MEM
]
Panel time
and
clear "trouble 8"
(all 3 codes)
Key
[
MEM
]
flashes.
Á
Enter two digits (00 to 23) for hours
+ 2 digits (00 to 59) for minutes. (Press
[
ENTER
].
)
À
[
BYP
]
Test report
(all 3 codes)
Reporting is enabled at address
206
keys
[11]
,
[12]
. A
value must be entered at address
175
, and both tele-
phone and account numbers must be programmed.
[
TRBL
]
Call Espload via telephone
(all 3 codes)
Panel and PC ID numbers (addresses
001
-
004
) and PC
download phone number (addresses
060
-
067
) must be
programmed.
[
AWAY
]
Answer Espload
(all 3 codes)
This feature is available when using the ADP-1 adapter.
In Espload, "blind dial" must be activated in "modem
setup" section, and panel phone number programmed
(works also without ADP-1).
[
STAY
]
Cancel communication attempts
(master code and user 1 can only stop calls from/to
Espload), (installer code - all communications)
[
STAY
]
Reset to default panel settings
(installer code only)
(This feature is available only on control panel software
versions prior to 2.00.) Connect reset jumper. Press
[
ENTER
]
and installer code, followed by
[
STAY
]
. Remove
reset jumper.
À
Control panel software versions prior to 2.00.
Á
Control panel software versions 2.00 and beyond.
IM640
18
Power supply failure
If
[
TRBL
]
key flashes in normal mode, this indicates a power
supply failure. Display will alternate between :
SYSTEM TROUBLE
/
POWER SUPPLY
and the system status message.
Note: On control panel software versions 0.98 onward, trouble
memory mode is no longer available (Flashing
[
TRBL
]
key indi-
cates the presence of
active
trouble conditions.)
The Esprit Model 640 LCD Keypad is compatible with all Esprit
Series 8 control panels batch code
079
onward.
IM640
19