background image

 24

Notices

!

WARNING:

THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS
FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES.

THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST
HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL
ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO

FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH
THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO

COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS
LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE
REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.THE

AUTHORITY TO OPERATE THIS EQUIPMENT IS CONDITIONED BY THE
REQUIREMENTS THAT NO MODIFICATIONS WILL BE MADE TO THE EQUIPMENT
UNLESS THE CHANGES OR MODIFICATIONS ARE EXPRESSLY APPROVED BY

PARADYNE.

!

WARNING:

TO USERS OF DIGITAL APPARATUS IN CANADA:THIS CLASS A DIGITAL APPARATUS
MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCEĆCAUSING

EQUIPMENT REGULATIONS.

CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES

DU RÈGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.

Government Requirements

Certain governments require that instructions pertaining to connection to the telephone
network be included in the installation and operation manual. Specific instructions are
listed in the following sections.

Note that 3810Plus and 3811Plus are the model names for the model numbers 3980
and 3981, respectively. The modems collectively are called 3800Plus modems.

United States – Notice to Users of the Telephone Network

1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label

that contains, among other information, the FCC registration number and ringer
equivalence number (REN) for this equipment. The label is located on the bottom
of the Model 3810Plus modem and on the circuit card assembly of the Model
3811Plus. If requested, this information must be provided to the telephone
company.

2. For the standalone modems, the Universal Service Order Code (USOC) for

Permissive mode is RJ11C; the Canadian equivalent is CA11. For the
carrier-mounted modem, the USOC for Permissive mode is RJ21X (Canadian
CA21A).

Содержание COMSPHERE 3800PLUS

Страница 1: ...COMSPHERE 3800Plus SERIES MODEMS MODELS 3810Plus and 3811Plus QUICK REFERENCE Document No 3980 A2 GL10 10...

Страница 2: ...to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning...

Страница 3: ...ment 3980 A2 GB30 COMSPHERE 3800Plus Series Modems User s Guide To request a paper copy of a Paradyne document H Within the U S A call 1 800 PARADYNE 1 800 727 2396 H Outside the U S A call 1 727 530...

Страница 4: ...e modem s rear panel Use a small screwdriver to fasten the cable to the modem 3 Connect the DB 25 P connector on the cable to the DB 25 S connector on the DTE Use a small screwdriver to fasten the cab...

Страница 5: ...f the modular cord into the leased line network interface 3 If you intend to use dial backup follow steps listed in Dial Line Connection section AC Power Supply Connection WARNING Power supplies from...

Страница 6: ...S 2 Connect the 3600 Hubbing Device to the network management system Refer to the 3600 Hubbing Device Feature Number 3600 F3 300 Installation Instructions for more information Installation for the 381...

Страница 7: ...ngle SDCP can control modems in up to eight carriers To install a 3811Plus modem into the carrier perform the following steps 1 At the rear of the carrier install the rear connector plate Make sure th...

Страница 8: ...es of one of the slots numbered 1 16 Slide the modem into the slot aligning the modem with the rear connector plate until the backplane connector and DTE connector seat firmly into the back of the car...

Страница 9: ...LEDs light up If the modem fails or an alarm condition exists the Alrm LED on the faceplate lights up or flashes It may be possible to run a diagnostic self test from the SDCP See Test Branch in the C...

Страница 10: ...Panel 3811Plus 142 125 Spkr Moves up one level from the current display Moves cursor or display to the left or right Returns display to Top Level menu Selects item displayed directly above the key F1...

Страница 11: ...ey to position the cursor on the slot selection entry 5 Press the F1 or F2 key until the slot number 1 16 you want appears on the LCD Ignore the AB designator that appears on the LCD since it is not a...

Страница 12: ...g Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect Pause Time NoAnswer Timout Fast Disconnect Long Space Disc No Carrier Disc No Data Disc NoDataDiscTrig Auto Make Busy MakeBusyViaDTR DTR A...

Страница 13: ...TR Alarm NetworkPosition CellulrRJ11Adpt Security EntryWait_Time VF_Prompt_Type DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answer_Secur Originate_Secur 98 15990b Does not a...

Страница 14: ...rvLine Download Code Secondary Prim data blckd ExitRem appears instead of Remote when using Remote Mode Does not appear in Remote Mode Security Set_Access_Ctrl Admin Password Reset_Security EditPassWd...

Страница 15: ...ailable Select Configure from the Top Level menu F1 Idle 28 8 Test Configure F2 F3 Scroll to the area you wish to load F1 Ld EditArea frm Factory F2 F3 2 Select Edit to choose the set of configuration...

Страница 16: ...Sync Leased Answer 3 UNIX Dial 4 Sync Leased Originate 5 Cellular Mobile if ETC installed 6 Cellular PSTN if ETC installed where n is one of the following configuration areas 0 Active Saved 1 Customer...

Страница 17: ...Speaker ON until carrier signal becomes active M2 Speaker always ON O Returns modem to Data mode from online Command mode P Enables Pulse Dial mode Qn Result Codes Q0 Enables result codes Refer to Res...

Страница 18: ...nect until DTR lowered by DTE AT COMMANDS continued Fn Loads Factory Configuration F0 Loads Async Dial factory configuration options into Active Operating configuration area F1 Loads Sync Dial factory...

Страница 19: ...te Digital Loopback test V 54 type L2 T7 Starts a Remote Digital Loopback test with a Pattern V 54 type L2 T8 Starts a Local Analog Loopback test with a Pattern V 54 type L3 T9 Starts a self test AT C...

Страница 20: ...s flow control of DTE Q1 Q4 Enables XON XOFF flow control Q2 Q3 Modem raises and lowers CTS to start and stop flow control Qn Flow Control of Modem Q0 Q2 Q4 Disables flow control of modem Q1 Q5 Enable...

Страница 21: ...1 11 CONNECT 4800 EC 22 12 CONNECT 9600 EC 23 16 CONNECT 12000 EC 24 13 CONNECT 14400 EC 25 17 CONNECT 16800 EC 26 15 CONNECT 7200 EC 27 5 CONNECT 1200 EC 29 14 CONNECT 19200 EC 37 37 CONNECT 21600 38...

Страница 22: ...LAPM_Discon S29 SDC Idle Fill 0 0 Flag_Fill 1 Mark_Fill S30 Sync DTE Rate 0 0 12800 bps 1 115200 3 96000 4 78800 5 72000 6 64000 7 57600 8 56000 9 48000 10 38400 11 28800 12 19200 13 14400 14 9600 15...

Страница 23: ...1 Enable S52 DTE LL CT141 0 0 Disable 1 Enable S53 V 54 Address 0 0 Disable or 1 34 S54 V 54 Device Type 0 0 Peripheral 1 Intermediate S55 Access from Remote 0 0 Enable 1 Disable S56 Remote Access Pas...

Страница 24: ...ing 0 0 Disable 1 Enable S84 AT Command Mode 0 0 Normal 1 No Error 2 No Strap or ERROR S85 Fast Disconnect 0 0 Disable 1 Enable S88 Straps When Disconnected 0 0 No Change 1 Reload 2 Reload No Change S...

Страница 25: ...an create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Co...

Страница 26: ...RENCE CAUSING EQUIPMENT REGULATIONS CET APPAREIL NUM RIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU R GLEMENT SUR LE MAT RIEL BROUILLEUR DU CANADA Government Requirements Certain governments re...

Страница 27: ...needs to be returned to the company service center for repair contact them directly for return instructions using one of the following methods Via the Internet Visit the Paradyne World Wide Web site...

Страница 28: ...ituations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equip...

Отзывы: