Esprit E55 / E65
29
Zone shutdown (##)
1 57A - Zone bypass
Zone tampered (##)
1 144 - Sensor tamper
Zone tamper restore (##)
3 144 - Sensor tamper restore
AC failure
1 3A1 - AC loss
Battery failure
1 3A9 - Battery test failure
Auxiliary supply trouble
1 3AA - System trouble
Bell output current limit
1 321 - Bell 1
Bell absent
1 321 - Bell 1
Clock lost
1 626 - Time/date inaccurate
Fire loop trouble
1 373 - Fire trouble
Communication fail
1 354 - Communication fail
RF jamming
1 344 - RF receiver jam detection
TLM trouble restore
3 351 - Telco 1 fault restore
AC failure restore
3 3A1 - AC loss restore
Battery failure restore
3 3A9 - Battery test restore
Auxiliary supply trouble restore
3 3AA - System trouble restore
Bell output current limit restore
3 321 - Bell 1 restore
Bell absent restore
3 321 - Bell 1 restore
Clock programmed
3 625 - Time/date reset
Fire loop trouble restore
3 373 - Fire trouble restore
Fail to communicate with monitoring station
3 354 - Fail to communicate
RF jamming
3 344 - RF receiver jam detection
Combus fault
1 333 - Expansion module failure
Module tamper
1 341 - Expansion module tamper
Bus fault restore
3 333 - Expansion module failure restore
Module tamper restore
3 341 - Expansion module tamper restore
Cold start
1 3A8 - System shutdown
Test report engaged
1 6A2 - Periodic test report
PC software communication finished
1 412 - Successful - download access
Installer on site
1 627 - Program mode entry
Installer programming finished
1 628 - Program mode exit
Maintenance in
1 627 - Program mode entry
Maintenance out
1 628 - Program mode exit
Closing delinquency
1 654 - System inactivity
Module AC fail
1 342 - AC failure on module
Module AC fail restore
3 342 - AC restored on module
Module battery fail
1 338 - Battery failure on module
Module battery fail restore
3 338 - Battery failure on module
RF Module low battery
1 384 - RF transmitter low battery
RF Module battery restore
3 384 - RF transmitter battery restore
RF Module supervision trouble
1 381 - Loss of supervision - RF
RF Module supervision restore
3 381 - Supervision restore - RF
RF Module supervision lost
1 381 - Loss of supervision- RF
RF Module supervision restore
3 381 - Loss of supervision- RF restore
RF Module tamper
1 145 - Expansion module tamper
RF Module tamper restore
3 145 - Expansion module tamper restore
Paramedic alarm
1 1AA - Medical
Zone forced
1 57A - Zone forced
Zone included
3 57A - Zone included
System Event