background image

12V

DC

Battery

+

-

Relay Module

N.O. N.C. C

+

_

+

-

24V

DC

Power supply

      (Max 28V)

~

~

16/24V

AC

Power supply

or

23

24 25

26 27

28

19 20

21 22

29 30

31 32

3

4

5

6

7

8

9

10 11 12

13 14 15

16 17 18

1

2

C

C

C

C

C

C

C

C

C

C

C

INPUT

INPUT

INPUT

INPUT

INPUT

INPUT

C

16 / 24 Vac

AUX

Zone Labels

Space is provided to label each zone.

Zone Connections

Connect detection devices 
as described in “Hardwired 
Zone Inputs” in the Imperial 
Reference and Installation 
manual.

Use 
supplied 
battery 
cable.

Detachable 
Terminals

Pry with 
screwdriver if 
necessary.

External Module
Tamper Switch

(N.C.)

The ZX32D 32-zone Expansion Module connects to the 
Imperial control panel’s Combus and acts as an interface 
between the control panel and any hardwired detection 
devices. The ZX32D also includes an external 16/24Vac 
or 24Vdc power supply input that can be used to power 
connected devices.

Compatibility

Installation

The ZX32D is a 
standard 35mm DIN 
rail module. Using the 
supplied DIN rail, the 
ZX32D can be 
mounted in any 
location. Alternatively, 
it can be mounted in 
a standard DIN rail 
enclosure. To attach 
the module, align the 
top of the DIN rail as 
shown in Figure 1 and apply pressure to the module until 
it clicks into place. To remove the ZX32D from a DIN rail, 
pull the release clip and remove the module.

To facilitate installation and servicing, the ZX32D 
terminals can be detached from the module. Wires can 
be labeled using the supplied tie wraps.

NOTE: The ZX32D does not support ATZ zone doubling.

Upgrading the Firmware

The ZX32D firmware can be upgraded through WinLoad 
using the CV4USB RS-485/RS-232 Converter. Refer to 
the firmware upgrade instructions found at: paradox.com 
- Software - WinLoad - Firmware Upgrade Instructions  

EVO48, EVO192 
DGP-848, DGP-NE96, EVO96

Figure 1: DIN Rail Mounting

Release 
clip

35mm 
DIN rail

LOC Button

The ZX32D LOC button is used to enter Test Mode (see page 2).

A Module Locate can  be performed using section [4002] (EVO) or [952] (DGP-48 
/ DGP-848). To end a module locate, press and hold LOC for 2 seconds.

Manual Controls

The ZX32D supplies 1A to power security system modules. By pressing the AUX 
button, the 13.8Vdc auxiliary power supply can be manually activated (LED green) 
or deactivated (LED off), allowing modules to be powered down without shutting 
down the control panel. If input power is lost, the AUX buttons will stop functioning. 
When power is restored, the button will resume its previous state.

ZX32D-EI01

PARADOX.COM

Printed in Canada - 11/2008 

Instructions

ZX32D 

32-Zone Expansion Module V1.0

Communication LED Feedback

BUS

RX 

(from panel)

TX 

(to panel)

Condition

green

green flash

green flash

OK (panel communication in progress)

red on 

off

off

Short on GRN or YEL

red on 

off

green

Communication failure / Too many 
modules on bus

red on

green

green

Bus lines reversed (GRN / YEL)

red flash  off

off

Bus power too low

red flash  green flash

green flash

Locate mode

blue flash  off

off

Firmware upgrade in progress

Power LED Feedback

LED

Colour

Condition

AC

green on

AC or DC power is supplied

CHRG green on

Battery is low / charging

BATT green on (less than 4 sec.) Battery test

Zone LED Feedback

LED

Status

off

zone closed

red

zone open

red flash

zone tamper

Отзывы: