background image

IMPORTANT INFORMATION

Limitation of liability

It is mandatory, 

Matri

x

2000

 panel to be installed in accordance with this manual, applicable codes, 

and the instructions of the Authority Having Jurisdiction. The manufacturer shall not under any cir-

cumstances be liable for any incidental or consequential damages arising from loss of property or 

other damages or losses owing to the failure of products beyond the cost of repair or replacement 

of any defective products. The manufacturer reserves the right to make product improvements and 

change product specifications at any time.

The manufacturer assumes no responsibility for errors or omissions, while every precaution has 

been taken during the preparation of this manual to ensure the accuracy of its contents.

Warranty

PARADOX FIRE warrants its products to be free from defects in materials and workmanship under 

normal use for a period of two (2) years (the “Warranty Period”) from the production-delivery date, 

identified by date code(s) indicated on the products. Because PARADOX FIRE does not install or 

connect the products and because the products may be used in conjunction with products not man-

ufactured by PARADOX FIRE, PARADOX FIRE cannot guarantee the performance of the fire alarm 

system and shall not be responsible in any way whatsoever for faulty installation or connection.

RoHS directive compliance

The EC RoHS guideline has been released in order to reduce the heavy metal load in 

electrical and electronic products caused by e.g. lead and mercury. All manufacturers 

are obligated to provide only RoHS-compliant products to the European market, effective 

from July 1st, 2006.
PARADOX  FIRE  hereby  states  that 

Matri

x

2000 

panel  is  fully  compliant  with  RoHS 

2002/95/EC directive.

Disposal of your old appliance

1. When this crossed-out wheeled bin symbol is attached to a product it means the prod-

uct is covered by the European Directive 2002/96/EC.
2. All electrical and electronic products should be disposed of separately from the mu-

nicipal waste stream via designated collection facilities appointed by the government or 

the local authorities.
3. The correct disposal of your old appliance will help prevent potential negative conse-

quences for the environment and human health.
4. For more detailed information about disposal of your old appliance, please contact 

your city office, waste disposal service or the shop where you purchased the product.

Содержание Matrix2000

Страница 1: ...Matrix2000 User Guide CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones Version 2 0 Revision 0 2 ...

Страница 2: ... be used in conjunction with products not man ufactured by PARADOX FIRE PARADOX FIRE cannot guarantee the performance of the fire alarm system and shall not be responsible in any way whatsoever for faulty installation or connection RoHS directive compliance The EC RoHS guideline has been released in order to reduce the heavy metal load in electrical and electronic products caused by e g lead and m...

Страница 3: ...ral Fault 5 2 3 1 SIGNALING DEVICE fault 6 2 3 2 EARTH fault 6 2 3 3 AUX POWER Fault 6 2 4 Zone Fault indications 6 2 5 System ALARM indication 7 2 6 Zones ALARM indications 7 3 Central Electric Keyswitch 8 4 Controls Via Keypad 9 4 1 System SILENCE key 9 4 2 System TEST key 9 4 3 System RESET key 9 4 4 Zones BYPASS keys 9 TABLE OF CONTENTS ...

Страница 4: ...ications and the simple controls of the Matrix2000 panel ensure the easy handling and controlling of the system by the operator 2 Keyboard Indications and Controls Operating monitoring and programming of the panel is performed in three different ac cess levels Access to level 2 is achieved by the keyswitch on the face of the panel Figure 1 Operations at access level 2 are performed with the silico...

Страница 5: ...e Battery wear increased internal resistance of batteries 2 2 System FAULT indication General Fault GENERAL FAULT indicates a problem in the system It turns ON in case of Zone wiring connection problems Signalling devices output wiring problems Relays outputs wiring problems auxiliary relays MER4 or MER8 Auxiliary power faults Earth fault condition The above mentioned problems could be open circui...

Страница 6: ...ll stop functioning If more than 1 Amp is required a compatible EN 54 4 approved fire alarm power supply must be used When such a power supply is used the 24 OUT connection of the panel must be connected to the negative terminal of the auxiliary power supply 2 4 Zone Fault indications The Zone Fault indications will blink in a different pattern Figure 2 page 6 depending on the type of the problem ...

Страница 7: ...ored Software Watchdog The Matrix2000 panel contains a watchdog circuit that will activate when the micropro cessor is either faulty or unable to execute the programmed firmware Upon detection the Fault relay the on board sounder and the fault indicator on the user interface are all activated 2 5 System ALARM indication When the system detects a condition of fire smoke high temperature etc the pan...

Страница 8: ...tral electric Keyswitch has three positions 1st position Access Level 1 Normal This is the Normal operation mode The panel waits for alarm events or any faults that may develop in the installation All buttons on the silicon rubber keypad are disabled 2nd position Access Level 2 Control Enable Alarm events and possible faults are detected all buttons on the silicon rubber keypad are active and the ...

Страница 9: ... are used to prevent the corresponding zone from causing an alarm Note that zone disablements must not be a permanent working condition and they must be used only as a temporary action For example zone bypassing can be used in case of building maintenance or other activities that can trigger false alarms on the detectors Bypassing a zone is achieved by positioning the keyswitch in the Control Enab...

Страница 10: ...t button 1 RESPONDING TO TROUBLE SIGNALS Turn the keyswitch of the keyboard to Con 1 trol Enable Silence the panel buzzer 2 Investigate the cause of the trouble and 3 notify the authorized service personnel im mediately TO SILENCE THE PANEL BUZZER Press Panel Silence 1 The buzzer turns OFF Any new events turn the buzzer back on Trouble conditions not cleared resound the buzzer after a predetermine...

Страница 11: ..._______________________________________________________ Zone 12 ______________________________________________________________________ Zone 13 ______________________________________________________________________ Zone 14 ______________________________________________________________________ Zone 15 ______________________________________________________________________ Zone 16 ____________________...

Страница 12: ...Document Part Number MATRIX UG01 CPD version 2 0 revision 0 2 November 2010 ...

Отзывы: