Paradyne 7610 SNMP DSU Скачать руководство пользователя страница 10

 9

7610-A2-GN10-20

November 1997

Table 1.

Model 7610 DSU Technical Specifications (2 of 2)

Item

Specifications

Network Compatibility

ANSI T1.410–1992 and 
AT&T Technical Reference
62310–1993

56 and 64 kbps meeting desired loop loss

IP Connectivity

Up to 20 routes

NMS Compatibility

SNMP Network Manager

MIB II Object Groups
Supported

H

ICMP group

H

Interfaces group:

– DDS network

– DTE Data port

– Terminal port

– Management port

H

IP group

H

SNMP group

H

System group

H

TCP group

H

Transmission group:

– DDS network – DDS Enterprise MIB

– DTE Data port – RS-232-Like MIB

– Terminal port – RS-232-Like MIB

– Management port – RS-232-Like MIB

H

UDP group

Table 2.

Model 7610 DTE Port Clock Rate

In-Band Management

Line Operating Rate

In-Band Management
Channel (IMC) Rate

56 Kbps

64 Kbps (CC or LADS)

0 (IMC disabled)

56,000 bps

64,000 bps

1,600 bps

54,400 bps

62,400 bps

4,000 bps

52,000 bps

60,000 bps

8,000 bps

48,000 bps

56,000 bps

Содержание 7610 SNMP DSU

Страница 1: ...CHANGE Please note that the area code for Paradyne Corporation in Largo Florida has changed from 813 to 727 For any Paradyne telephone number that appears in this manual with an 813 area code dial 72...

Страница 2: ...ng the Adobe Acrobat Reader The User s Guide is provided on diskette in Portable Document Format PDF It can be browsed or printed using the Adobe Acrobat Reader The Reader is available at no charge at...

Страница 3: ...m to either the H Management port H Terminal port Standard crossover EIA 232 cable with DB25 plug connectors on both ends A Router s AUX port to the Management port Standard straight through EIA 232 c...

Страница 4: ...and ventilated site that is free from environmental extremes One to two feet of clearance for cable connections An operable network connection An asynchronous terminal or PC with terminal emulation so...

Страница 5: ...ansformer into an ac outlet D T E TERMINAL MANAGEMENT NETWORK POWER 496 15107 Power Jack Connecting the Terminal Port to an Async Terminal Procedure 1 Insert the 25 pin end of the EIA 232 cable into t...

Страница 6: ...he other end of the cable into the management interface connector This may be on A LAN adapter A UNIX workstation An external modem A router or server D T E TERMINAL MANAGEMENT NETWORK POWER 496 15108...

Страница 7: ...35 cable into the DTE connector D T E TERMINAL MANAGEMENT NETWORK POWER 496 15111 DTE DTE Port Connecting to the Network Procedure 1 Insert the 8 pin connector on the RJ48S network cable into the NET...

Страница 8: ...work is connected refer to Troubleshooting in Chapter 8 in the User s Guide 496 15073 Network System Port 56 64K C T S 1 0 6 O K A L A R M T E S T D M O O S O O F N S T X D 1 0 3 R X D 1 0 4 R T S 1 0...

Страница 9: ...r approvals on product Refer to the equipment s label for Certification Number Interface and Connectors 25 pin D subminiature connector 34 pin MS34 connector EIA 232 ITU V 24 ISO 2110 for Terminal and...

Страница 10: ...faces group DDS network DTE Data port Terminal port Management port H IP group H SNMP group H System group H TCP group H Transmission group DDS network DDS Enterprise MIB DTE Data port RS 232 Like MIB...

Страница 11: ...interfaces Locally through the Terminal port or by NMS connection through the Management port Remotely via Telnet session through the Management port or the In Band Management Channel IMC Out of band...

Страница 12: ...e 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a cert...

Страница 13: ...sing equipment regulations Cet appareil num rique de la classe A respecte toutes les exigences du r glement sur le mat rial brouilleur du Canada Government Requirements Certain governments require tha...

Страница 14: ...ational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the user s satisfa...

Страница 15: ...s in need of repair refer to the procedures described in the next section Warranty Sales and Service Information Contact your sales or service representative directly for any help needed For additiona...

Отзывы: