Monitoring the DSU

 4-7

7520-A2-GB20-20

May 1998

Viewing Network Performance Statistics

Performance statistics for the network interface are available to:

Monitor the current status of the network operations.

View the DSU’s performance statistics, which:

— Assist you in determining the duration of specific conditions.

— Provide a historical context for problem detection and analysis.

To view the Network Performance Statistics, follow this menu selection sequence:

Main Menu

Status

Network Performance Statistics

main/status/performance

Device Name:

Model: 7520

NETWORK PERFORMANCE STATISTICS

No Signal Count:

   101920

 26:33:08

Out of Service Count:

0

  0:00:00

Out of Frame Count:

  621

  8:53:49

Excessive BPV Count:

99830

144:28:11

Invalid BPV Count:

87409

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

ESC for previous menu

MainMenu

Exit

 Refresh

ClrStats

Î

Î

ÎÎ

ÎÎ

All counts show the number of occurrences since the last reset of the counters.

No Signal Count is the number of occurrences of a No Signal condition.

Out of Service Count is the number of occurrences of an Out of Service
(OOS) condition.

Out of Frame Count is the number of occurrences of an Out of Frame
(OOF) condition.

Excessive BPV Count is the number of times at least one invalid bipolar
violation was detected every 20 ms for a 2-second period.

Invalid BPV Count is a raw count of the number of invalid bipolar violations.

In the last column, 

hhh:mm:ss indicates the amount of time the condition has

existed in hours, minutes, and seconds. When the maximum time has been
exceeded, 255:59:59+ appears.

The screen appears with the cursor in the function area below the dotted line. To
update the performance statistics, select Refresh and press Enter.

Select ClrStats and press Enter to clear all statistics and refresh the screen.

Содержание 7520

Страница 1: ...MODEL 7520 DSU USER S GUIDE Document No 7520 A2 GB20 20 May 1998...

Страница 2: ...ke changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes Changes and enhancements to the product and to the infor...

Страница 3: ...Configurations 1 2 User Interfaces 1 3 Rear Panel Interfaces 1 4 2 Using the Asynchronous Terminal Interface Connecting to the Terminal Port 2 1 Initiating an ATI Session 2 2 Screen Format Types 2 3...

Страница 4: ...f Test Results 4 4 Test Status Messages 4 5 Viewing Network Interface Status 4 6 Viewing Network Performance Statistics 4 7 Monitoring the LEDs 4 8 System LEDs 4 9 Network LEDs 4 10 Port LEDs 4 11 5 T...

Страница 5: ...rview A 1 System Options Menu A 2 Network Interface Options Menu A 4 Data Port Options Menu A 5 Terminal Port Options A 8 B Worksheets Overview B 1 Configuration Worksheets B 1 C Cables and Pin Assign...

Страница 6: ...Contents iv 7520 A2 GB20 20 May 1998 This page intentionally left blank...

Страница 7: ...iguration Chapter 4 Monitoring the DSU Describes monitoring the DSU using the LEDs DSU status and network statistics Chapter 5 Testing Provides details about available tests and test setup Chapter 6 M...

Страница 8: ...epts and sections in alphabetical order Product Related Documents Document Number Document Title 7520 A2 GN10 Model 7520 DSU Startup Instructions Contact your sales or service representative to order...

Страница 9: ...ation Operates at 2 4 4 8 9 6 19 2 38 4 56 and 64 kbps full duplex as a limited distance modem Asynchronous Terminal Interface ATI Provides a menu driven VT100 compatible interface for configuring and...

Страница 10: ...the DSU at each location provide the LAN interconnection DDS Network 97 15084 02 DSU DSU Router Router The DSU can also be used in a Frame Relay network Frame Relay Network 97 15271 01 DSU DSU Router...

Страница 11: ...driven Asynchronous Terminal Interface ATI screens see Chapter 2 Using the Asynchronous Terminal Interface Front panel LED status indicators see Chapter 4 Monitoring the DSU 97 15786 Network System P...

Страница 12: ...shows the physical interfaces of the DSU Information about the installation of the DSU is contained in the Model 7520 DSU Startup Instructions 97 15781 RJ48S Jack NETW ORK TERMIN AL MANAGEMENT POW ER...

Страница 13: ...T100 compatible async terminal or a PC running emulation software The terminal or PC can be connected to the Terminal port directly or through an external modem Ensure that the device you connect comm...

