 Plug a 2 line splitter into the wall jack at that location 3 Use the phone cord supplied with the SuperLine IAD to connect the LINE jack of the SuperLi...

Страница 12: ...reen or white blue and the Tip wire of Line 2 black or white orange Join the Ring wire of Line 1 red or blue white and the Ring wire of Line 2 yellow or orange white Reconnect the line to the local lo...

Страница 13: ...unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Avoid using a telephone other than a cordless type during an electric...

Страница 14: ...subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Warranty Sales Service and Training Information Contact your S...