ACCULINK 317x E1 DSU/CSU

3-28

December 1996

3170-A2-GB20-20

8. If you selected NET the channels allocated to the

Network E1 interface are displayed. Line 1
displays the 31 channels for the Network E1
interface, while Line 2 displays what is allocated
to the DS0 channel shown in Line 1. Pressing the

  or  

  key scrolls the channels onto the screen

in groups of three.

F1

N1

N2

N3

D2

D3

Prt1

F2

F3

If you selected DTE, the channels allocated to the
DTE Drop/Insert interface are displayed. Line 1
displays the 31 channels for the DTE Drop/Insert
interface, while Line 2 displays what is allocated
to the DS0 channel shown in Line 1.

F1

D1

D2

D3

N1

N2

F2

F3

Allocating Data Ports

Assign a specific port (Prt1 and Prt2 for Model 3172,

Prt1 through Prt4 for Model 3174) to DS0 channels on
either the Network interface or the DTE Drop/Insert
interface by using the configuration options. The
following methods are available to assign DS0 channels to
the port:

Block – Allows a block of contiguous channels to be

assigned by specifying a data port rate and an initial DS0
channel (the first DS0 channel in a block of DS0
channels). The number of channels assigned is determined
by the port rate. Only those initial DS0 channel numbers
that provide enough bandwidth (based on the port’s data
rate) are displayed on the screen. These channels are
automatically assigned to the destination E1 interface
when the initial DS0 channel is selected.

Chan – Individually selects the DS0 channels to

allocate to the data port. The data port rate is
automatically determined based on the number of
channels selected.

Once a port is selected, you have access to

configuration options to complete the port allocation
procedure. These configuration options enable you to,

Assign the selected port to the desired interface

Select the desired method for channel allocation

Select the port rate and starting channel (if the
allocation method is block)

Select the specific channels if the allocation method
is by individual channel

These configuration options are explained in detail in

Appendix C.

To select the data port,

1. Press F3 to select Cnfig from the top-level menu

screen.

2. Select the configuration option set to be copied

into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.

3. Press F1 to select Edit.

4. Press the  

  key from the Edit screen to display

the Chan selection.

5. Select Chan.

F1

Edit:DTE
Port

NET

Chan

F2

F3

6. From the Channel Config screen, press the  

key to scroll the ports onto the screen.

F1

Channel Config:
Dsply

Clear

DTE

F2

F3

Содержание ACCULINK 317x E1

Страница 1: ...ACCULINK 317x E1 DATA SERVICE UNIT CHANNEL SERVICE UNIT OPERATOR S GUIDE Document No 3170 A2 GB20 20 December 1996...

Страница 2: ...oned herein are the trademarks service marks registered trademarks or registered service marks of their respective owners COPYRIGHT 1996 Paradyne Corporation All rights reserved This publication is pr...

Страница 3: ...ks Refer all servicing to qualified service personnel 6 General purpose cables may be provided with this product Special cables which may be required by the regulatory inspection authority for the ins...

Страница 4: ...TO PART 15 OF THE FCC RULES THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT THIS EQUIPMENT GENERATES...

Страница 5: ...for use within certain voltage limits as amended by Directive 93 68 EEC Directive 89 336 EEC Council Directive of 3 May 1989 on the approximation of the laws of the member states relating to Electro...

Страница 6: ...es 2 5 Cabling Examples 2 8 Power Up Self Test 2 9 3 Operation Overview 3 2 Using the Front Panel 3 2 Displaying Unit Identity 3 8 Displaying LED Conditions 3 10 Selecting the DTE Drop Insert or Data...

Страница 7: ...ice Health and Status 4 3 Network Performance Reports 4 5 Alarms 4 9 SNMP Traps 4 10 Troubleshooting 4 11 Test Jacks 4 13 Test Commands 4 14 Remote Loopback Tests 4 14 Local Loopback Tests 4 15 Test P...

Страница 8: ...k Management Protocol SNMP if you want your E1 DSU CSU to be managed by an SNMP manager Related Document 7800 A2 GB20 ACCULINK 3100 Series Open Management Application for HP OpenView User s Guide Refe...

Страница 9: ...es and fractional E1 network applications The E1 DSU CSU series of products consists of a Model 3172 DSU CSU 2 port and a Model 3174 DSU CSU 4 port Differences between these models are discussed where...

Страница 10: ...standard SNMP manager The company provides an SNMP application that runs on a Hewlett Packard HP OpenView network management platform For more information refer to the ACCULINK 3100 Series Open Manage...

Страница 11: ...button keypad three Function and four directional keys Twelve light emitting diodes LEDs Six test jacks Rear Panel The E1 DSU CSU rear panel contains the connectors and switches required for the opera...

Страница 12: ...RX 75 TX NETWORK CAUTION AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR E1 NETWORK Figure 1 2 Model 3172 Rear Panel 495 14294 02 POWER AUX PORT COM PORT DTE PORT 3 PORT 4 PORT 1 PORT 2 CLOCK IN...

Страница 13: ...format of CCITT Recommendation G 703 and the frame structure of CCITT Recommendation G 704 NETWORK 120 Provides an unkeyed modular jack for a 120 ohm balanced network interface NETWORK 75 TX RX Provid...

Страница 14: ...to provide an interface between the E1 digital network and the customer premises equipment The E1 DSU CSU is connected to the customer premises equipment through one of the synchronous data ports PORT...

Страница 15: ...d Access Application Example FRACTIONAL NETWORK LAN ROUTER LAN ROUTER LAN ROUTER 496 14313 03 DSU CSU DSU CSU DSU CSU LAN ROUTER Figure 2 3 Fractional E1 Application Example 496 14700 01 DACS MOBILE S...

Страница 16: ...the AUX port to an external LAN Adapter for Ethernet SNMP connectivity Figure 2 7 Daisy chaining the COM port of one device to the AUX port of the other to provide SNMP connectivity Figure 2 8 Remote...

Страница 17: ...onnection through a LAN Adapter to SNMP LAN ROUTER ETHERNET SNMP PPP 496 14549a LAN ADAPTER SNMP PPP SNMP PPP NETWORK DSU CSU DSU CSU DSU CSU SNMP NMS Figure 2 8 LAN Adapter and Daisy Chaining for SNM...

Страница 18: ...Optional Power Sources The E1 DSU CSU is typically powered by the ac power module Use the following procedures only if you want to use an optional dc power source Using the optional dc power cable the...

Страница 19: ...he following procedure To install the 48 Vdc single source power supply 1 Connect the black and red wires to the 48 Vdc return source 2 Connect the green wire to a suitable earth ground 3 Connect the...

Страница 20: ...Vdc power supply 1 Connect the black wire to the 48 Vdc return source B 2 Connect the red wire to the 48 Vdc return source A 3 Connect the green wire to a suitable earth ground 4 Connect the orange wi...

Страница 21: ...r earth shield connection for the 75 ohm RX interface This switch must be set to open when using the 120 ohm interface POWER AUX PORT COM PORT DTE PORT 1 PORT 2 CLOCK IN 120 75 75 120 RX SHIELD OPEN E...

Страница 22: ...l LED blinks ON and Off continuously F1 Self Test In Progress F2 F3 2 All the LEDs then start to flash simultaneously in the pattern twice ON then Off Then the LCD begins to flash characters and numbe...

Страница 23: ...s Type s 3 17 Configuring SNMP Traps 3 18 Enabling SNMP Trap Messages 3 18 Selecting the Number of Trap Managers 3 19 Configuring a Destination for SNMP Traps 3 19 Configuring DS0 Channels 3 20 Displa...

Страница 24: ...nt Panel The E1 DSU CSU front panel Figure 3 1 consists of an LCD a keypad test jacks and 12 LEDs NOTE You can display a graphical representation of the E1 DSU CSU front panel on an attached PC see Ap...

Страница 25: ...second line displays options and responses When a response is required select from the options displayed directly above the Function keys F1 F2 F3 make your choice by pressing the corresponding Funct...

Страница 26: ...ll keys to bring the additional options onto the screen F1 F2 F3 Test Jacks Six test jacks are located on the front panel Figure 3 4 These are described in the Test Jacks section in Chapter 4 Maintena...

Страница 27: ...s the signal being received from the network ON A recoverable signal is being received from the network OFF The signal cannot be recovered from the network a Loss of Signal condition exists OOF Yellow...

Страница 28: ...n the received DTE Drop Insert signal ON An alarm condition LOS LOF EER RAI AIS exists on the received DTE Drop Insert signal Use the Device Health and Status command to determine the alarm type OFF N...

Страница 29: ...th ones and zeros are being received from the synchronous data DTE RXD Yellow Monitors activity on interchange circuit BB CCITT 104 Received Data This is data sent to the synchronous data DTE from the...

Страница 30: ...t Test Cnfig F2 F3 2 Press the key three times on the Status screen to bring the ID selection onto the front panel LCD F1 Status DevHS STest Perf F2 F3 3 Press F3 to select ID from the Status screen F...

Страница 31: ...election appears on the front panel LCD F1 Control Rel LED ClrReg F2 F3 4 Select CID F1 Control Reset CID DL F2 F3 5 Use the and keys to position the cursor under the desired character You must enter...

Страница 32: ...on F1 Status DevHS STest Perf F2 F3 3 Select LED from the Status screen F1 Status Perf TStat LED F2 F3 4 From the Select LEDs screen press the Function key that corresponds to E1 or the port for which...

Страница 33: ...y presented with menu choices that are consistent with the current configuration and operational state of the E1 DSU CSU invalid combinations of configuration options do not appear For example menus d...

Страница 34: ...ct the configuration option set to be copied into the Edit area by using the appropriate Function key Use the scroll keys if necessary F1 Load from Activ Cust1 F2 F3 3 Press F1 to select Edit F1 Choos...

