Table 12.   Management and Communication – Communication Protocol

Configuration Options

Option

Factory 1

Factory 2

Comments/Description

Node IP Adr:

[Text Field]

[Text Field]

The IP address needed to access

Node IP Adr:

Clear

Clear

The IP address needed to access
the DSU/CSU.

Node Subnet Mask:

[Text Field]

[Text Field]

The Subnet Mask needed to

Node Subnet Mask:

Clear

Clear

The Subnet Mask needed to
access the device.

None

None

Com

Com

Default Network
Destination:

Aux

Aux

Specifies the default network
destination.

Destination:

FDL

FDL

destination.

EDL

n

EDL

n

Communications

[Text Field]

[Text Field]

The IP address for the COM port
when the Port Use configuration

Communications
Port IP Address:

Clear

Clear

p

when the Port Use configuration
option is set to Mgmt or Daisy.

Communication Port

[Text Field]

[Text Field]

The Subnet Mask needed to
access the device when the Port

Communication Port
Subnet Mask:

Clear

Clear

access the device when the Port
Use configuration option is set to
Mgmt or Daisy.

Com Link Protocol:

PPP

PPP

The link layer protocol for the COM
port when the Port Use

Com Link Protocol:

SLIP

SLIP

port when the Port Use
configuration option is set to Mgmt
or Daisy.

Auxiliary Port 

[Text Field]

[Text Field]

Specifies the alternate modem
Subnet Mask needed to access the
device when the Port Use

Auxiliary Port 
IP Address:

Clear

Clear

device when the Port Use
configuration option is set to Mgmt
or Daisy.

Auxiliary Port 

[Text Field]

[Text Field]

Specifies the Subnet Mask needed
to access the device when the Port

Auxiliary Port 
Subnet Mask:

Clear

Clear

to access the device when the Port
Use configuration option is set to
Mgmt or Daisy.

Содержание 3162

Страница 1: ...ACCULINK 3162 DSU CSU QUICK REFERENCE Document No 3162 A2 GL11 30...

Страница 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Страница 3: ...maintain competitive prices for our products Complete documentation for this product is available at www paradyne com Select Service Support Technical Manuals T1 E1 Digital Access Devices Select the...

Страница 4: ...o the T1 network using the appropriate cable Attach the 3162 DSU CSU to the customer premises equipment via the DTE DSX 1 and or port connectors 3 Power on the DSU CSU to perform the power up self tes...

Страница 5: ...ot work for you try the Factory 2 configuration for D4 framing format and AMI line coding format To further customize configuration options refer to Changing Configuration Options in Chapter 3 Operati...

Страница 6: ...System and Test Status Network Channel Display DTE Channel Display Port Assignment Display Network Sync Data Port Clear Statistics Network DTE Tests Sync Data Port Tests Device Tests Abort Tests Copy...

Страница 7: ...O 7 5 7 5 Provides Line Build Out in dB Line Build Out LBO 15 15 Provides Line Build Out in dB 22 5 22 5 Management Link Enable Enable Specifies whether the FDL s Management Link Disable Disable Speci...

Страница 8: ...99 Provides selectable extended DTE range capability 399 533 399 533 range capability 533 655 533 655 DTE LB on External Contact Enable Enable Allows control of DLB on external Contact Disable Disable...

Страница 9: ...ink Enable Enable Specifies whether the EDL Management Link is Enabled Invert Transmit Clock Enable Enable Selects phase inversion of the Clock Disable Disable Selects phase inversion of the transmit...

Страница 10: ...le Disable Specifies whether the device will maintain far end performance Performance Statistics Maint Maint p maintain far end performance statistics 10E 4 10E 4 10E 5 10E 5 Excessive Error Rate 10E...

Страница 11: ...28 896 784 960 840 1024 896 1088 952 1152 1008 1216 1064 1280 1120 1344 1176 1408 1232 1472 1288 1536 1344 64 56 128 112 192 168 256 224 320 280 384 336 448 392 512 448 576 504 640 560 704 616 768 672...

Страница 12: ...twork Network DTE DTE Selects the clock source to be Primary Clock Source Internal Internal Selects the clock source to be used as the master clock for the DSU CSU Source External External used as the...

Страница 13: ...2 2 the COM port Ignore Control Disable Disable Specifies whether the COM port Ignore Control Leads DTR DTR Specifies whether the COM port ignores DTR Password Required Enable Enable Controls whether...

Страница 14: ...rs to be used with the dial directory phone number Connect Indication Text Field Text Field Allows you to enter up to 20 characters used to determine Connect Indication String Clear Clear 20 character...

Страница 15: ...ifies whether a Telnet session disconnects after a certain period Inactivity Timeout Disable Disable p disconnects after a certain period of inactivity Disconnect Time 5 5 The period of inactivity 1 t...

Страница 16: ...nnect after a Trap Disconnect Disable Disable p connection will disconnect after a trap is sent Call Retry Enable Enable Specifies whether an outgoing call is retried on a busy or failed call Call Ret...

Страница 17: ...onfiguration option is set to Mgmt or Daisy Communication Port Text Field Text Field The Subnet Mask needed to access the device when the Port Communication Port Subnet Mask Clear Clear access the dev...

Страница 18: ...ccess to this device Name 2 Access Read Read The type of access allowed for Name 2 Access Read Write Read Write The type of access allowed for community name 2 Table 14 Management and Communication SN...

Страница 19: ...twork destination for Trap Manager n FDL FDL for Trap Manager n EDLn EDLn Disable Disable General Traps Warm Warm Specifies the general trap types to enable WarmStart Authentication General Traps Auth...

Страница 20: ...ed by the regulatory inspection authority for the installation site are the responsibility of the customer 7 When installed in the final configuration the product must comply with the applicable Safet...

Страница 21: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to...

Страница 22: ...y will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify the customer as soon as possible Also you...

Страница 23: ...e situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions...

Отзывы: