10
7610-A2-GN10-20
November 1997
Table 3.
Model 7610 DSU LADS (Local Area Data Set) Connection Distances
Wire Diameter (AWG)
Data Rate
(kbps)
19 Gauge
(.0359
I
or
.9122 mm)
22 Gauge
(.0253
I
or
.643 mm)
24 Gauge
(.0201
I
or
.511 mm)
26 Gauge
(.0159
I
or
.404 mm)
56
10.84 mi
(17.45 km)
6.4 mi
(10.3 km)
4.50 mi
(7.24 km)
3.34 mi
(5.37 km)
64
10.69 mi
(17.2 km)
6.06 mi
(9.76 km)
4.47 mi
(7.2 km)
3.20 mi
(5.15 km)
Start-up Checklist
The User’s Guide contains details regarding the Asynchronous Terminal Interface
(ATI). When setting up the ATI:
-
Refer to
About the SNMP DSU, Chapter 1, to determine the management
configuration(s) to manage the DSU with one of the user interfaces:
— Locally through the Terminal port or by NMS connection through the
Management port
— Remotely via Telnet session, through the Management port or the
In-Band Management Channel (IMC)
— Out-of-band, using an external modem through the Terminal port or the
Management port
-
Set-up the Identity and Call Setup administrative screens. Refer to
Startup,
Chapter 3.
-
Establish security and Login IDs; refer to
Security, Chapter 4.
-
Decide on an IP addressing scheme. Refer to
IP Addressing, Chapter 5.
-
Determine whether you want ASCII alarms and/or SNMP traps generated.
Refer to
Messages and Troubleshooting, Chapter 8.
-
Change configuration option settings. Refer to
Configuration Option Tables,
Appendix A, and
Worksheets, Appendix B.
-
Provide management connectivity with SNMP and enterprise-specific MIBs.