Страница 35: ...F1 Save Edit to Activ Cust1 F2 F3 Selecting Copying to a Specific Port For the E1 DSU CSU you have the capability of selecting a specific port to configure and then copying the configuration options f...

Страница 36: ...cting the Port The SNMP manager or network device e g a router can be directly connected to the communications COM port An external LAN Adapter can be connected to either the COM port or the auxiliary...

Страница 37: ...top level menu screen 2 Select the configuration option set to be copied into the Edit area by using the appropriate Function key Use the scroll keys if necessary 3 Press F1 to select Edit 4 Press th...

Страница 38: ...e elapsed time Full negotiation of escape characters The E1 DSU CSU implementation of PPP does not support Link Quality Reports LQR compression encryption Password Authentication Protocol PAP or Chall...

Страница 39: ...Gen from the SNMP Config screen F1 SNMP Config Gen Trap F2 F3 7 Press F1 Next until the CommunityName1 configuration option appears 8 Press F2 Edit to edit the community name The factory default commu...

Страница 40: ...f the network The SNMP Trap configuration option must be enabled for trap messages to be sent over the communications link You must specify the number of SNMP managers that are to receive traps from t...

Страница 41: ...trap manager specified This configuration option is displayed for the number of trap managers specified by the Number of Trap Managers configuration option To configure an IP address for the SNMP trap...

Страница 42: ...nected to the corresponding channel e g D1 to N1 D2 to N2 etc To allocate DS0 channels begin by defining the logical channel configuration for the Network interface and then the DTE Drop Insert interf...

Страница 43: ...25 N26 N27 N28 N29 N30 N31 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 D19 D20 D21 D22 D23 D24 D25 D26 D27 D28 D29 D30 D31 PRT 1 PRT 2 PRT 3 PRT 4 PORTS DROP INSERT INTERFACE NETWOR...

Страница 44: ...N30 Prt2 N31 Prt3 Allocations D1 D31 indicates allocation to DTE Drop Insert channels Prt1 Prt4 indicates allocation to synchronous data ports DTE Drop Insert Interface Drop Insert Channel Allocation...

Страница 45: ...N20 N21 N22 N23 N24 N25 N26 N27 N28 N29 N30 N31 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 D19 D20 D21 D22 D23 D24 D25 D26 D27 D28 D29 D30 D31 PRT 1 PRT 2 PRT 3 PRT 4 PORTS DROP IN...

Страница 46: ...Prt2 N30 Prt2 N31 Prt3 Allocations D1 D31 indicates allocation to DTE Drop Insert channels Prt1 Prt4 indicates allocation to synchronous data ports DTE Drop Insert Interface Drop Insert Channel Alloc...

Страница 47: ...or Dn 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Select Multiple Assign To NET DTE Prt1 Prt3 Prt4 Assign By Block Chan Port 2 If Assign By Block Port Rate Nx64...

Страница 48: ...lot Nn or Dn 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Select Multiple Assign To NET DTE Prt1 Prt2 Prt3 Assign By Block Chan Port 4 If Assign By Block Port Ra...

Страница 49: ...e DS0 channel is allocated to the DTE Drop Insert interface DS0 channel n where n can be any number from 1 through 31 To display the DS0 channel allocation 1 Press F3 to select Cnfig from the top leve...

Страница 50: ...rate Only those initial DS0 channel numbers that provide enough bandwidth based on the port s data rate are displayed on the screen These channels are automatically assigned to the destination E1 inte...

Страница 51: ...Rate F1 Assign By Block Next Block Chan F2 F3 3 Use the or key to scroll the desired port rate onto the screen Rates scroll in groups of three Available selections depend on the current base rate sele...

Страница 52: ...ate a port press the Function key under that port number Pressing the Function key under channels assigned to other ports has no effect F1 N1 N2 Next Prt1 Prt2 F2 F3 NOTE N16 will not appear if time s...

Страница 53: ...screen F1 TS16 Rsvd Data Rsvd F2 F3 10 From the DTE Channels screen press F2 to select Assign F1 DTE Channels TS16 Assign F2 F3 11 Press the Function key below the network channel desired Each time t...

Страница 54: ...work E1 interface Or select DTE to clear all DS0 channels assigned to the DTE Drop Insert interface Or select a port to clear all assignments for that data port F1 Clear Channel NET DTE Port1 F2 F3 Pr...

Страница 55: ...internal clock The clock source configuration options enable you to select either the Network E1 interface a synchronous data port the internal clock the DTE Drop Insert interface or an external cloc...

Страница 56: ...above For more information on configuration options refer to Appendix C Configuring for External Timing To configure the E1 DSU CSU for external timing 1 Press F3 to select Cnfig from the top level me...

Страница 57: ...er interface regardless of what screen was displayed at the previous active user interface F1 DSU E1 CEPT Stat Test Cnfig F2 F3 The inactive interface displays the following message when a Function ke...

