21
S-REGISTERS (continued)
Register
Description
Factory Setting
Range
S43
Train Time
0
0=Long; 1=Short
S44
Leased-Line Rate
27
1=14400(V.32bis); 2=12000(V.32bis);
3=9600(V.32bis); 4=7200(V.32bis);
5=4800(V.32bis); 6=2400(V22bis);
18=19200(V.32terbo); 19=16800(V.32terbo);
25=33600(V.34); 26=31200(V.34);
27=28800(V.34); 28=26400(V.34);
29=24000(V.34); 30=21600(V.34);
31=19200(V.34); 32=16800(V.34);
33=14400(V.34); 34=12000(V.34);
35=9600(V.34); 36=7200(V.34); 37=4800(V.34);
38=2400(V.34)
S45
Leased TX Level
0
0dBm–15dBm
S46
Auto Dial Backup
0
0=Disable; 1=Enable
S47
Auto Dial Standby
0
0=Disable; 1=15 minutes; 2=1 hour; 3=4 hours;
255=Test(2min)
S48
Leased-Line Carrier On Level
0
0=–43dBm; 1=–26dBm
S49
Buffer Disconnect Delay
10
0=Disable or 1–255 in 1-second increments
S51
DTE RL (CT140)
0
0=Disable; 1=Enable
S52
DTE LL (CT141)
0
0=Disable; 1=Enable
S53
V.54 Address
0
0(Disable) or 1–34
S54
V.54 Device Type
0
0=Peripheral; 1=Intermediate
S55
Access from Remote
0
0=Enable; 1=Disable
S56
Remote Access Password
00
00–99
1st and 2nd digits
S57
Remote Access Password
00
00–99
3rd and 4th digits
S58
Remote Access Password
00
00–99
5th and 6th digits
S59
Remote Access Password
00
00–99
7th and 8th digits
S61
CT111 Rate Control
0
0=Ignore; 1=Fallback 1; 2=Fallback 2
S62
V.25bis Coding
0
0=ASCII; 1=EBCDIC
S63
V.25bis Idle Character
0
0=Mark; 1=Flag
S64
V.25bis New Line Character
0
0=CR+LF; 1=CR; 2=LF
S66
NMS Call Messages
0
0=Call Connect & Progress; 1=Disable;
2=Call Connect Only; 3=Call Progress Only
S67
Directory Location 1 Callback
0
0=Disable; 1=Enable
S69
Make Busy Via DTR
0
0=Disable; 1=Enable
S74
Network Position
0
0=Tributary; 1=Control
S75
Network Management Address
255
0–255 (001–256)
S76
Dial Autorate
0
0=Enable; 1=Disable; 2=Start at 4800;
3=Start at 9600