Programming Guide
Zone Timers
[705]
General Zone Options 1
Option
OFF
ON
[1]
ATZ zone doubling
Disabled
N
Enabled
[2]
ATZ wiring options
Series
N
Parallel
[3]+[4]
Tamper Recognition
[5]
Generate tamper on bypassed zone
N
No
Yes
[6]+[7]
Supervision Options
[8]
N/A
N/A
N/A
[706]
General Zone Options 2
Option
OFF
ON
[1]
N/A
N/A
N/A
[2]
EOL resistors
Disabled
N
Enabled
[3]
N/A
N/A
N/A
[4]
ZX8 ID (Panel + 1) Input 1
Zone input
N
Tamper input
[5]
ZX8 ID (Panel + 9) Input 1
Zone input
N
Tamper input
[6]
ZX8 ID (Panel + 17) Input 1
Zone input
N
Tamper input
Section E55 E65
Data
Description
(Default
060)
[041]
Zone 1
(Z1):
(Z1):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 1 Speed
[042]
Zone 2
(Z2):
(Z2):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 2 Speed
[043]
Zone 3
(Z3):
(Z3):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 3 Speed
[044]
Zone 4
(Z4):
(Z4):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 4 Speed
[045]
Zone 5
(Z1 with ATZ):
(Z5):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 5 Speed
[046]
Zone 6
(Z2 with ATZ):
(Z6):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 6 Speed
[047]
Zone 7
(Z3 with ATZ):
(Z7):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 7 Speed
[048]
Zone 8
(Z4 with ATZ):
(Z8):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 8 Speed
[049]
Zone 9
N/A
(Z9):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 9 Speed
[050]
Zone 10
N/A
(Z1 with ATZ):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 10 Speed
[051]
Zone 11
N/A
(Z2 with ATZ):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 11 Speed
[052]
Zone 12
N/A
(Z3 with ATZ):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 12 Speed
[053]
Zone 13
N/A
(Z4 with ATZ):
____/____/____
(000 to 255) x 10ms
Hardwire Zone 13 Speed
Keypad Bus Tamper Recognition Options*
Keypad / Bus Module Tamper Recognition Options*
[3]
[4]
OFF
OFF
Disabled Disabled
OFF
ON
Trouble only
Trouble only
ON
OFF
When disarmed:
TROUBLE
ONLY
When armed: Follow zone’s alarm type
Trouble only
ON
ON
When disarmed:
AUDIBLE
ALARM
When armed: Follow zone’s alarm type
Audible alarm
* Tamper recognition of keypad / bus module only if section
[700]
option
[7]
is enabled.
Keypad Bus Module Supervision Options
[6]
[7]
OFF
OFF
Disabled
OFF
ON
Trouble only
ON
OFF
When disarmed:
TROUBLE
ONLY
When armed: Follow zone’s alarm type
ON
ON
When disarmed:
AUDIBLE
ALARM
When armed: Follow zone’s alarm type