Страница 58: ...he Ctrl selection on the top level menu screen F1 DSU E1 CEPT Stat Test Cnfig F2 F3 2 Press F3 to select Ctrl from the top level menu screen 3 From the Control screen press the key until the Reset sel...

Страница 59: ...est or Ctrl branches are available All functions on the Stat branch are available All functions on the Cnfg branch are available for display but they cannot be used to save to a configuration area Act...

Страница 60: ...s 4 15 Starting a Line Loopback 4 16 Starting a Payload Loopback 4 16 Starting a DTE Loopback 4 17 Starting a Repeater Loopback 4 17 Starting a Data Channel Loopback 4 18 Starting a Data Terminal Loop...

Страница 61: ...ble 4 1 Self Test Health Messages Message Description Passed No problems were found during power up CPU fail The central processing unit failed internal testing DTE E1 fail The unit failed to internal...

Страница 62: ...riority message is displayed The message DSU Operational appears when there are no other messages To display device health and status 1 Press F1 to select Stat from the top level menu screen F1 DSU E1...

Страница 63: ...condary clock Second Clk fail The primary clock and the secondary clock have failed Timing for the E1 DSU CSU is provided by the internal clock OOF at Prtn An Out Of Frame has been detected on data po...

Страница 64: ...that collect performance data for the previous 8 hour period Registers shown on the front panel LCD are listed in Table 4 3 Port data is updated in 15 minute intervals After 15 minutes the current in...

Страница 65: ...ork registers from the E1 DSU CSU via the ClrReg command in the Control branch of the front panel menu To clear the user performance registers 1 Press the key on the top level menu screen to bring the...

Страница 66: ...The number of unavailable seconds for the current interval An unavailable second is any one second interval when service is unavailable The maximum is 900 seconds The total number of unavailable secon...

Страница 67: ...once during the interval The event is identified by a letter as follows R A Remote Alarm Indication has been received on the network interface L Loss Of Signal has occurred on the network interface E...

Страница 68: ...face Alarm Cleared An Excessive Error Rate at the Network Interface Remote Alarm Indication signal received at the x Interface where x is either Network or DTE Alarm Cleared Remote Alarm Indication si...

Страница 69: ...zed an enterprise specific event See Table 4 4 for enterprise specific traps These traps are set by the Entp Trap configuration option Link Traps identify the condition of the communications interface...

Страница 70: ...p Insert cable problem 2 No signal being transmitted from the DTE 1 Check that the DTE Drop Insert cable is securely attached at both ends 2 Check the DTE status Message OOF at Net appears 1 Incompati...

Страница 71: ...the DTE cable is securely attached at both ends A failure message appears followed by an 8 digit code Internal E1 DSU CSU problem Record the 8 digit code then contact your field service representativ...

Страница 72: ...that allows a signal to be inserted toward the network by external test equipment The signal is inserted on the DTE side of the E1 DSU CSU NET Out Network Out A break in test jack that interrupts the...

Страница 73: ...est Combination appears To send a Data Channel Activation or Deactivation loopback sequence to the far end E1 DSU CSU 1 Press F2 to select Test from the top level menu screen 2 From the Test screen pr...

Страница 74: ...transmitted on the network interface to initiate LLBs see Appendix C Configuration Options The data port configuration option NET DCLB controls whether the E1 DSU CSU responds to inband V 54 commands...

Страница 75: ...8 for valid loopback test combinations Starting a Payload Loopback The Payload Loopback command PLB loops the received signal on the network interface back to the network The signal is looped back as...

Страница 76: ...F3 3 From the Loopback screen press once to display the DLB selection on the screen F1 Loopback Abort LLB PLB F2 F3 4 Press F3 to select DLB F1 Loopback LLB PLB DLB F2 F3 Test Started appears on Line...

Страница 77: ...occurs after the data passes through the port circuitry but before it is sent out the data port To perform a Data Channel loopback 1 Press F2 to select Test from the top level menu screen 2 From the...

Страница 78: ...F2 F3 5 From the DTLB screen press the Function key for the port for which you want to perform the data terminal loopback Use the scroll keys if necessary F1 Loopback DTLB Prt1 Prt2 Prt3 F2 F3 Test St...

Страница 79: ...ll be running You can use the TStat branch of the menu to view the test status to determine if the abort was successful Test Patterns Use the Test Pattern commands to send and abort transmission of te...

Страница 80: ...keys if necessary F1 Send Name Prt1 Prt2 Prt3 F2 F3 The Test Started screen appears F1 Send Name and Dest Test Started F2 F3 If the E1 DSU CSU is already sending the test pattern you selected the mess...

Страница 81: ...or QRSS or F2 for 511 F1 Patterns Mon QRSS 511 F2 F3 5 From the Monitor screen press the Function key that corresponds to the port for which you want to monitor a test pattern Use the scroll keys if n...

Страница 82: ...he menu to view the test status to determine if the abort was successful 5 From the Abort screen press the Function key that corresponds to the network or port for which you want to abort a test patte...

Страница 83: ...p Test screen To do this when the LCD is alternating the Lamp test screens press any Function key Otherwise follow Steps 1 through 3 for starting a Lamp test F1 Lamp Test Abort Start F2 F3 2 From the...

Страница 84: ...n Port n Port n is in a data terminal loopback 1 8 Test Active A 1 in 8 test pattern is being sent on the network interface QRSS on Port n A QRSS test pattern is being sent to the network on the chann...

Страница 85: ...Activ Cust2 Ctrl Rel ClrReg Reset CID LED DL DTE Prt1 Prt2 Prt3 Prt4 PLB DLB RLB LLB Abort DCLB DTLB Abort Send Mon QRSS 1in8 511 QRSS 511 NET Prt1 Prt2 Prt3 Prt4 Far Near Activ Cust1 Cust2 Fact Prtn...

Страница 86: ...c 0 25A POWER CONSUMPTION AND DISSIPATION 16 0 watts 55 0 Btu per hour at 115 volts ac power 12 0 watts 41 Btu per hour at 24 and 48 Vdc dc power DTE Drop Insert INTERFACE Physical Interface Framing F...

Страница 87: ...abeling CLOCKING SOURCES E1 network interface synchronous data port internal clock DTE Drop Insert interface or external clock PHYSICAL DIMENSIONS Height Width Depth 3 90 inches 10 0 cm 7 63 inches 19...

Страница 88: ...e C 2 Network Interface Configuration Options The Network Interface configuration options configure the Network E1 interface on the E1 DSU CSU Table C 3 Channel Configuration Options The Channel confi...

Страница 89: ...e High Density Bipolar 3 coding format Extrn DLB Disab Next Enab Disab Prev DTE Loopback on External Contact Allows the initiation and termination of a DTE Loopback DLB by an external contact For more...

Страница 90: ...rk Initiated DCLB Allows the initiation and termination of a Data Channel Loopback V 54 loop 2 by the receipt of a V 54 DCLB actuate sequence or DCLB release sequence from the network or far end E1 DS...

Страница 91: ...ort is clocked using an internal clock provided by the E1 DSU CSU synchronized to the clock source specified by the clock source configuration options in the General configuration option group or an e...

Страница 92: ...t is cleared with less than 1 984 errors in ten seconds 10E 5 10E 5 Threshold For example at 1984 kbps EER is declared if more than 1 189 CRC5 errors are detected in a 60 second period It is cleared w...

Страница 93: ...sabled NOTE If the local E1 DSU CSU is configured to maintain far end performance statistics then the remote E1 DSU CSU must be configured to send near end performance statistics Mgmt Link Disab Next...

Страница 94: ...nd cannot be terminated within the network Disab Disables the FDL Management Link SNMP Enables the FDL Management Link for SNMP NOTE This configuration option is not available and does not appear if E...

Страница 95: ...Specifies that TS16 is available for data Rsvd Specifies that TS16 is reserved for signaling information NOTE Changing this configuration option from one selection to the other Data or Rsvd deallocate...

Страница 96: ...t1 from the Channel Config screen Prt2 Prt3 and Prt4 appear for the 3174 Use this feature to designate a port as a backup port You can attach an external backup device to Prtn and manually assign the...

Страница 97: ...is set to that synchronous data port the external device must provide a clock of 8 kbps less than the expected data port rate For example if you select 64 kbps the external clock source must supply a...

Страница 98: ...nel is allocated to the Network E1 interface DS0 channel n where n is a number from 1 to 31 You cannot modify this value on this screen Dn This DS0 channel is allocated to the DTE Drop Insert interfac...

Страница 99: ...DSU CSU Failure of the clock specified by the Primary Clock Source selection results in automatic fallback to the secondary clock source When this occurs this selection synchronizes all internal timin...

Страница 100: ...ary port of an another 31xx Series device NOTE SNMP and ASCII selections can be made using the ifAdminStatus MIB object up SNMP testing ASCII NOTE The Daisy selection requires the use of a customer su...

Страница 101: ...Next 7 8 Prev Communication Port Character Length Configures the character length 7 or 8 bits for the communication port NOTE This configuration option must be set to 8 if the communication port is us...

Страница 102: ...port is not to be used SNMP Specifies that the auxiliary port is to be used as the management link to an external SNMP manager via an external LAN Adapter Daisy Specifies that the auxiliary port is t...

Страница 103: ...the communication port Disab Prevents alarm messages for any alarm conditions NOTE Alarm messages are only sent to the communication port if the Com Use configuration option is set to ASCII otherwise...

Страница 104: ...ntact Clear Allows you to clear the system contact CommunityName1 public Next Edit Clear Prev Community Name 1 Specifies the first of two community names that are allowed to access this unit s Managem...

Страница 105: ...2 is used Write access is allowed for all objects specified as read write in the MIB RFCs Read access is allowed for all objects specified as either read only or read write IP Adr Next Edit Clear Prev...

Страница 106: ...you to edit and or display the subnet mask for the communication port Clear Allows you to clear the subnet mask for the communication port The subnet mask is set to 000 000 000 000 If the subnet mask...

Страница 107: ...the class of the IP address Class A 255 000 000 000 Class B 255 255 000 000 or Class C 255 255 255 000 Def Netwk None Next None Com Aux FDL EDL1 EDL2 EDL3 EDL4 Prev Default Network Destination Specifi...

Страница 108: ...ux The Trap Manager n network destination is the auxiliary port This selection only appears if the Aux Use configuration option is set to SNMP or Daisy FDL The Trap Manager n network destination is th...

Страница 109: ...ntly configured trap manager s Both Sends trap messages for linkUp and linkDown events to the currently configured trap manager s NOTE This configuration option is not available and does not appear if...

Страница 110: ...Ones Enab Disab Net Options Value NET Frame CRC4 noCRC Mgmt Link Disab SNMP Circuit Ident Edit Clear General Options Value Pri Clk Src NET DTE Prt1 Prt2 Prt3 Prt4 Int Ext Sec Clk Src NET DTE Prt1 Prt...

Страница 111: ...Enab Disab Err Rate 10E 4 10E 5 10E 6 10E 7 10E 8 10E 9 Near end Disab Maint Send Both Far end Disab Maint Mgmt Link Disab SNMP Prt3 Options Value Port Type E530 V 35 RS449 Base Rate Nx64 Nx56 NetDCL...

Страница 112: ...1 Allocations D1 D31 indicates allocation to DTE Drop Insert channels Prt1 Prt4 indicates allocation to synchronous data ports DTE Drop Insert Interface Drop Insert Channel Allocation D1 D2 D3 D4 D5 D...

Страница 113: ...ect One If Assign By Chan Time Slot Nn or Dn 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Select Multiple Assign To NET DTE Prt1 Prt3 Prt4 Assign By Block Chan P...

Страница 114: ...t One If Assign By Chan Time Slot Nn or Dn 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Select Multiple Assign To NET DTE Prt1 Prt2 Prt3 Assign By Block Chan Por...

Страница 115: ...ss 2 Read R W IP Adr Edit Clear NetMask Edit Clear Com IP Adr Edit Clear Com NetMask Edit Clear Com Link PPP SLIP Aux IP Adr Edit Clear Aux NetMask Edit Clear Def Netwk None Com Aux FDL EDL1 EDL2 EDL3...

Страница 116: ...35 Cable Interface D 10 EIA 530A to X 21 Cable Interface D 12 Power Input Connector D 14 Optional DC Power Cable D 14 External Clock Interface D 15 Overview The E1 DSU CSU is shipped with a power mod...

Страница 117: ...face or an RJ48C 8 position unkeyed modular connector Table D 1 for a 120 ohm balanced interface The E1 120 ohm network interface adapter cable is shown in Figure D 1 Table D 1 E1 120 Ohm Balanced Int...

Страница 118: ...ion of Appendix C The DTE Drop Insert cable Figure D 2 is typically supplied by a DTE vendor It is made of shielded twisted pair wires 22 AWG The cable connector is a DB15 plug Be sure to connect the...

Страница 119: ...NOTE For daisy chaining an AUX port to a COM port a customer supplied 8 pin to 8 pin straight through cable is required and the appropriate configuration options Com Use and Aux Use must be set to Dai...

Страница 120: ...PC cable is shown in Figure D 3 and the COM port to terminal printer cable is shown in Figure D 4 NOTE For daisy chaining an AUX port to a COM port a customer supplied 8 pin to 8 pin straight through...

Страница 121: ...ACCULINK 317x E1 DSU CSU D 6 December 1996 3170 A2 GB20 20 Figure D 3 COM Port to PC Cable Figure D 4 COM Port to Terminal Printer Cable...

Страница 122: ...ved Data BB 104 From DSU CSU 3 A 16 B Request to Send CA 105 To DSU CSU 4 A 19 B Clear to Send CB 106 From DSU CSU 5 A 13 B Received Line Signal Detector CF 109 From DSU CSU 8 A 10 B DCE Ready CC 107...

Страница 123: ...22 6 24 5 23 8 26 7 25 9 27 12 13 31 11 19 14 10 20 17 35 18 29 30 SHIELD TD A TD B RD A RD B TXC A TXC B RXC A RXC B RTS A RTS B CTS A CTS B DTR RLSD A RLSD B DSR SIG COMMON RL LL RCV COMMON TT A TT...

Страница 124: ...m DSU CSU 6 A 24 B Request to Send RS 105 To DSU CSU 7 A 25 B Clear to Send CS 106 From DSU CSU 9 A 27 B Receiver Ready RR 109 From DSU CSU 13 A 31 B Data Mode DM 107 From DSU CSU 11 A 29 B Terminal R...

Страница 125: ...2 14 3 16 15 12 17 9 4 5 8 6 7 24 11 20 21 18 25 A P S R T Y AA V X C D F E B U W H N L NN SHIELD TD A TD B RD A RD B TXC A TXC B RXC A RXC B RTS CTS RLSD DSR SIG COMMON TT A TT B DTR RL LL TM SHIELD...

Страница 126: ...Send 106 From DSU CSU D Data Channel Received Line Signal Detector 109 From DSU CSU F Data Set Ready 107 From DSU CSU E Data Terminal Ready 108 1 2 To DSU CSU H Transmit Signal Element Timing DTE Sour...

Страница 127: ...the X 21 interface shown in Table D 8 2 14 3 16 17 9 4 19 8 10 7 24 11 2 9 4 11 6 13 3 10 5 12 8 7 14 TD A TD B RD A RD B RXC A RXC B RTS A RTS B RLSD A RLSD B SIG COMMON TT A TT B TD A TD B RD A RD B...

Страница 128: ...102 8 Transmitted Data 103 To DSU CSU 2 A 9 B Received Data 104 From DSU CSU 4 A 11 B Request to Send 105 To DSU CSU 3 A 10 B Data Channel Received Line Signal Detector 109 From DSU CSU 5 A 12 B Tran...

Страница 129: ...he power cable is a 14 5 foot 18 AWG stranded cable The connector is terminated at one end with a 6 position connector The other end of the cable is terminated with a bare wire that should be connecte...

Страница 130: ...lock connector pinouts are in Table D 10 A cable diagram is shown in Figure D 9 This is a customer supplied cable Table D 10 External Clock Connector Signal Pin Number Shield 1 Clock RS422 only 2 Cloc...

Страница 131: ...prise MIB E 15 Correlation between Menu Commands and SNMP Objects E 16 Overview This appendix describes the Management Information Base MIB objects that are supported by the E1 DSU CSU and provides a...

Страница 132: ...ative identification of the network management subsystem contained in the unit This object displays the following object identifier 3172 1 3 6 1 4 1 74 1 14 2 2 5 3174 1 3 6 1 4 1 74 1 14 2 2 6 System...

Страница 133: ...des the textual information about the interface Each interface displays a text string as shown below Network E1 Network E1 E1 DSU CSU Hardware Version CCA number for the CSU board DTE E1 DTE E1 E1 DSU...

Страница 134: ...n the COM port testing 3 The SNMP management link is inactive on the COM port the COM port can be used for proprietary ASCII functions Interface Group ifOperStatus Object ifEntry 8 This object specifi...

Страница 135: ...P Group MIB II The IP Group objects are supported by the E1 DSU CSU for all data paths which currently are configured to carry IP data to or from the E1 DSU CSU including the COM AUX EDL and FDL All o...

Страница 136: ...ation ipRouteMetric3 ipRouteMetric4 ipRouteMetric5 Defaulted to 1 as specified in the MIB ipRouteNextHop Defaulted to 0 0 0 0 The following read only objects must not be specified in the set PDU used...

Страница 137: ...by the E1 DSU CSU UDP Group MIB II The User Datagram Protocol UDP Group objects are fully supported by the E1 DSU CSU Transmission Group MIB II Objects in the transmission group are supported on the...

Страница 138: ...the network interface only An error status is returned if access is attempted for the DTE Drop Insert interface Near End Group dsx1LineType Object dsx1ConfigEntry 5 This object corresponds to the NET...

Страница 139: ...Signal LOS condition has persisted for more that 2 5 seconds dsx1LoopbackState 128 The near end of the E1 interface is in a loopback state dsx1Other Failure 4096 An Excessive Error Rate EER has been...

Страница 140: ...nterval Table Objects dsx1IntervalEntry The following DS1 interval table objects are provided for the network interface only Objects in the table that are not listed are not supported and will return...

Страница 141: ...ding network channels e g D1 to N1 etc otherwise an error is returned to the SNMP manager RS 232 like MIB RFC 1317 The rs232 object defined by RFC 1317 is supported for all of the synchronous data por...

Страница 142: ...e input speed of the AUX or COM port is the currently configured speed Setting of this value for the AUX or COM port causes the configured port speed to be changed General Port Table rs232PortOutSpeed...

Страница 143: ...2 The port uses an external clock Input Signal Table RS 232 like MIB This table contains entries for the input signals that can be detected by the unit for each of the synchronous data ports Input Sig...

Страница 144: ...511 test pattern on a synchronous data port Start stop the DCLB DTLB loopback test on a synchronous data port The following object identifiers control tests on the interface noTest Stops the test in...

Страница 145: ...synchronized on the requested pattern Where these object identifiers are defined as follows wellKnownCodes OBJECT IDENTIFIER ifExtensions 5 none OBJECT IDENTIFIER wellKnownCodes 1 inSyncNoBitErrors OB...

Страница 146: ...E1 dsx1LossOfSignal dsx1LossOfFrame dsx1RcvFarEnd dsx1RcvAIS dsx1OtherFailure Stat DevHS LOS at DTE OOF at DTE RAI at DTE AIS at DTE Read the dsx1LineStatus object for DTE E1 dsx1LossOfSignal dsx1Loss...

Страница 147: ...m the System Group Test Rlpbk DCLBUP Prtn Set IfExtnsTestType for port n to testSendV54Up Test Rlpbk DCLBDN Prtn Set IfExtnsTestType for port n to testSendV54Down Test Lpbk LLB Test Lpbk Abort LLB Set...

Страница 148: ...Display rs232SyncPortClockSource for port n to internal or external Cnfig Activ Edit NET NET Frame Set Display dsx1LineType for NET E1 to dsx1E1 or dsxE1 CRC Cnfig Activ Edit NET Mgmt Link Set Display...

Страница 149: ...ilable on full E1 links not fractional E1s Check with the service provider to be sure that the FDL is end to end i e not terminated at an intermediate point within the network Interconnected 31xx Seri...

Страница 150: ...3 6 1 0 C O M S P H E R E 3 6 1 0 CO MS PH ER E 361 0 CO MS PH ER E 361 0 CO MS PH ER E 361 0 CO MS PH ER E 361 0 135 18 1 3 135 18 1 4 135 18 1 5 135 18 1 7 135 18 1 6 135 18 1 1 135 18 1 1 135 18 40...

Страница 151: ...ase 3 1 or higher MS DOS 3 3 or higher and at least 4 MB of RAM A VGA color monitor with VGA adapter or higher resolution is required A mouse is also required The following procedures must be performe...

Страница 152: ...oxes The Com Port field needs to contain the actual communications port name as recorded in the Windows information file INI The Speed field needs to contain one of the following communications speeds...

Страница 153: ...SU CSU 24 48 Vdc 3174 A1 510 107765232 E1 120 Ohm Network Interface Cable 8 pin modular to DB15S 3100 F1 517 107782245 Modular COM Port to PC Cable 8 pin modular to DB9S 3100 F1 550 406941542 COM Port...

Страница 154: ...is put ASCII American Standard Code for Information Interchange A 7 bit code which establishes compatibility between data services ASCII terminal printer Devices that can be attached either locally or...

Страница 155: ...CHAP Challenge Authentication Protocol character A letter figure number punctuation or other symbol CID branch Customer Identification branch or the E1 DSU CSU menu tree client A device that receives...

Страница 156: ...e network DCLB Data Channel Loopback Loops the data received from the network interface for all DS0 channels allocated to the selected port back to the network default A preset value that is assumed t...

Страница 157: ...organization providing standards for the data communication industry EIA 530A An EIA standard for a high speed 25 position DCE DTE interface Enterprise MIB MIB objects unique to Paradyne devices ente...

Страница 158: ...ion of networks that predominantly use the TCP IP protocol internetwork An interconnected collection of networks also called an internet IP address Internet Protocol address The address used by the SN...

Страница 159: ...system used for monitoring and controlling network devices node A connection or switching point on the network object SNMP A specific item within a Management Information Base MIB OOF Out Of Frame An...

Страница 160: ...when power is removed register A part of the device s memory that holds stored values Rel branch Release branch of the E1 DSU CSU menu tree reset A reinitialization of the E1 DSU CSU that occurs at p...

Страница 161: ...ission that is synchronized by timing signals Characters are sent at a fixed rate TCP IP Transmission Control Protocol Internet Protocol The dominant protocol in the worldwide Internet time slot The a...

Страница 162: ...f wireless communications The transmission of voice and or data over the airwaves XTXC External Transmit Clock V 24 circuit 113 1in8 Test A test pattern consisting of a one 1 followed by seven zeros o...

Страница 163: ...condition front panel LED indication 3 6 Performance Report message 4 8 troubleshooting 4 12 C cabling equipment list H 1 examples 2 8 pin assignments D 1 D 15 Chan Channel Configuration branch examp...

Страница 164: ...ion table C 2 option worksheet C 23 DTE Drop Insert interface channel allocation procedure 3 20 3 26 configuration options C 2 failure message 4 2 front panel LED indications 3 6 functional descriptio...

Страница 165: ...dition front panel LED indication 3 5 3 6 Performance Report message 4 7 LOFC Loss Of Frame Count report 4 8 loopback front panel LED indication 3 5 local 4 15 4 20 abort 4 19 4 20 data channel loopba...

Страница 166: ...ecifications B 2 Port Configuration branch example of use 3 13 3 14 in the menu tree A 1 option table C 3 C 6 option worksheet C 24 power input cabling example 2 8 connector 1 4 1 5 D 14 consumption B...

Страница 167: ...20 F 1 switch rear panel 1 4 1 5 synchronous data port See PORT 1 4 interface T technical specifications B 1 temperature operating B 2 storage B 2 Test branch example of use 4 14 4 26 in the menu tre...

Отзывы: