Key = off:
Disabled.
Note:
When keypad zone supervision is activated, keypad zones
should not be assigned
24 hour definition.
Address 32, key [4]
KEYPAD CLOCK MODE
Key = on:
Keypad clock runs independently.
Key = off:
Keypad clock is refreshed by the panel (available
only on control panel software version 0.98 onward.)
Address 32, key [5]
VIEW EVENT LIST MODE
Key = off:
Event list for control panel software versions prior
to 2.00.
Key = on:
Event list for control panel software versions
2.XX.
When scrolling through the events on this list, the first event
which appears is the most recent. Information displayed
includes event name, event number, time and day.
In normal mode, pressing
[
MEM
]
, followed by
[
ENTER
]
switches
the system to view event list mode. The display will indicate:
Event/Event number/Day/Time ex:
ALARM
01A / 001 Sun :52
.
Press
[
ENTER
]
once to advance to next event. At the end of
event list, system will revert to normal mode. To exit view
event list mode at any time, press
[
CLEAR
]
. If
DAY
00:00
appears and the display automatically advances to the end of
the event list buffer, no more events are stored in memory.
Press
[
CLEAR
]
to exit immediately.
IM640
14
Important: If timer lost message appears in the display, the time
and day indicated may not be accurate. If the time was repro-
grammed following power loss, all messages displayed
before
reset timer loss message contain the correct time and day.
Address 34 Installer Keypad Lockout
To protect installer-programmed information in the 640 keypad
from unauthorized or accidental modification, enable the Installer
Keypad Lockout feature. When enabled, only individuals pos-
sessing the new Installer Keypad Programming code can gain
access to keypad programming mode. To erase programmed
information, enter programming address
34
and disable the
Installer Keypad Lockout feature. At address
34
, the message
KEYPAD LOCK
,
PRESS
1, 4, 6
will appear in the LCD display.
Installer Keypad Lockout is
enabled
only when keys
[1]
,
[4]
and
[6]
are on (lit) at address
34
. If any other combination of
lighted/ unlighted keys is entered at this address, the Installer
Keypad Lockout feature is
disabled.
If installer keypad lockout is disabled, installer-programmed
data can be erased in the following manner:
1. Place a jumper across the two pins on the bottom left
side of the back of the LCD keypad circuit board (to
the left of the bottom corner of the processor chip.)
2. Disconnect keypad from its power source.
3. Restore power to the keypad.
4. Remove jumper.
IM640