Страница 14: ...st Configuration Control Ctrl a to access these functions Exit Entry to all of the DSU s tasks begins at the Main Menu screen which has four menus or branches Select To Status View results of diagnost...

Страница 15: ...pes of screen formats are available on the ATI Use the screen format To Menu selection Display a list of available functions for user selection Input Add or change information on a screen Input or edi...

Страница 16: ...a Port Options Screen function key area This is the area below the dotted line that lists function keys specific to the screen field value choices and system messages Menu Path Screen Function Keys Fi...

Страница 17: ...rsor to the previous field Spacebar Select the next valid value for the field Delete Del Delete character that the cursor is on Up Arrow or Ctrl u Move cursor up one field within a column on the same...

Страница 18: ...ssing the space bar to scroll through other valid values Screen Function Keys All screen function keys located below the dotted line operate the same way upper or lowercase throughout the screens For...

Страница 19: ...elect either the function s designated underlined character or press the tab key until you reach the desired function key Example To reset the Monitor 511 error counter to zero type r or R ResetMon 3...

Страница 20: ...to terminate the session Procedure To end an ATI session 1 Press Ctrl a to go to the screen function key area below the dotted line 2 Save changes if required A confirmation message appears if you hav...

Страница 21: ...VICE NAME Device Name Node A Clear System Name ________________________________________ Clear System Location ________________________________________ Clear System Contact ____________________________...

Страница 22: ...sible for the unit The maximum length of System Contact is 127 characters 5 Save the Device Name screen information as shown in the next section Saving Configuration Options When changes are made to t...

Страница 23: ...Configuration The DSU s active set of configuration options Default Factory Configuration A read only configuration area containing the factory default configuration options If the factory default se...

Страница 24: ...Customizing the DSU 3 4 7520 A2 GB20 20 May 1998 This page intentionally left blank...

Страница 25: ...and Status message on the last line of all screens Network Interface Status screen Network Performance Statistics screen LEDs on the ATI Status screen or the DSU s front panel Table 4 1 shows the ava...

Страница 26: ...rently active tests Refer to Table 4 4 Test Status Messages main status system Device Name Node A Model 7520 SYSTEM AND TEST STATUS HEALTH AND STATUS SELF TEST RESULTS TEST STATUS Cross Pair Detection...

Страница 27: ...are on and Network Performance Statistics are active 1 Verify that the remote site is in service 2 Contact network provider Out of Frame hhh mm ss1 DSU is detecting an out of frame condition associate...

Страница 28: ...are no status messages to display No action needed Self Test Results The results of the last power up or reset self test appear in the middle column of the System and Test Status screen Table 4 3 Sel...

Страница 29: ...on codes stop If the network service is 64 kbps CC the network loopback is latching This condition can only occur when the Network Interface option Network initiated DSU Loopback 64K CC is enabled Ref...

Страница 30: ...etwork interface status fields are read only Table 4 5 describes the contents of the Network Interface Status screen Table 4 5 Network Interface Status Screen Contents Field Status What the Status Ind...

Страница 31: ...menu MainMenu Exit Refresh ClrStats All counts show the number of occurrences since the last reset of the counters No Signal Count is the number of occurrences of a No Signal condition Out of Service...

Страница 32: ...terface Port LEDs display the activity on the selected user data DTE port To view the LED status screen follow this menu selection sequence Main Menu Status Display LEDs main status leds Device Name M...

Страница 33: ...work System Port red green yellow OK ON DSU is operational OFF DSU is performing a power up self test has detected a system failure or there is no power ALARM ON DSU has detected an alarm condition lo...

Страница 34: ...sending or receiving data or is in DMI condition all 1s being received OFF DDS network interface is receiving CMI codes OOS Out of Service ON DSU is receiving out of service code from the remote unit...

Страница 35: ...1s from the DTE Blinking User data is being transferred RXD Received Data ON Sending all 0s to the DTE OFF Sending all 1s to the DTE Blinking User data is being transferred RTS Request to Send ON DTE...

Страница 36: ...Monitoring the DSU 4 12 7520 A2 GB20 20 May 1998 This page intentionally left blank...

Страница 37: ...selection sequence Main Menu Test main test Device Name Model 7520 TEST Network Tests Data Port Tests Lamp Test Abort All Tests Ctrl a to access these functions Exit The DSU supports independent test...

Страница 38: ...oopback cannot be disabled by the user Local Loopback User DTE via CT141 Control via CT141 can be disabled Refer to Table A 3 Data Port Options Network initiated 2 4 56 kbps DSU Loopback Non latching...

Страница 39: ...SU Loopback Start Inactive 0 00 00 DSU Loopback Start Inactive 0 00 00 Send V 54 Up Send Inactive Send V 54 Down Send Inactive Send 511 Start Inactive 0 00 00 Monitor 511 Stop Active 125 08 48 Errors...

Страница 40: ...a CSU loopback 1 Position the cursor at the Start command next to CSU Loopback on the Network Tests screen 2 Press Enter 3 The Start command is changed to Stop If you want to manually stop the test ve...

Страница 41: ...DSU can send an ITU T V 54 Up or Down sequence to request the activation or termination of a DSU digital loopback of a remote unit This is the same as the DSU Loopback shown above except the test is...

Страница 42: ...of the test is displayed Procedure To run a Monitor 511 test 1 Position the cursor at the Start command next to Monitor 511 on the Network Tests screen 2 If desired use Ctrl a to switch to the screen...

Страница 43: ...Port Tests screen follow this menu selection sequence Main Menu Test Data Port Tests main test port Device Name Node A Model 7520 DATA PORT TESTS Test Command Status Result Local Loopback Start Inact...

Страница 44: ...hat the cursor is positioned at the Stop command 4 Press Enter The duration of the test is displayed DSU CSU DTE Interface Aggregate DDS Network Port 496 15145 DTE Port Local Loopback 511 Test Pattern...

Страница 45: ...ment to provide the clock for the 511 pattern on the interchange circuit CT113 TT for timing the incoming pattern Refer to V 35 User Data Port Connector in Appendix C Cables and Pin Assignments Runnin...

Страница 46: ...Test Timeout does not pertain to tests commanded by the Network such as the network initiated CSU and DSU Loopbacks DTE such as the DTE initiated Local Loopback On each test screen is a command colum...

Страница 47: ...e 6 1 Device Messages 1 of 2 Device Message What Message Indicates What To Do Command Complete Action requested has successfully completed No action needed Invalid Character x A nonprintable ASCII cha...

Страница 48: ...lected Wait until other test ends and message clears Abort all tests from the Test menu screen Stop the test from the same screen the test was started from Please Wait Command takes longer than 5 seco...

Страница 49: ...elf Test results The DSU detects an internal hardware failure Power the DSU off and on and try again Contact your service representative An LED is not lit LED is burned out Run the Lamp test If the LE...

Страница 50: ...3 in Appendix A Data Port Options is the same one that is physically connected to a DTE Run Loopback tests Refer to Running Network Tests in Chapter 5 Power Up Self Test fails Only Alarm LED is on af...

Страница 51: ...System System Options Table A 1 General system options Network Network Interface Options Table A 2 DDS network interface Data Port Data Port Options Table A 3 User data on DTE port Terminal Port Termi...

Страница 52: ...s set to DDS 2 4 to 56 2 4 to 56 kbps line rate 64CC 64 kbps Clear Channel on a 72 kbps circuit LADS Timing Possible Settings Internal External Receive Default Setting Internal Determines the timing s...

Страница 53: ...Tests must be terminated manually from the Network Tests screen Refer to Running Network Tests in Chapter 5 NOTE Tests commanded by the DTE or network initiated tests are not affected by this test tim...

Страница 54: ...a latching DSU loopback Disable DSU will not respond to a DSU loopback initiated by the network Data Scrambling 64K CC Possible Settings Enable Disable Default Setting Disable Determines whether data...

Страница 55: ...T103 Transmitted Data TXD The feature should be enabled when data errors are occurring due to long cable lengths Enable The DSU supplied clock is phase inverted with respect to the transmitted data TX...

Страница 56: ...ol Possible Settings Standard Follow RTS Forced On Circuit Assurance Short Delay Medium Delay Long Delay Default Setting Standard Specifies the operation of the Interchange Circuit CT106 Clear to Send...

Страница 57: ...he operation of the Interchange Circuit CT107 Data Set Ready DSR which is an output from the DSU Standard DSR is always asserted except when a DDS facility alarm is reported or the DSU is in Test mode...

Страница 58: ...e Provides automatic logoff of an ATI session through the Terminal Port When the session is closed User Interface Idle appears on the screen and the unit toggles the Terminal port DSR lead Enable The...

Страница 59: ...ion Worksheets System Configuration Option Settings Default in Bold Operating Mode DDS LADS DDS Line Rate Kbps 2 4 4 8 9 6 19 2 38 4 56 64CC LADS Timing Internal External Receive LADS Line Rate Kbps 2...

Страница 60: ...Both Bilateral Loopback Enable Disable Carrier Control by RTS Constant Switched CTS Control Standard Follow RTS Forced On Circuit Assurance RLSD Control Standard Forced On DSR Control Standard Forced...

Страница 61: ...signments C Overview The following sections provide pin assignments for the Terminal Port EIA 232 Connector EIA 232 User Data Port Connector V 35 User Data Port Connector Standard EIA 232D Crossover C...

Страница 62: ...ts to a PC or VT100 compatible terminal Signal Direction Pin Transmit Data TXD To DSU In 2 Received Data RXD From DSU Out 3 Request to Send RTS To DSU In 4 Clear to Send CTS From DSU Out 5 Data Set Re...

Страница 63: ...05 To DSU In 4 Clear to Send CTS 106 From DSU Out 5 Data Set Ready DSR 107 From DSU Out 6 Signal Ground Common 102 7 Received Line Signal Detector Carrier Detect RLSD CD 109 From DSU Out 8 Transmitter...

Страница 64: ...Set Ready DSR 107 From DSU Out E Received Line Signal Detector RLSD or LSD 109 From DSU Out F Data Terminal Ready DTR 108 1 2 To DSU In H Remote Loopback RL 140 To DSU In N Local Loopback LL 141 To DS...

Страница 65: ...nal modem Pin 1 Pin 14 Pin 13 Pin 25 Pin 1 Pin 14 Pin 13 Pin 25 P2 Plug Chassis Ground TXD RXD RTS DSR Signal Ground CD RLSD RXC DTR XTXC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...

Страница 66: ...work access is via a 14 foot modular cable with an RJ48S keyed plug connector on each end RJ48S DDS Network Interface Cable Functions Circuit Pin Transmitted data to the local loop R 1 Transmitted dat...

Страница 67: ...FCC Part 15 FCC Part 68 Safety Certifications Emissions Class A digital device Refer to the equipment s label for Registration Number Refer to the equipment s label for approvals on product Class A di...

Страница 68: ...DSU LADS Connection Distances Wire Diameter AWG Data Rate kbps 19 Gauge 0359 or 9122 mm 22 Gauge 0253 or 643 mm 24 Gauge 0201 or 511 mm 26 Gauge 0159 or 404 mm 2 4 20 0 mi 32 2 km 16 6 mi 26 7 km 12...

Страница 69: ...ng sent Communications port A computer s serial communications port used to transmit to and receive data from a DCE The DCE connects directly to this port Device software that sets specific operating...

Страница 70: ...tions simultaneously High Level Data Link Control A communications protocol defined by the International Standards Organization ISO A shared boundary between functional units International Telecommuni...

Страница 71: ...available routes An EIA standard for the 25 pin DCE DTE interface Same as EIA 232 Request to Send An EIA lead standard for V 24 circuit CT 105 an input signal DTE to DCE Receive To obtain transmitted...

Страница 72: ...ssary GL 4 7520 A2 GB20 20 May 1998 Wide Area Network A network that operates over long distances and spans a relatively large geographic area e g a country A random bit test 511 bytes in length WAN 5...

Страница 73: ...3 rear panel C 1 V 35 DTE C 4 Control menu 3 1 6 4 crossover EIA 232 cable C 5 CTS clear to send LED 4 11 Control option A 6 customer configuration areas 3 3 D data port options A 5 tests 5 7 Data Por...

Страница 74: ...s 2 5 L LADS Local Area Data Set example 1 2 maximum distances 1 2 Operating Mode setting A 2 LADS Line Rate Kbps System option A 2 LADS Timing System option A 2 lamp test 5 9 LEDs 4 8 4 11 front pane...

Страница 75: ...e 6 1 no data 6 3 6 4 R rear panel connections 1 4 reset device 6 4 revision numbers 6 4 RJ48S network interface cable C 6 RLSD Control option A 6 RTS Carrier Control option A 6 request to send LED 4...

Страница 76: ...3 Test menu 5 1 5 3 5 7 5 9 Test Timeout System option A 3 testing 4 1 5 1 timeout for ATI A 8 for tests A 3 Transmit Clock Data Port option A 5 troubleshooting 6 3 TXD transmitted data LED 4 11 user...

Отзывы: