F-1
3610-A2-GB46-60
December 1996
Technical Specifications
Technical Specifications
F-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specifications
The 3600 Series DSUs can be used as a Local Area
Data Set (LADS) to provide a point-to-point link between
two devices. The network facility is a direct 4-wire
crossover connection without using a digital service.
Tables F-1 through F-6 list the technical specifications
for the following:
•
LADS maximum connection distance requirements
(Tables F-1 and F-2)
•
3600 Series DSU (Tables F-3 and F-4)
•
3600 Hubbing Device for use with a Model 3610
DSU only (Table F-5)
•
Async Terminal for use with a Model 3610 DSU
only (Table F-6)
Table F-1
LADS Connection Distances for
Models 3610
-A3-xxx and 3611-A3-xxx or Lower
Wire Diameter (AWG)
Data Rate
(kbps)
19 Gauge
(.0359
I
or
.9122 mm)
22 Gauge
(.0253
I
or
.643 mm)
24 Gauge
(.0201
I
or
.511 mm)
26 Gauge
(.0159
I
or
.404 mm)
2.4
20.0 mi
(32.2 km)
16.6 mi
(26.7 km)
12.7 mi
(20.5 km)
9.4 mi
(15.1 km)
4.8
19.4 mi
(31.2 km)
12.7 mi
(20.5 km)
9.6 mi
(15.4 km)
7.1 mi
(11.5 km)
9.6
15.2 mi
(24.5 km)
9.7 mi
(15.6 km)
7.3 mi
(11.7 km)
5.6 mi
(9.0 km)
19.2*
11.8 mi
(19.0 km)
7.5 mi
(12.1 km)
5.7 mi
(9.2 km)
4.2 mi
(6.8 km)
38.4
11.2 mi
(18.0 km)
6.5 mi
(10.5 km)
4.6 mi
(7.4 km)
3.2 mi
(5.1 km)
56
9.2 mi
(14.8 km)
5.4 mi
(8.7 km)
3.8 mi
6.2 km)
2.8 mi
(4.5 km)
64
9.2 mi
(14.8 km)
5.4 mi
(8.7 km)
3.8 mi
(6.2 km)
2.8 mi
(4.5 km)
* Power level is –10 dBm.