Troubleshooting and Maintenance
5-33
9161-A2-GH30-20
September 1997
Aborting All Tests
Use the Abort All Tests selection from the Test menu to abort all tests running on
all interfaces, with exception to Network- or DTE-initiated loopbacks. To abort
individual tests that are active, see
Starting and Stopping a Test
on page 5-32.
"
Procedure
To abort all tests on all interfaces:
1. Follow this menu selection sequence:
Main Menu
→
Test
2. Select Abort All Tests and press Return.
Command Complete appears when all tests on all interfaces have been
terminated.
NOTE:
Abort All Tests does not interrupt DTE-initiated loopbacks.
Determining Test Status and Results
Current test status and results are available on the:
H
Test screen from where you execute the test
H
System and Test Status screen
H
NMS
H
Test LED
For more information on interpreting results and messages, refer to
Chapter 5,
Maintenance and Troubleshooting, in the User’s Guide.
Hot Swapping of APMs
The T1 access unit allows you to insert and remove APM cards and their
matching I/O cards without powering down the unit or interrupting data on the
network or on other APMs. The T1 access unit automatically recognizes when an
APM is inserted or removed, and can display the configuration option settings
and MIB objects applicable to the APM that was inserted or removed.
NOTE:
You do not have access to screens and configuration options that are not
valid for the given configuration, nor can you preconfigure or predelete a
configuration for an APM prior to inserting it in the housing. To see
configuration options for an inserted APM, you must exit the configuration
screen, then reenter it.