All report codes are assigned to a system account, whether or not partitioning is activated. Arm/disarm
reports are assigned to System "A" when partitioning is "off", or to the system account to which they
belong, based on code priority assignment, when partitioning is activated. Trouble and special report
codes are always assigned to System "A".
Zones 10 to 24 are not available on the 738 EXPRESS.
Arming codes/disarming codes:
(Addresses 300-399)
SECTION 11 - 35
System access codes can be programmed to generate hexa report codes that communicate the identity of the
user arming/disarming the control panel to the central monitoring station. Each user code can be assigned an
arm/disarm report code.
Auto/Espload Arm will be reported to the central when Espload is used to arm the
control panel or when the system arms itself automatically (on “no movement” or at a specified time).
Espload
disarm will be reported to the central when Espload is used to disarm the control panel. Arm/disarm with mas-
ter code will be reported to the central when the master code or keyswitch is used to arm/disarm control panel.
Zone alarm codes:
(Addresses 400-423)
SECTION 36 - 41
Alarm report codes programmed will be sent to the monitoring station, identifying the zones that are gen-
erating alarms. Note that the 738 has 14 “alarm” zones and the 738 EXPRESS has only 9 “alarm” zones.
See the “Programming Guides” for the 738 and 738 EXPRESS.
Zone restore codes:
(Addresses 424-447)
SECTION 42 - 47
Zone restoration codes programmed will be sent to the monitoring station, identifying zones returning to
normal status after alarms. Note that the 738 has 14 “restore” zones and the 738 EXPRESS has only 9
“restore” zones. See the “Programming Guides” for the 738 and 738 EXPRESS.
Shutdown codes:
(Addresses 448-471)
SECTION 48-53
These codes are sent to the monitoring station to identify zones bypassed during “auto zone shutdown”
(address 086, [
TRBL
]). Note that the 738 has 14 “shutdown” zones and the 738 EXPRESS has only 9
“shutdown” zones. See the “Programming Guides” for the 738 and 738 EXPRESS.
Tamper trouble codes:
(Addresses 472-495)
SECTION 54-59
These codes identify zone locations of tamper “troubles” to the central. If ATZ (738 only) is activated, the
tamper zone location reported represents a pair of zones. Note that the 738 has 6 “tamper” zones and the
738 EXPRESS has 7 “tamper” zones. See the “Programming Guides” for the 738 and 738 EXPRESS.
Trouble codes:
(Addresses 496-503)
SECTION 60 - 61
6 trouble status codes can be reported to the central, if programmed: max. auxiliary current, bell discon-
nect/max. bell current, battery disconnected/low voltage, power failure, fire loop trouble, and timer loss. (See
"Trouble Display/Monitoring", page 27-28, for a list of trouble conditions displayed on the keypad.)
Trouble restore codes:
(Addresses 504-511)
SECTION 62 - 63
If trouble conditions occur and are reported, once normal status is re-established, a "restoration" code
can be transmitted to the central to indicate that the "trouble" situation has been rectified.
Note: All Tamper/Wire Faults must be restored before a “Tamper/Wire Fault” restoration code is transmitted.
Special codes:
(Addresses 512-527)
SECTION 64 - 67
These codes are assigned to report 11 special status conditions.
Test report
Test report will be reported to the central automatically at the day and time set for the
“auto test report” (addresses 046, 047, 048) or manually. To send a manual test report,
press [
ENTER
], followed by installer, master or user code 1, and [
BYP
] are pressed.
Panic 1
Panic alarm will be reported to the central if PS1 is used or if keys [1] and [3] are pressed
for 2 seconds.
Panic 2
Panic alarm will be reported to the central if keys [4] and [6] are pressed for 2 seconds.
Panic 3
Panic alarm will be reported to the central if keys [7] and [9] are pressed for 2 seconds.
Late to close
Will be reported to the central when the system has been armed or not by the required time.
No movement
Will be reported to the central when there is no movement in the protected area for a
designated time period.