Reference & Installation Manual
7
n
just moving the detector by a few inches can
greatly improve the reception. If the signal is still
weak, it is recommended that the detector be
moved to another location.
Alive Software
If the motion detector transmits two alarm signals
(LED on for 4 seconds) within a five minute
period, the detector will fall into Energy Save
mode where the detector will not transmit any
alarm signals for approximately 3 minutes. Due
to the motion detector’s Alive software, the red
LED continues to flash to indicate a detection
even when in Energy Save mode. Once the
three-minute Energy Save mode ends, the
detector will return to normal operation.
If the detector’s cover is removed and then
replaced while in Energy Save mode, the first
detection will trigger an alarm signal.
Technical Specifications
Sensor type:
Dual Element Infrared (x 2)
Sensor geometry:
Rectangular
Coverage:
11m x 11m (35ft x 35ft) 90°
viewing angle
Installation height:
2m to 2.7m (7ft to 9ft)*
Operating temperature: 0°C to +49°C (32°F to +120°F)
Animal immunity:
40kg (90lbs)
Power:
3 x “AA” alkaline batteries
RF frequency:
433
**
or 868
***
MHz
Lens:
2nd generation Fresnel lens,
LODIFF®, segments